Toroidal Power Transformer for Amplifiers
1. Installation:
Horizontal (non-conventional-type base plate), sunk, side type, and bridge.
2. Application:
Especially low-hum and low-dispersing construction
Low-level of induction
High-grade design casing possible
Statically shield winding and magnetical shield winding optional.
3. Equipment:
Over 50 sets toroidal/annular/ ring coil winding machines, 3 EI type transformer lines, 2 sets of vacuum annealing furnaces, A set of nitrogen and hydrogen production equipment.
4. Warning
Under no circumstances should both ends of the fixing bolt simultaneously contact the metal chassis or framework as this would create a potentially dangerous 'shorted-turn'.
5. Certificate
The certificate of our transformer has CE CQC RoHS UL
6. Note
The above-mentioned toroidal transformer is frequently-used, we can also manufacture the products by customer design. And the specification is for reference, if has the change further, please take the material object as the standard.
| 20VA |
Φ60 |
H25 |
82 |
10mA |
1.20V0.45kgs |
| 30VA |
Φ65 |
H35 |
84 |
10mA |
1.200.50kgs |
| 50VA |
Φ70 |
H40 |
88 |
20mA |
1.151.30kgs |
| 100VA |
Φ85 |
H60 |
90 |
30mA |
1.151.50kgs |
| 120VA |
Φ90 |
H75 |
93 |
40mA |
1.102.00kgs |
| 200VA |
Φ110 |
H80 |
93 |
100mA |
1.102.80kgs |
| 300VA |
Φ120 |
H80 |
94 |
150mA |
1.083.50kgs |
| 500VA |
Φ130 |
H80 |
94 |
150mA |
1.085.00kgs |
| 800VA |
Φ140 |
H85 |
94 |
200mA |
1.086.50kgs |
| 1000VA |
Φ140 |
H85 |
95 |
300mA |
1.058.50kgs |
| 1500VA |
Φ160 |
H90 |
95 |
400mA |
1.0512.0kgs |
| 2000VA |
Φ180 |
H90 |
95 |
400mA |
1.0515.0kgs |
| 4000VA |
Φ220 |
H95 |
95 |
500mA |
1.0520.0kgs |
| 6000VA |
Φ250 |
H95 |
95 |
500mA |
1.0525.0kgs |
Other supplier products
|
|
RCI-601P Power Testing system Electric Cable Fault location |
1.1FUNCTION FEATHER:
lCompass display: to display pipe position and left-right direction directly.
lRight/wrong indication: measure the pipe curren... |
|
|
50Hz Power Supply Toroidal Transformer for Television |
We have passed ISO9001:2015,CE,SGS approval and IEC report
1.Technical parameters
Power
Input Voltage(V)
Output Volta... |
|
|
Grewin 50-400 Hz PBT or ABS instrument transformers for Relay protection device |
Features:
Low cost
Water proof
More than 10 outline size
5.0,1.0Aac secondary ratios available
Applications:
Current,Power,Energy monitoring dev... |
|
|
Toroidal Power Transformer for Lighting Transformer |
We have passed ISO9001:2015,CE,SGS approval and IEC report
1.Technical parameters
Power
Input Voltage(V)
Output Volta... |
|
|
PCB Mouting Electrical Encapsulated Transformer |
1.Product Specification:1). Models:EI28, EI30, EI35, EI41, EI57, EI66, EI86, EI96, EI105, EI114, EI133, EI152, EI162 etc.2). Maximum output: 1.2W, ... |
All supplier products
Same products