How to calculate the calorific value of transformer

How to calculate the calorific value of transformer

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.


Send product request

To: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

What\'s the transformer for?
What\'s the transformer for? Transformer is the core of power equipment, such as3 phase power transformer,which is closely related to people's production and life. It is made b...
Characteristics and properties of amorphous alloy transformer
Characteristics and properties of amorphous alloy transformer is a new type of energy saving transformer made of a new magnetic conducting material (amorphous alloy). It is more than 70% lower than the no-loa...
What Is Unexcited Voltage Regulation Of Transformer?
What Is Unexcited Voltage Regulation Of Transformer? What is the unexcited voltage regulation of transformer? Let's take a look.Following shared fromOil Immersed Transformersupplier. Non-field exci...
S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer
S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power transformer,3 phase step down transformer S13 series of Three-phase oil Immersed Transformers,three phase transformer,three phase variable transformer,3 phase transformer,three phase power ...
Fixed mounted Switchgear
Fixed mounted Switchgear Low Voltage Switchgear High and Low Voltage Switchgears GGD series low voltage switchgearis used for power lighting Product Description GGD series ...
All supplier products

Same products

TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER Seller: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER Seller: Jiangsu Acrel Electrical Manufacturing Co., LTD. PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane...