(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre OpticsApplicationsThese cables are used for laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in the outer interstices.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/336.739.723203×25+3×50/340.643.628603×35+3×25/340.543.528603×35+3×50/342.345.332203×50+3×25/343.846.835003×50+3×50/343.846.836503×70+3×35/347.050.043603×70+3×50/349.753.750103×95+3×50/352.256.255503×120+3×70/355.959.966903×150+3×70/361.065.080303×185+3×95/364.068.093203×240+3×120/372.176.1119603×300+3×150/377.381.3142606/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/339.042.025203×25+3×50/341.444.429303×35+3×25/341.844.829803×35+3×50/343.646.633503×50+3×25/345.148.136403×50+3×50/345.148.137803×70+3×35/348.351.345003×70+3×50/348.351.347303×95+3×50/353.557.557103×120+3×70/357.261.268603×150+3×70/362.366.382103×185+3×95/365.369.395103×240+3×120/373.477.4121703×300+3×150/378.682.6145008.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/342.545.528503×25+3×50/344.247.232103×35+3×25/345.348.333403×35+3×50/345.348.334803×50+3×25/349.453.441803×50+3×50/349.453.443203×70+3×35/352.756.750903×70+3×50/352.756.753103×95+3×50/357.061.061603×120+3×70/362.166.175503×150+3×70/365.769.787103×185+3×95/368.772.7100203×240+3×120/376.880.8127503×300+3×150/382.086.01511012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/345.548.531503×25+3×50/345.548.533003×35+3×25/348.351.336603×35+3×50/348.351.338003×50+3×25/352.556.545403×50+3×50/352.556.546803×70+3×35/355.759.754603×70+3×50/355.759.756903×95+3×50/361.465.467703×120+3×70/365.169.179803×150+3×70/368.772.791703×185+3×95/373.277.2107803×240+3×120/379.883.8132803×300+3×150/386.391.31607014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/350.354.337503×25+3×50/350.354.339003×35+3×25/353.157.142903×35+3×50/353.157.144303×50+3×25/356.360.350203×50+3×50/356.360.351603×70+3×35/361.065.061903×70+3×50/361.065.064103×95+3×50/365.369.373403×120+3×70/369.073.085803×150+3×70/374.078.0100503×185+3×95/377.081.0114303×240+3×120/385.090.0144003×300+3×150/390.295.21686018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/353.757.741603×25+3×50/353.757.743003×35+3×25/356.660.647303×35+3×50/356.660.648703×50+3×25/361.265.257003×50+3×50/361.265.258403×70+3×35/364.468.466803×70+3×50/364.468.469003×95+3×50/368.772.778603×120+3×70/373.877.893903×150+3×70/377.581.5106603×185+3×95/380.584.5120603×240+3×120/388.593.5150903×300+3×150/394.799.717820
Other supplier products
|
|
3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power Control Cables (Radial Field) |
3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These mediu... |
|
|
Belden8102 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8102ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
300/500V Mica+XLPE Insulated, LSZH Sheathed Power Cables (2-4 Cores) |
300/500V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (2-4cores)(CU/MGT+XLPE/LSZH 300/500V Class 2)Application:The cable... |
|
|
Belden9736 |
Multipair Individually Screened Cables-Belden Equivalent 9736ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
XHH / XHHW-2 |
UL Industrial Cables XHH / XHHW-2Application and DescriptionThe XHH conductor is suitable for most current wiring solutions for residential,Website... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |