Fire Resistant Central Loose Tube Optical Fiber Cables
Fire Resistant Central Loose Tube Optical Fiber CablesApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship where low smoke,Website:, halogen free and fire resistant cables are required to increase safety on board, suitable for flexible installation on and below deck of commercial ships without constant exposure to oil, grease and other lubricants.StandardsIEC 60092-350/351/352/353/359/370/376IEC 60332-1-2IEC 60332-3-22IEC 60754-1/2IEC 61034IEC 60331-11 and -25ConstructionOptical FiberLoose tube, gel filled.Inner TapeFire protection tape.Outer TapeFire protection tape.Outer SheathSHF1.Fiber SpecificationG50/125G62.5/125E9/125Geometry/Mechanical PropertiesCore Diameterμm50 μ 2.562.5 μ 3Mode Field Diameter (at 1310 nm)μm9.2 μ 0.4Cladding Diameterµm125 μ 2125 μ 1125 μ 2Coating Diameterµm245 μ 10245 μ 5245 μ 10Core Non-circularity%< 5< 5Cladding Non-circularity%< 1< 1< 1Core/Clad Concentricity Errorµm< 1.5< 1.5< 0.8Eccentricity of Coatingµm< 10< 10< 10Screen Test≥100 kpsi≥100 kpsi≥100 kpsiTransmission PropertiesOM2OM1OS1WavelengthnmAttenuation Max.dB/km2.70.83.20.90.360.22Bandwidth Min.MHz. kmEffective Group of Refraction1.4831.4781.4971.4931.46951.4701Numerical Aperture0.200 μ 0.0150.275 μ 0.015Dispersion Coefficient Max.ps/nm.km3.518Zero Dispersion Wavelengthnm1300–1322Dispersion Slopeps/nm² .km≤0.092Cutoff Wavelength (cabled)nm≤1250Polarization Mode Dispersionps/km1/2≤0.1Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 20×ODTemperature Range: -20℃ ~ +60℃Dimensions and WeightPart No.No. of Optical FibersNominal Overall Diameter mmNominal Weight kg/kmUE092-FCLA-X-12-H-J1210.0115UE092-FCLB-X-24-H-J2410.5125Note: X: Fiber type (0=Fiber and copper conductors in cable 4=50/125 multi-mode fiber (OM3); 5=50/125 multi-mode fiber (OM2); 6=50/125 multi-mode fiber (OM1); 7=NZDS SM fiber per G.656.; 8=NZDS SM fiber per G.655.; 9=Standard SM fiber per G.652.D)
Other supplier products
|
S12 RU(c) 250 V NEK606 Cable |
S12 RU(c) 250 V EPR insulation,Website:, SHF2 sheathed NEK606 Instrument cableApplications :These unarmoured cables are flame retardant, low smoke ... |
|
Flame Retardant RS485 Databus Cables PVC Sheath |
Flame Retardant RS485 Databus Cablespplication:The cables are designed for RS485 data connections where continued functionality is required during ... |
|
Single Core Cables To IEC 60502 |
Single Core Medium Cable to IEC 60502-2
Application:
... |
|
XHHW/CPE, 600V, Type TC |
UL Industrial Cables XHHW/CPE,Website:, 600V, Type TC Control CableApplication and DescriptionXHHW/CPE type TC Control Cable is for use in industri... |
|
Fire Resistant RS485 Databus Cables |
Fire Resistant RS485 Databus Cables Application:The cables are designed for RS485 data connections where continued functionality is required during... |
All supplier products
Same products
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |