.

600/1000V LSZH Sheathed, Armoured (multicore)

600/1000V LSZH Sheathed,Website:, Armoured ((multicore) Application:This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors.Standard:Basic design to IEC 60502-1; BS 6724FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING 600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound. Inner Sheath(optional): LSZH Compound Armouring(optional): Galvanized Steel Wire Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIES Temperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5s max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. Weightmm²No./mmmmmmkg/kmmmmmmmkg/km5x1.57/0.530.711.31849.90.914.54027x1.57/0.530.712.422511.20.916.049010x1.57/0.530.715.632514.31.2520.076112x1.57/0.530.716.237014.81.2520.582719x1.57/0.530.719.051617.41.624.0118627x1.57/0.530.722.771221.31.628.1153737x1.57/0.530.725.594123.91.630.7185648x1.57/0.530.729.0118627.51.634.622765x2.57/0.670.712.823711.20.915.84967x2.57/0.670.713.830312.40.917.260210x2.57/0.670.717.542615.91.2521.894312x2.57/0.670.718.148916.51.2522.4102019x2.57/0.670.721.372519.91.626.7149827x2.57/0.670.725.5100423.91.630.9193337x2.57/0.670.728.7133426.91.633.9237248x2.57/0.670.732.9170631.32.039.632525x47/0.850.714.232412.61.2518.27127x47/0.850.715.542214.11.2519.887110x47/0.850.719.759718.51.2524.4121312x47/0.850.720.369019.11.625.7146219x47/0.850.724.0103722.61.629.4193127x47/0.850.728.8144527.21.634.4253237x47/0.850.732.5193231.12.039.3344848x47/0.850.737.3247935.72.044.24273Note : Other conductor sizes & core confi gurations are available upon request.Electrical PROPERTIES Conductor Operating Temperature : 90°CAmbient Temperature : 30°CUnarmoured Current-Carrying Capacities (Amp)Conductor cross- sectional areaReference method 4 (enclosed in conduit in thermally insulating wall etc)Reference method 3 (enclosed in conduit on a wall or in trunking etc)Reference method 1 (clipped direct)Reference method 11 (on a perforated cable tray, horizontal or vertical)Reference method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm²AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Size of conductor2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..Armoured  Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm²AAAAAAAA1..Voltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531.031.027.031.025.02.519.019.016.019.015.0412.012.010.012.09.7


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Belden28538
Belden28538 Multicore Unscreened Armoured Cables-Belden Equivalent 28538ApplicationsThese multicore unscreened armoured cables are Type MC Metal Clad cables.Co...
Belden9736
Belden9736 Multipair Individually Screened Cables-Belden Equivalent 9736ApplicationsThese cables have individually screened pairs laid up. Each individually s...
NHXMH/(N)HXMH(St)
NHXMH/(N)HXMH(St) German Standard Industrial Cables NHXMH/(N)HXMH(St)Application and DescriptionNHXMH cable is halogen free intended for fixed installation in dry an...
S10 IYOI(c) 60 V NEK606 Cable
S10 IYOI(c) 60 V NEK606 Cable S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel...
300/500V Mica+XLPE Or SR Insulated Overall Screened Armoured Fire Resistant Instrumentation Cables
300/500V Mica+XLPE Or SR Insulated Overall Screened Armoured Fire Resistant Instrumentation Cables 300/500V Mica+XLPE or SR Insulated & Overall screened Armoured fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/L...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes