Three Core Cables To VDE 0276

Three Core Medium Power Cable to VDE 0276Application:The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations,Website:, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.Standards:DIN VDE 0276 Part 620 -622HD 620 S1Conductor:Stranded compacted circular copper or aluminium conductors according to IEC60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383. All internal interstices of the conductor are filled with water blocking compound to prevent ingress of water through conductor during storage, handing, installation and operation of the cable.Conductor Screen:The conductor screen consists of an extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation to exclude all air voids. The screen has a minimum thickness of 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C.Insulation:Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1 with high degree of cross-linking, free from contaminants, air voids and heat resistant by dry cured process.The nominal insulation wall thickness is shown in table 1.Table 1.Insulation Thickness  Nom. Cross-Section AreaInsulation Thickness at Nom. Voltage3.6/6kV (Um=7.2)kV6/10KV (Um=12KV)8.7/15KV (Um=17KV)12/20KV (Um=24KV)18/30KV (Um=36KV)mm2mmmmmmmmmmXLPEXLPEXLPEXLPEXLPE352.53.44.55.5-502.53.44.55.58.0702.53.44.55.58.0952.53.44.55.58.01202.53.44.55.58.01502.53.44.55.58.01852.53.44.55.58.02402.63.44.55.58.03002.83.44.55.58.04003.03.44.55.58.0Insulation Screen: The insulation screen consists of extruded non metallic, semi-conducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. The minimum thickness is 0.3mm and the maximum volume resistivity of 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. Conducting Water Blocking Layer: The insulation screen may be covered by semi- conductive water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness. Metallic Screen: Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm is applied helically with overlap. Total cross section of metallic screen layer is shown in table 2. The screen can withstand of fault current to earth of 1000 A for one second at maximum temperature of 160°C. Minimum cross section of concentric conductor is according to DIN VDE 0273 & 0276 as shown. Table 2. Minimum Total Cross Section of Metallic ScreenNominal Cross-Section Area Of CableMinimum Cross-Section of Metallic ScreenDC Resistance of the Copper Wire Screenmm²mm²mmUp to 120161....35Separator / Water Blocking Layer:The metallic screen may be covered by non-conducting water blocking tape which will swell up under the influence of moisture of water to ensure longitudinal watertightness. Separation Sheath (for armoured cable):The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour. Thickness of separation sheath is shown in table 3. Table 3. Separation Sheath ThicknessCores DiameterApprox.Thickess of Inner Sheathmmmm><< p=""><35451.445601.660801.880-2.0Armour(for armoured cable): The armour consists of: 1) Double layers of galvanized steel tape are applied helically with proper inner overlapping over an extruded separation sheath. Thickness of the steel tape is shown in table 4. Tabel 4. Galvanized Steel Tape ThicknessInner DiameterThickness of Galvanized Steel Tapemmmm><< p=""><-300.230700.570-0.82) Galvanized flat steel wires with thickness of 0.8 mm are applied helically over the surface of inner sheath with minimum of 90% coverage. And galvanized Steel tape with nominal thickness of 0.3 mm is applied helically with 50% coverage to cover the surface of the flat wires. Outer Sheath:Overall sheath comprises a layer of extruded PE compound DMP2 according to HD620.1 and 2YM3 type to DIN VDE 0276 Part 3, or PVC compound DMV6 according to HD620.1 and YM5 to DIN VDE 0276 Part 6. Normal wall thickness is 2.5mm (1/500mm 18/30sq 2.6mm), suitable for exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable. PHYSICAL PROPERTIES: Operating Temperature: up to 90°C Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath ) Short Circuit Temperature: 250°C (short circuit duration up to 5 seconds) Bending Radius: 15 x OD (Cable without metal sheath) 30 x OD (Cable with aluminium sheath) Table 5. Nominal /Operating /Testing VoltagesNominal Voltage Uo/UOperating Voltage (Um)Testing Voltage3.6/6KV8KV12.5KV6/10KV12KV21KV8.7/15KV18KV30.5KV12/20KV24KV42KV18/30KV36KV63KVMedium Voltage Cables to VDE 0276TYPE CODES:ConductorN According to VDE Standard (No abbreviation for copper conductor) A Aluminium conductorCopper conductorInsulation2X XLPEScreenCConcentric conductor of copperCE Concentric conductor of copper over each individual coreSScreen of copper wires & copper tape,helically woundSE Screen of copper wires over each individual cores(G) Longitudinally waterproofArmourF Armour of galvanized flat steel wireG Counter Helix of galvanized steel tapeB Steel tape armouringR Armour of galvanized round steel wireSheath2Y PEY PVC H LSZHK Lead sheathKL Aluminium sheathThree Core 3.6/6KV (Um=7.2KV)N2XSEYNA2XSEYDimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlMm2mmmmmmmm2mmmmmmkg / kmkg / km256.052.50.11612.51..102.50.11613.51..252.50.11614.71..902.50.11616.31..72.50.11618.11..12.50.11619.51..32.50.12520.71..32.50.12522.71..72.60.12525.31..92.80.12527.92..73.00.13531.12.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 3.6/6KV (Um=7.2KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm²mmmmmmmm²mmmmmmmmkg / kmkg / km256.052.50.11612.50.52..102.50.11613.50.52..252.50.11614.70.52..902.50.11616.30.52..72.50.11618.10.52..12.50.11619.50.52..32.50.12520.70.52..32.50.12522.70.82..72.60.12525.30.83..92.80.12527.90.83..73.00.13531.10.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 3.6/6KV (Um=7.2KV) Galvanized Flat Steel wire+Steel Tape Armoured Cables Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm²mmmmmmmm²mmmmmmkg / kmkg / km256.052.50.11612.51..102.50.11613.51..252.50.11614.71..902.50.11616.31..72.50.11618.11..12.50.11619.51..32.50.12520.71..32.50.12522.71..72.60.12525.31..92.80.12527.92..73.00.13531.12.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 3.6/6KV (Um=7.2KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km256.052.50.11612.50.52..102.50.11613.50.52..252.50.11614.70.52..902.50.11616.30.52..72.50.11618.10.52..12.50.11619.50.52..32.50.12520.70.52..32.50.12522.70.82..72.60.12525.30.83..92.80.12527.90.83..73.00.13531.10.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 3.6/6KV (Um=7.2KV) Galvanized Flat Steel wire+Steel Tape Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km256.052.50.11612.50.82..102.50.11613.70.82..252.50.11614.70.82..902.50.11616.30.82..72.50.11618.10.82..12.50.11619.50.82..32.50.12520.70.82..32.50.12522.70.82..72.60.12525.30.83..92.80.12527.90.83..73.00.13531.10.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical DataNom. Cross- Section AreaD C Resistance CU / ALA C Resistance CU / ALShort Circuit Rating of Conductor CU / AL 1 secCapacitanceCharging CurrentShort Circuit Rating of Copper Wire Screen Per Core 1 secShort Circuit Rating of Copper Tape Screen Per Core 1 secReactanceInductancemm2μΩ/mμΩ/mkApF/mmA/mkAkAμΩ/mnH/m25727/1200927/15383.6/2.32720.332.60./868668/11135.0/3.23010.362.60./641494/8226.8/4.43320.402.60./443343/5689.8/6.33830.462.60./320248/41013.3/8.54320.522.60./253196/32517.2/11.04740.572.60./206159/26521.2/13.55110.614.30..1/164128/21126.6/17.05620.674.30..4/12598/16134.9/22.36020.724.30..1/10080/13043.8/28.06220.754.31..0/77.864/10257.3/36.66480.785.81.180250Three Core 6/10KV (Um=12KV) N2XSEY NA2XSEY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmkg / kmkg / km256.053.40.11614.31..103.40.11615.31..253.40.11616.51..903.40.11618.11..73.40.11619.91..13.40.11621.31..33.40.12522.51..33.40.12524.51..73.40.12526.92..93.40.12529.12..73.40.13531.92.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 6/10KV (Um=12KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg/kmkg/km256.053.40.11614.30.52..103.40.11615.30.52..253.40.11616.50.52..903.40.11618.10.52..73.40.11619.90.52..13.40.11621.30.52..33.40.12522.50.53..33.40.12524.50.53..73.40.12526.90.53..93.40.12529.10.53..73.40.13531.90.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 6/10KV (Um=12KV) Galvanized Flat Steel wire Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km256.053.40.11614.30.82..103.40.11615.30.82..253.40.11616.50.82..903.40.11618.10.82..73.40.11619.90.82..13.40.11621.30.82..33.40.12522.50.83..33.40.12524.50.83..73.40.12526.90.83..93.40.12529.10.83..73.40.13531.90.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical DataNom. Cross- Section AreaD C Resistance CU / ALA C Resistance CU / ALShort Circuit Rating of Conductor CU / AL 1 secCapacitanceCharging CurrentShort Circuit Rating of Copper Wire Screen Per Core 1 secShort Circuit Rating of Copper Wire Screen Per Core 1 secReactanceInductancemm2μΩ/mμΩ/mkApF/mmA/mkAkAμΩ/mnH/m25727/1200927/15383.6/2.32040.432.60./868668/11135.0/3.22370.472.60./641494/8226.8/4.42600.522.60./443343/5689.8/6.32980.602.60./320248/41013.3/8.53340.672.60./253196/32517.2/11.03650.732.60./206159/26521.2/13.53920.784.30..1/164128/21126.6/17.04300.864.30..4/12598/16134.9/22.34760.954.30..1/10080/13043.8/28.05241.054.31..0/77.864/10257.3/36.65801.165.81.181260Three Core 8.7/15KV (Um=17.5KV) N2XSEY NA2XSEY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmkg / kmkg / km256.054.50.11616.51..104.50.11617.51..254.50.11618.71..904.50.11620.31..74.50.11622.11..14.50.11623.51..34.50.12524.71..34.50.12526.72..74.50.12529.12..94.50.12531.32..74.50.13534.12.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 8.7/15KV (Um=17.5KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km256.054.50.11616.50.52..104.50.11617.50.52..254.50.11618.70.52..904.50.11620.30.52..74.50.11622.10.52..14.50.11623.50.53..34.50.12524.70.53..34.50.12526.70.53..74.50.12529.10.53..94.50.12531.30.53..74.50.13534.10.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 8.7/15KV (Um=17.5KV) Galvanized Flat Steel Wire Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km256.054.50.11616.50.82..104.50.11617.50.82..254.50.11618.70.82..904.50.11620.30.82..74.50.11622.10.82..14.50.11623.50.83..34.50.12524.70.83..34.50.12526.70.83..74.50.12529.10.83..94.50.12531.30.83..74.50.13534.10.83.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical Data Nom. Cross- Section Area D C Resistance CU / ALA C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 secCapacitance Charging CurrentShort Circuit Rating of Copper Wire Screen Per Core 1 secShort Circuit Rating of Copper Tape Screen Per Core 1 secReactanceInductancemm2μΩmμΩ/mkApF/mmA/mkAkAμΩmnH/m25727/1200927/15383.6/2.31760.482.60./868668/11135.0/3.21930.532.60./641494/8226.8/4.42110.582.60./443343/5689.8/6.32400.652.60./320248/41013.3/8.52670.732.60./253196/32517.2/11.02910.792.60./206159/26521.2/13.53120.854.30..1/164128/21126.6/17.03400.934.30..4/12598/16134.9/22.33751.024.31..1/10080/13043.8/28.04111.124.31..0/77.864/10257.3/36.64541.245.81.284270Three Core 12/20KV (Um=24KV) N2XSEY NA2XSEY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmkg / kmkg / km357.105.50.11619.71..255.50.11620.91..905.50.11622.51..75.50.11624.31..15.50.11625.72..35.50.12526.92..35.50.12528.92..75.50.12531.32..95.50.12533.52..75.50.13536.32.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 12/20KV (Um=24KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom.  Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km357.105.50.11619.70.52..255.50.11620.90.52..905.50.11622.50.53..75.50.11624.30.53..15.50.11625.70.53..35.50.12526.90.53..35.50.12528.90.53..75.50.12531.30.83..95.50.12533.50.83..75.50.13536.30.84.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 12/20KV (Um=24KV) Galvanized Flat Steel Wire Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmMm2mmmmmmmmkg / kmkg / km357.105.50.11619.70.82..255.50.11620.90.82..905.50.11622.50.83..75.50.11624.30.83..15.50.11625.70.83..35.50.12526.90.83..35.50.12528.90.83..75.50.12531.30.83..95.50.12533.50.83..75.50.13536.30.84.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical Data Nom. Cross- Section AreaD C Resistance CU / AL A C Resistance CU / AL Short Circuit Rating of Conductor CU / AL 1 secCapaci- tance Charging CurrentShort Circuit Rating of Copper Wire Screen Per Core 1 secShort Circuit Rating of Copper Tape Screen Per Core 1 sec Reactance Inductancemm2μΩ/mμΩ/mkApF/mmA/mkAkAμΩ/mnH/m35524/868668/11135.0/3.21680.672.60./641494/8226.8/4.41830.732.60./443343/5689.8/6.32070.832.60./320248/41013.3/8.52290.922.60./253196/32517.2/11.02491.002.60./206159/26521.2/13.52661.064.31..1/164128/21126.6/17.02891.164.31..4/12598/16134.9/22.33181.274.31..1/10080/13043.8/28.03481.394.31..0/77.864/10257.3/36.63881.535.81.387280Three Core 18/30KV (Um=36KV)N2XSEY NA2XSEY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmkg / kmkg / km508.258.00.11625.92..908.00.11627.52..78.00.11629.32..18.00.11630.72..38.00.12531.92..38.00.12533.92..78.00.12536.32..98.00.12538.52..78.00.13541.32.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard Three Core 18/30KV (Um=36KV) Galvanized Steel Tape Armoured Cables N2XSEYBY NA2XSEYBY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km508.258.00.11625.90.53..908.00.11627.50.53..78.00.11629.30.53..18.00.11630.70.83..38.00.12531.90.83..38.00.12533.90.83..78.00.12536.30.84..98.00.12538.50.84..78.00.13541.30.84.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Three Core 18/30KV (Um=36KV) Galvanized Flat Steel wire Armoured Cables N2XSEYFGbY NA2XSEYFGbY Dimensional DataNom. Cross- Section AreaApprox. Conductor DiameterNom. Insulation ThicknessCopper Tape ThicknessCopper Wire Screen Area*Approx. Insulation DiameterNom. Armour ThicknessNom. Sheath ThicknessApprox. Overall DiameterApprox. WeightCuAlmm2mmmmmmmm2mmmmmmmmkg / kmkg / km508.258.00.11625.90.83..908.00.11627.50.83..78.00.11629.30.83..18.00.11630.70.83..38.00.12531.90.83..38.00.12533.90.83..78.00.12536.30.84..98.00.12538.50.84..78.00.13541.30.84.*Optional wire screen can be provided in combination of copper tapes. Nominal screen area, as stated in the table, can be supplied as standard. Electrical DataNom. Cross- Section AreaD C Resistance CU / ALA C Resistance CU / ALShort Circuit Rating of Conductor CU / AL 1 secCapacitanceCharging CurrentShort Circuit Rating of Copper Wire Screen Per Core 1 secShort Circuit Rating of Copper Tape Screen Per Core 1 secReactanceInductancemm2μΩ/mμΩ/mkApF/mmA/mkAkAμΩ/mnH/m50387/641494/8226.8/4.41420.852.61./443343/5689.8/6.31590.952.61./320248/41013.3/8.51751.052.61./253196/32517.2/11.01891.132.61./206159/26521.2/13.52011.214.31..1/164128/21126.6/17.02171.34.31..4/12598/16134.9/22.32371.424.31..1/10080/13043.8/28.02581.554.31..0/77.864/10257.3/36.62821.695.81.596290Current Rating for Three Core 1.8/3KV(Um=7.2KV ) to 26/35KV(Um=42KV) XLPE InsulationUnarmoredArmoredNom. Cross- Section AreaBuried direct in GroundLaid in Single Way DuctLaid in AirBuried direct in GroundLaid in Single Way DuctLaid in AirCUALCUALCUALCUALCUALCUALmm2AAAAAACurrent Rating for Three Core 1.8/3KV(Um=7.2KV ) to 26/35KV(Um=42KV) XLPE InsulationUnarmoredArmoredNom. Cross- Section AreaBuried direct in GroundLaid in Single Way DuctLaid in AirBuried direct in GroundLaid in Single Way DuctLaid in AirCUALCUALCUALCUALCUALCUALmm2AAAAAA


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

NHXMH/(N)HXMH(St)
NHXMH/(N)HXMH(St) German Standard Industrial Cables NHXMH/(N)HXMH(St)Application and DescriptionNHXMH cable is halogen free intended for fixed installation in dry an...
Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381
Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381 Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for use on longwall shearers,We...
XLPE Insulated, LSZH Sheathed And Overall Screened, Armoured Instrumentation Cables (Single Pair)
XLPE Insulated, LSZH Sheathed And Overall Screened, Armoured Instrumentation Cables (Single Pair) XLPE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2X(St)HSWAH 90°C / 300VSTANDARDSBasic de...
0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables
0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power Control Cables 0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control CablesApplication:These fire resistant elastomeric in...
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808 XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes