.

PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multitriple)

PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Triple)RE-2Y(St)H 90°C / 300 VSTANDARDSBasic design to  EN50288-7APPLICATION:These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire,  these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation  cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply.With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ;CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ;CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil ResistanceICEA S-73-532**Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min. 60% of elongation.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:PE compound, EN 50290. 2-23.Triple:Three conductors twisted to form a tripleLay-up:Triples laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or Blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +90°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2Y(St)HNo. of Triplesx3xCross SectionNominalInsulationThicknessNominalOuter SheathThicknessNominalOverallDiameterApprox.WeightNo.x3xmm²mmmmmmkg/kmRE-2Y(St)H 1T0.51x3x0,500.350.85.449RE-2Y(St)H 1T0.751x3x0,750.380.96.160RE-2Y(St)H 1T1.01x3x1.00.40.96.671RE-2Y(St)H 1T1.31x3x1,30.450.97.286RE-2Y(St)H 1T1.51x3x1,50.450.97.597Note : Other conductor sizes & core configurations are available upon requestElectrical PROPERTIESConductor Area Sizemm²0.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20°C)Ω/km36.725.018.514.212.3Insulation resistance (20°C)MΩ.km(Min.Mutual Capacitance (1 kHz)pF/m(Max.Capacitance unbalance(1 kHz)pF/500 m (Max.)00000InductancemH/km(Max.)11111L / R (ratio) (max.)μH/Ω2525254040Operating voltageV300Test Voltage UrmsCore to CoreVCore to ScreenV


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Belden8307
Belden8307 Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8307ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl...
Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Sheath, 8kV To ICEA S-75-381
Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Sheath, 8kV To ICEA S-75-381 Portable Arc-Welding Cable 600V ICEA S-75-381ApplicationsThese cables are designed for useas flexible welding leads connecting the electrode holder...
Type SHD-PCG Three-Conductor Portable Power Cable 2kV ICEA S-75-381
Type SHD-PCG Three-Conductor Portable Power Cable 2kV ICEA S-75-381 Type SHD-PCG Three-Conductor Portable Power Cable 2kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for use on longwall shearers,We...
450 750V XLPE Insulated, PVC Sheathed, Screened Power Cables (Multicore)
450 750V XLPE Insulated, PVC Sheathed, Screened Power Cables (Multicore) 450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl...
600 1000V XLPE Insulated, PVC Sheathed, Screened Power Cables (3C+3E)
600 1000V XLPE Insulated, PVC Sheathed, Screened Power Cables (3C+3E) 600/1000V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (3C+3E)CU/XLPE/CUTO/PVC 600/1000V Class 2Application:The cables are designed...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes