FDT-1371 Automatic Water Titrator
FDT-1371 Automatic Water Titrator
Specifications
It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.
Purpose:
FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.
Features
1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;
2, with the trial date, clock and other parameters prompts;
3, differential detection, automatic correction system deviation;
4, the mixing, detection, print data microcomputer automatically completed;
5 ug water and ppm units automatically converted;
6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;
Technical parameters
Measuring range: 3μg ~ 100mg
2, electrolytic speed: 2.4 mg / min (max)
3 Resolution: 0.1μg
4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)
5, end of show: information display, buzzer indicator endpoint
6, showing the clock: year, month, day, hour minute second (retentive)
7, printer: 44 mm wide and 16 character dot matrix printing paper
8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%
9. Size: 290×380×120 (mm);
10. Weight: 9 Kg;
FDT-1371 Automatic Water Titrator
Specifications
It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.
Purpose:
FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.
Features
1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;
2, with the trial date, clock and other parameters prompts;
3, differential detection, automatic correction system deviation;
4, the mixing, detection, print data microcomputer automatically completed;
5 ug water and ppm units automatically converted;
6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;
Technical parameters
Measuring range: 3μg ~ 100mg
2, electrolytic speed: 2.4 mg / min (max)
3 Resolution: 0.1μg
4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)
5, end of show: information display, buzzer indicator endpoint
6, showing the clock: year, month, day, hour minute second (retentive)
7, printer: 44 mm wide and 16 character dot matrix printing paper
8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%
9. Size: 290×380×120 (mm);
10. Weight: 9 Kg;
Send product request
Other supplier products
| FDH-0301 Fuel Oil Oxidation Stability Tester thin oxygen | Technical Specifications Gasoline engine oil thin oxygen oxidation stability analysis based SH/T0074 design and manufacturing. Function Features 1,... | |
| Automatic benzene distillation range tester FDS-0571 | Automatic benzene distillation range tester FDS-0571 Application range The benzene distillation range meter applicable standard: GB/T3146 Feature... | |
| Extreme pressure lubricant oxidation characteristics analyzer FDH-0401 | Application range Extreme pressure lubricant oxidation characteristics analyzer applicable standards: SH/T0123 Sample at 95 ° C under constant ... | |
| Transformer Oil Oxidation Stability Tester FDH-1001 | Transformer Oil Oxidation Stability Tester FDH-1001 Application range Transformer Oil Oxidation Stability Tester SH/T0206-92 "transformer oil oxid... | |
| Automatic saturation vapor pressure tester (Reid method) FDR-0231 | Application range The automatically Reid method saturated vapor pressure tester is designed and manufactured to the requirements specified in the n... |