FDT-1371 Automatic Water Titrator
FDT-1371 Automatic Water Titrator
Specifications
It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.
Purpose:
FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.
Features
1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;
2, with the trial date, clock and other parameters prompts;
3, differential detection, automatic correction system deviation;
4, the mixing, detection, print data microcomputer automatically completed;
5 ug water and ppm units automatically converted;
6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;
Technical parameters
Measuring range: 3μg ~ 100mg
2, electrolytic speed: 2.4 mg / min (max)
3 Resolution: 0.1μg
4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)
5, end of show: information display, buzzer indicator endpoint
6, showing the clock: year, month, day, hour minute second (retentive)
7, printer: 44 mm wide and 16 character dot matrix printing paper
8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%
9. Size: 290×380×120 (mm);
10. Weight: 9 Kg;
FDT-1371 Automatic Water Titrator
Specifications
It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.
Purpose:
FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.
Features
1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;
2, with the trial date, clock and other parameters prompts;
3, differential detection, automatic correction system deviation;
4, the mixing, detection, print data microcomputer automatically completed;
5 ug water and ppm units automatically converted;
6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;
Technical parameters
Measuring range: 3μg ~ 100mg
2, electrolytic speed: 2.4 mg / min (max)
3 Resolution: 0.1μg
4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)
5, end of show: information display, buzzer indicator endpoint
6, showing the clock: year, month, day, hour minute second (retentive)
7, printer: 44 mm wide and 16 character dot matrix printing paper
8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%
9. Size: 290×380×120 (mm);
10. Weight: 9 Kg;
Send product request
Other supplier products
| FDH-0901 Heating Oil Oxidation Stability Tester | Technical Specifications Heating Oil Oxidation Stability Tester for the detection of heat treatment oil oxidation stability.Heating Oil Oxidation S... | |
| Auto paraffin light stability analyzer FDS-1201 | Automatic the paraffin light stability analyzer FDS-1201 Application range Paraffin Light Stability Tester applicable standards: SH/T0404 The i... | |