Fast thermal conductivity tester
Fast thermal conductivity tester-Mainly used for the determination of non-metallic solid material thermal conductivity, suitable for testing units, universities, research and production units to use.
Standards compliant:
GB 10297-1998, GB / T10294-2008, GB / T10801.1, GB / T10801.2
GB 10297-1998, GB / T10294-2008, GB / T10801.1, GB / T10801.2
TheFast thermal conductivity testermain parameters:
1. Power supply: AC220V ± 10%, 50Hz
2. Temperature range: (0-80) ℃
3. Temperature resolution: 0.01 ℃
4. Temperature measurement accuracy: 0.1 ℃
5. Thermal conductivity measurement range: ≤ 2W / (m · K)
6. Measurement error: ± 5%
7. Maximum measurement time: 300s
8. Laboratory temperature: (23 ± 2) ° C
9. Laboratory humidity: (40-60%) RH
2. Temperature range: (0-80) ℃
3. Temperature resolution: 0.01 ℃
4. Temperature measurement accuracy: 0.1 ℃
5. Thermal conductivity measurement range: ≤ 2W / (m · K)
6. Measurement error: ± 5%
7. Maximum measurement time: 300s
8. Laboratory temperature: (23 ± 2) ° C
9. Laboratory humidity: (40-60%) RH

Fast thermal conductivity testerMain features:
1. Measurement time is short: the measurement process, the specimen material denatured, deformation is small, the measured value closer to the true value;
2. Easy to operate: all the use of microcomputer intelligent control, the operator without special training, you can directly post operation;
3. Wide test range: the basic effective coverage of non-metallic materials and low thermal conductivity of the metal material;
4. Widely used: widely used in construction, energy, environmental protection, chemical, medical, energy and other industries.
1. Measurement time is short: the measurement process, the specimen material denatured, deformation is small, the measured value closer to the true value;
2. Easy to operate: all the use of microcomputer intelligent control, the operator without special training, you can directly post operation;
3. Wide test range: the basic effective coverage of non-metallic materials and low thermal conductivity of the metal material;
4. Widely used: widely used in construction, energy, environmental protection, chemical, medical, energy and other industries.
Send product request
Other supplier products
| Multi Finger Scratch/Mar Tester | Introduction: Multi Finger Scratch/Mar Tester uses tungsten carbide as a scratch to accurately detect surface damage caused by unconventiona... | |
| Horizontal flame test chamber | The Horizontal Flammability Tester is designed for determining the comparative burn rates and burn resistance of textiles, particularly those for a... | |
| Bally Type testing Flexometer | Bally Type Flexometer 6-12-24 Working Places Standards: EN ISO 20344:6.6, I.U.P.10+20, I.U.P.20, UNI 4818, DIN 53.351, UNE/I.U.P.20 Applicatio... | |
| N95 Face Mask Material Meltblown Nonwoven Fabric Particle Filtration Efficiency (PFE) Tester | N95 Face Mask Material Meltblown Nonwoven Fabric Particle Filtration Efficiency (PFE) Tester is applicable to the performance verification of new ... | |
| ISO 22612 Dry microbial penetration resistance tester | The resistance to dry microbial penetration test (ISO 22612) evaluates resistance characteristics of protective equipment to dry bacteria-carrying ... |
Same products
| Blanket Flammability Test Machine | Seller: Standard Groups | Bed Blanket Flammability Tester-It is mainly used for testing the flame retardant performance of ... | |
| High Temperature Oxygen Index Tester | Seller: Standard Groups | The High-Temperature Oxygen Index (TOI) measuring instrument determines oxygen index at up to 125... | |
| Limiting Oxygen Index Tester | Seller: Standard Groups | The Limiting Oxygen Index Tester measures the minimum oxygen concentration needed to sustain comb... | |
| Vertical Flammability Tester | Seller: Standard Groups | Vertical Flammability Chamber for measuring the vertical flame spread for children’ sleepwe... | |
| 45 Degree Flammability Tester | Seller: Standard Groups | Application 45 Degree Flammability Tester is used to determine the burning characteristics of te... |