GB/T 19666 Toxicity Index Tester,combustion gas toxicity tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The GB/T 19666 Toxicity Index Tester is a specialized instrument designed for evaluating the toxicity of combustion gases generated from flame-retardant and fire-resistant wires, cables, and optical cables. Based on controlled thermal decomposition or combustion in a tube furnace, the system introduces a defined flow of smoke into standard absorption solutions or gas sampling bags for subsequent quantitative analysis. The tester is widely applied in smoke toxicity assessments required by railway, cable, and fire safety standards, providing reliable data to support material safety evaluation under fire conditions.

Application

The GB/T 19666 Toxicity Index Tester is used for smoke toxicity testing in accordance with multiple international and regional standards. Typical application scenarios include:

Flame-retardant and fire-resistant power cables

Railway rolling stock cables and signal cables

Optical fiber cables and communication cables

Polymer insulation and sheath materials

Halogen-containing and halogen-free cable compounds

The instrument supports both absorption-liquid analysis and gas bag collection methods, allowing flexible downstream analysis depending on the test standard and laboratory requirements.

Standards

The system complies with the following standards and test methods:

(1) GB/T 19666 – General Rules for Flame-Retardant and Fire-Resistant Wires, Cables or Optical Cables

(2) EN 50305 – Railway Applications – Test Methods for Fire Behaviour of Electric Cables

(3) BS 6853 Annex B – Code of Practice for Fire Precautions in the Design and Construction of Passenger Carrying Trains

(4) ISO 19700 – Controlled Equivalence Ratio Method for the Determination of Toxic Product Yields in Fire Effluents (Steady-State Tube Furnace Method)

Parameters

ItemSpecification
Tube furnace heating length 600 mm
Temperature range 0–1100 °C
Temperature accuracy ±0.1 °C
Quartz tube Heat-resistant quartz, thickness ≥ 2 mm
SO₂ measurement range 0–1000 ppm
SO₂ resolution 1 ppm
SO₂ accuracy ±30 ppm
NOₓ measurement range 0–3000 ppm
NOₓ resolution 1 ppm
NOₓ accuracy ±30 ppm
Gas sampling bag PTFE-coated, 80 L capacity, with imported manual sampler
CO measurement range 0–10 %
CO resolution 0.01 %
CO accuracy Absolute ±0.1 % or relative ±3 %
CO₂ measurement range 0–20 %
CO₂ resolution 0.01 %
CO₂ accuracy Absolute ±0.2 % or relative ±3 %
Spectral analysis device Spectrometer at 500 nm wavelength, membrane thickness 10 mm
Absorption solution 0.1 N NaOH
Titration reagents Picric acid aqueous solution (3 g/dm³) and sodium carbonate aqueous solution (50 g/dm³)

Features

Sealed chamber design with the smoke generation system installed internally, providing stable operation and effective protection of core components

Large observation window allowing clear visual monitoring of test status and specimen movement

Integrated industrial design with panel-mounted structure, offering intuitive operation and ergonomic user interface

Tube furnace protected by perforated outer housing to enhance heat dissipation and ensure uniform temperature rise to the target value

High-temperature K-type thermocouple for accurate measurement of specimen zone temperature

Ceramic combustion boat driven by strong magnetic coupling and transmission mechanism for stable and repeatable specimen delivery into the furnace core

Precision lead-screw transmission system enabling accurate positioning and reliable sealing of the quartz tube, reducing the risk of damage due to manual operation

Dual filtration columns filled with activated carbon and color-changing silica gel for effective carrier gas purification and drying

Branded computer with dedicated control software for automatic test process control

Software-based temperature regulation and stabilization with real-time curve recording, automatic data display, storage, and report generation

Accessories

(1) Heat-resistant quartz tube

(2) Ceramic combustion boat

(3) PTFE-coated gas sampling bag (80 L)

(4) Activated carbon filter column

(5) Color-changing silica gel filter column

(6) K-type thermocouple

(7) Dedicated control software and industrial computer

Test Procedures

1. Pre-Test Preparation

Ensure the tester is installed in a well-ventilated laboratory environment. Verify that the tube furnace, quartz tube, and filtration system are clean and properly assembled. Check that the absorption solution (0.1 N NaOH) and titration reagents are prepared according to specified concentrations. Confirm normal operation of the temperature control system, gas analysis instruments, and data acquisition software.

2. Specimen Loading

Place the prepared test specimen into the ceramic combustion boat. Using the magnetic drive and transmission mechanism, steadily convey the boat into the center of the tube furnace. The lead-screw positioning system ensures accurate alignment and reliable sealing at the quartz tube interface, minimizing gas leakage during the test.

3. Heating and Smoke Generation

Set the target temperature according to the selected standard. The furnace temperature is automatically controlled by the software, with uniform heating achieved through regulated power output. As the specimen undergoes thermal decomposition or combustion, the generated smoke is carried by a controlled gas flow toward the sampling and absorption system.

4. Gas Collection and Analysis

The combustion gases are either introduced into the NaOH absorption solution via bubbling or collected in PTFE-coated gas sampling bags for subsequent analysis. Online infrared gas analyzers continuously measure CO and CO₂ concentrations, while SO₂ and NOₓ are determined using dedicated measurement channels or chemical analysis methods. All test data are automatically recorded and stored by the control software.

Maintenance Information

Regularly inspect the quartz tube, ceramic combustion boat, and furnace interior for residue buildup and clean them as required. Check the condition of the activated carbon and silica gel in the filter columns and replace them when saturation or discoloration is observed. Verify calibration of gas analyzers and temperature sensors according to laboratory quality procedures. Ensure the lead-screw transmission and magnetic drive mechanisms operate smoothly to maintain positioning accuracy.

Conclusion

The GB/T 19666 Toxicity Index Tester provides a comprehensive and standardized solution for evaluating the toxicity of fire effluents from cables and related materials. By integrating precise temperature control, stable smoke generation, flexible gas collection methods, and automated data processing, the system meets the requirements of GB/T, EN, BS, and ISO standards, supporting reliable fire safety assessment in railway and cable industries.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Contact heating and cooling tester
Contact heating and cooling tester Test standard JIS L 1927Textiles-Measurement method of cool touch feeling property GB/T 35263-2017Textiles-Testing and evaluation for cool sensat...
Medical injection needle rigidity tester
Medical injection needle rigidity tester The Medical Injection Needle Rigidity Tester is designed to evaluate the mechanical rigidity of medical injection needles. It measures deflection a...
Universal Material Tensile Testing Machine丨Universal Material Tensile Tester
Universal Material Tensile Testing Machine丨Universal Material Tensile Tester universal testing machineis a high-precision, multi-purpose material testing machine that tests the mechanical properties of various metal material...
Automotive Interior Materials Tactile Perception Quality Testing Procedure System
Automotive Interior Materials Tactile Perception Quality Testing Procedure System Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Automotive seat surfaces: leather, fabric, synthetic leather, and composit...
Stapler Blade Sharpness Tester
Stapler Blade Sharpness Tester It features a 7-inch K600+ core/dot-matrix 65-color 800*480 resolution touchscreen display with English and Chinese menu options. Test parameters, ...
All supplier products

Same products

SUGA SX75 super xenon weather meter supplier
SUGA SX75 super xenon weather meter supplier Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA SX75 7.5kW Super Xenon...
UV & Carbon Arc Light Exposure Tester
UV & Carbon Arc Light Exposure Tester Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chambe...
Acid corrosion resistance cabinet for toilets
Acid corrosion resistance cabinet for toilets Seller: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric ac...