Multi-Function Thermal Conductivity Measurement Platform
Multi-Function Thermal Conductivity Measurement Platform is an absolute-method measurement system designed for accurate determination of thermal conductivity, thermal diffusivity, specific heat capacity, and thermal effusivity of solids, liquids, pastes, and powders. By integrating multiple transient techniques on a single platform, the system enables direct calculation of thermal properties from raw data without calibration materials, supporting reliable and repeatable measurements across a wide range of material types.
Application
The Multi-Function Thermal Conductivity Measurement Platform is suitable for thermal property evaluation in research, quality control, and material development, including:
Polymers, composites, and building materials
Liquids and phase-change materials
Pastes, powders, and bulk solids
Soil and polymeric materials
Typical test samples include solid blocks and plates, liquid samples, powders, pastes, and soil specimens, depending on the selected sensor and test method.
Standards
The platform supports internationally recognized absolute measurement standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
Parameters
| Method | TPS | THW | MTPS | TLS |
|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Soil, pastes, polymers |
| Measurement Module | 3D bulk, anisotropic, plate, thin film; general: specific heat | Bulk | 3D bulk, anisotropic, plate; 1D standard | Bulk |
| Thermal Conductivity (W/m·K) | 0.01–500 | 0.01–2 | 0.03–500 | 0.1–8 |
| Thermal Diffusivity (mm²/s) | 0.01–300 | Up to 0.5 | 0.01–300 | Not applicable |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Not applicable |
| Thermal Effusivity (W·s½/m²·K) | 20–40000 | Not applicable | 20–40000 | Not applicable |
| Sample Size (mm | mL) | Ø10 or square | 20 mL | Ø25 or square |
| Sample Thickness (mm) | ≥0.05 | Not applicable | ≥0.1 | Probe length 100 |
| Maximum Sample Size | Unlimited | Unlimited | Unlimited | Unlimited |
| Test Time (s) | 2–160 | 1 | 2–160 | 180 |
| Accuracy (Thermal Conductivity) | 5% | 2% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 2% | 1% | 2% | 2% |
| Temperature Range (°C) | 0–300 / −75–300 | −50–200 | 0–100 / −50–200 | −40–100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Insert type |
| Supported Standards | ISO 22007-2. ISO 22007-7. GB/T 32064. ASTM E3088 | ASTM D7896 | ISO 22007-7 | ASTM D5334. ASTM D5930 |
Features
Absolute measurement methods with no calibration materials required
Multiple transient techniques integrated on a single platform
Direct measurement of thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil
Raw data–based calculation improves traceability and measurement reliability
Send product request
Other supplier products
| Solid Combustion Rate Tester | This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 33.2.1.4 Test N.1: Test Method for ... | |
| Bag lifting fatigue testing machine | This machine is suitable for up and down vibration fatigue test of plastic handbag, garbage vest bag, kraft paper bag, woven bag and other bags bea... | |
| Rapid screening Calorimeter | The rapid - screening calorimeter is a professional calorimetric instrument for the quick assessment of reaction thermal hazards. It supports multi... | |
| Metal Corrosivity Tester | standards GB/T 15970 ISO 7539 ASTM G31 GB/T 10125 Scope of Application The metal corrosivity tester is designed and manufactured in line with... | |
| Mattress rollator tester | The Mattress Rollator is a laboratory durability testing system designed to evaluate the long-term structural stability, height retention, and hard... |
Same products
| Common Rail Control Valve Assembly F00ZC01307 | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ... | |
| Fuel Injector Control Valve Set F00RJ01479 | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto... | |
| Fuel Injector Valve Set F00RJ02213 | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto... | |
| Common Rail Injector Valve Set F00RJ00339 | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ... | |
| Fuel Injection Pump 723945- 51320 for Yanmar Wb93r Wb97r Wb97s Wb98a | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti... |