Catheter Leakage and Compliance Tester
Applications
The catheter leakage and compliance tester is mainly used to detect the leakage and compliance of medical catheters (such as the breathing circuits of ventilators and anesthesia machines). Specifically, it can: Leakage Test: By applying a certain pressure inside the catheter and monitoring the rate or extent of pressure drop, it determines whether there is leakage in the catheter. This is crucial for ensuring the sealing and safety of the catheter during medical procedures. Compliance Test: Compliance refers to the ability of the catheter to deform when subjected to external forces. The tester applies a certain pressure inside the catheter and measures the volume change of the catheter to evaluate its compliance. This is of great significance for understanding the flexibility and elasticity of the catheter, as well as its applicability in medical applications.
Standards
ISO 13988-1:2017: Intravascular catheters - Part 1
ISO 8536-4:2016: Medical infusion equipment
YY/T 0285.4-2017: Intravascular catheters - Part 4
YY/T 1551.1-2017: Non-intravascular catheters
Features
Color LCD large screen display: Real-time display of test data and statistical values, intuitive and clear.
Intelligent touch control operation: Simple human-machine interface for quick experiment switching.
High-precision electronic flow meter: Achieves precise flow control, avoiding testing errors.
Top-tier sensor system: High-sensitivity data acquisition ensures stable and consistent test results.
Data security management: Four-level access control and encrypted storage prevent unauthorized operations and ensure the integrity and traceability of results.
Convenient result output: Equipped with a micro printer, supporting instant printing of single test results and statistical data.
Technical Parameters
| Parameter | Specification |
|---|---|
| Pressure Range | Determined by test object & application scenarios:- e.g., 0 - 300kPa for medical breathing circuits- Narrower range (e.g., 0 - 50kPa) for routine compliance testing |
| Pressure Accuracy | Key for test accuracy; generally requires ±0.1% or higher (e.g., 0 - 50kPa pressure sensor can reach one-thousandth accuracy) |
| Flow Range | Covers various flow situations of tested catheters; common flowmeter range: 0 - 100L/min |
| Flow Accuracy | Important indicator; generally requires ±1% or higher (e.g., ±1%FS for 2L/min mass flow controller) |
| Volume Measurement Range and Accuracy | - Range: From a few milliliters to several liters (adapts to different catheter volumes)- Accuracy: Generally needs to reach ±0.1ml or higher (to accurately calculate catheter compliance) |
| Test Time Range | - Leakage tests: Flexible setting (a few seconds to several hours)- Compliance tests: Controls pressure change rate & time interval to capture catheter volume changes at different pressure stages |
Accessoriess
Standard accessories include: specialized connectors for different sizes of medical tubing (such as ventilator/anesthesia machine breathing circuits), pressure/flow test tubing, tubing fixing clamps (to ensure sample stability during testing), standard test samples for equipment calibration (including standard leakage and compliance components), operating manual, and calibration certificate.
Send product request
Other supplier products
| Safety Helmets Against Molten Metal Splashing Tester | Standard GB/T 2812-XXXX: Safety Helmets – Test Methods for Molten Metal Resistance (Draft Standard) GB 2811-2019: Head Protection – G... | |
| Syringe piston thrust tester | Product introduction The syringe piston thrust tester is a kind of high precision and high stability measuring equipment, which is used to measure... | |
| Battery short-circuit tester丨Battery short-circuit chamber | Product introduction The device is designed based on a variety of battery short-circuit test standards. According to the standard requirements, t... | |
| Safety shoe impact tester | According to the criteria Bs-953.1870 EN-344. ANSI-Z41 CSA-Z195 ISO K88782 EN ISO 20344. ANSI-Z41 BS EN-344 CSA-ZI95 LD50-1994 AS/NZS 22... | |
| Cylindrical Battery In-Situ Volume Swelling Testing System | The Cylindrical Battery In-Situ Volume Swelling Testing System is designed for real-time measurement and analysis of volume and dimensional changes... |
Same products
| Fuel Injection Pump 723945- 51320 for Yanmar Wb93r Wb97r Wb97s Wb98a | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti... | |
| VE Injection Pump VE3/9F1500L376AG | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The VE Injection... | |
| Automotive seat durability and strength testing machine | Seller: Standard International Group (HK) Limited | The Automotive Seat Three-Station Headrest and Backrest Static Strength Testing Machine is design... | |
| Racing Seatback Headrest Restraint Device, Front and Rear Impact Testing Machine | Seller: Standard International Group (HK) Limited | The Racing Seat Headrest Restraint and Front-Rear Impact Testing Machine is designed to evaluate ... | |
| Laboratory car wash simulator for automotive testing | Seller: Standard International Group (HK) Limited | The Laboratory Car Wash Simulator is a specialized testing system designed to replicate automatic... |