16-Segment Heated Thermal Manikin (Dry Type)

Application

The 16-Segment Heated Thermal Manikin is used in the following application areas:

(1) Cleanroom airflow evaluation and contamination risk assessment

(2) HVAC research, teaching, and indoor thermal comfort studies

(3) Thermal insulation testing of workwear, protective clothing, and medical garments

(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines

(5) Aircraft, spacecraft, and cabin thermal environment studies

(6) Hospital operating room temperature control and patient thermal protection testing

(7) Occupational safety and thermal stress evaluation in controlled environments

Standards

The system is designed and manufactured with reference to the following international and national standards:

(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments

(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities

(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)

(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin

(5) EN 14058 – Protective clothing against cool environments (reference testing)

(6) GB/T 18883-2020 – Indoor air quality standard

(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals

(8) GB 50333-2013 – Technical code for hospital HVAC system design

(9) GB/T 4249-2019 – Indoor thermal environment impact on human body

(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing

Parameters

ComponentTechnical Parameter
Manikin body 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape
Heating system Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C
Zone uniformity Maximum temperature difference between zones ≤ 1.0°C
Control system 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning
Control box 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors
Heat output 70–100 W per manikin, adjustable
Surface material Smooth, non-particle shedding, suitable for cleanroom use
Operating environment Temperature 10–40°C; humidity 15–95% RH
Power supply AC 220–240 V, 50 Hz
Power consumption Peak ≤ 1200 W; steady-state heat flux 0–300 W/m²
Manikin height Approx. 180 cm (standing posture)
Manikin weight Approx. 45 kg
Optional customization Child or infant manikins; individual body parts; lying posture patient simulation

Features

(1) Sixteen independent heating zones for stable and uniform heat distribution

(2) Dry-type design without sweating or breathing for simplified operation and cost efficiency

(3) High-precision temperature control using dedicated PID regulation

(4) Adjustable surface and core temperature for various thermal simulation scenarios

(5) Flexible posture options including standing, sitting, or lying configurations

(6) Cleanroom-compatible surface with low particle emission

(7) Quick-connect cabling and mobile control unit for convenient installation

(8) Compatibility with expanded GB/T and YY/T standards for medical and HVAC testing


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement
Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement The Autocatalytic Decomposition Temperature Tester with Thermal Insulation (Adiabatic SADT Tester) is a critical instrument for evaluating the ther...
Spring Testers and Testing Machines
Spring Testers and Testing Machines The Spring Tension and Compression Testing Machine is designed to accurately evaluate the tensile and compressive deformation, as well as the load ...
Coatings Shear Fatigue Test device
Coatings Shear Fatigue Test device Standard YY/T 0988.13-2017 (China): Specifies shear fatigue testing protocols for coatings on metallic substrates, including load ratios, frequenc...
Tracking Index Tester,ASTM D2344arc current tracking analyzer
Tracking Index Tester,ASTM D2344arc current tracking analyzer Leakage Current Tracking Tester is designed to evaluate the tracking resistance of solid electrical insulating materials under humid conditions. By...
Underwear Pressure Comfort tester
Underwear Pressure Comfort tester Application You use this tester to assess wearing pressure and contact force of garments under simulated human body conditions. It is suitable fo...
All supplier products

Same products

Common Rail Control Valve Assembly F00ZC01307
Common Rail Control Valve Assembly F00ZC01307 Seller: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injector Control Valve Set F00RJ01479
Fuel Injector Control Valve Set F00RJ01479 Seller: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Fuel Injector Valve Set F00RJ02213
Fuel Injector Valve Set F00RJ02213 Seller: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecto...
Common Rail Injector Valve Set F00RJ00339
Common Rail Injector Valve Set F00RJ00339 Seller: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ...
Fuel Injection Pump 723945- 51320 for Yanmar Wb93r Wb97r Wb97s Wb98a
Fuel Injection Pump 723945- 51320 for Yanmar Wb93r Wb97r Wb97s Wb98a Seller: Pioneer Diesel Parts Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti...