Walk-in Humidity Test Chamber High and Low Temperature Aging Room
Applications
Walk-in High-Temperature Aging Chambers are typically assembled on-site using insulated panels (double-sided color steel sheets with insulation material in between). Chamber dimensions are customized to client specifications. The complete walk-in high/low temperature and humidity test chamber features comprehensive safety protection devices and provides troubleshooting methods, with safety ratings surpassing other brands. Protection Devices: Fuse-less switches, fuses, over-temperature protection, dry-run protection, low-water protection, liquid level protection, compressor overpressure, overheat, and overcurrent protection. Comprehensive protection includes compressor overload/overheat protection, phase loss protection, and a fault alarm system.
Standards
GJB150.3 (ML-STD-810D) High Temperature Test Method
GJB150.4 (MIL-STD-810D) Low Temperature Test Method
GJB360.8-87 (MIL-STD-202f) High Temperature Life Test
GB/T5170.2-96 Temperature Test Equipment
GB2423.1-89 (IEC68-2-1) Basic Environmental Test Procedures for Electrical and Electronic Products Test A: Low Temperature Test Method
GB2423.2-89 (IEC68-2-2) Basic Environmental Test Procedures for Electrical and Electronic Products - Test B: High Temperature Test Method
GB5170. 2. 3. 5. 6-95 “Calibration Methods for Basic Parameters of Environmental Test Equipment for Electrical and Electronic Products - Low Temperature, High Temperature, Constant Humidity and Heat, Alternating Humidity and Heat Test Equipment” Requirements
Features
1. Simple maintenance and user-friendly operation are key advantages of our products.
2. The independent frame design ensures the refrigeration system and air distribution system operate separately.
3. Maintenance and repairs can be performed during unit operation, resulting in low annual failure rates and simplified, rapid servicing.
Parameters
| Item | Specifications |
|---|---|
| Dimensions | 200 cm (W) × 200 cm (H) × 200 cm (D); customizable per customer requirements, with external dimensions subject to actual size |
| Temperature Range | Optional ranges: 0°C~20°C / -40°C~60°C / -70°C~+85°C / 100°C (lower temperature ranges are higher in cost; choose based on product needs) |
| Temperature Fluctuation | ±0.5°C (defined as half the difference between the highest and lowest measured temperatures at the center point) |
| Temperature Uniformity | ±2.0°C (defined as the arithmetic mean of the differences between highest and lowest measured temperatures per test) |
| Heating Time | From room temperature (+10°C) to +85°C: <60 minutes, non-linear no-load heating rate ≈3°C/min |
| Cooling Time | - From +10°C to 0°C: <30 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -20°C: <45 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -40°C: <60 minutes, non-linear no-load cooling rate ≈1°C/min |
| Operating Noise | A-weighted sound level ≤60 dB(A), measured in anechoic chamber at 25°C ambient temperature, using A-weighting, averaged over 8 test points (each at 1m from noise source and 1m above ground) |
Accessories
Temperature and humidity sensors
LED display control panel with PID auto-tuning
Stainless steel air circulation ducts and heating elements
Safety devices: fuses, overload protection, leakage detection
Adjustable shelving for test samples
Send product request
Other supplier products
| industrial grade clothing steamer | Applications Industrial Dry Cleaning Machines: Suitable for cotton, wool, polyester, blends, down, and specialty fabrics. Maintain color, preven... | |
| Qinsun SUNTEST XXL+ | Qinsun SUNTEST XXL+is a large xenon lamp weathering and photoaging tester that complies with various ISO, ASTM, and ICH industry standards. The exp... | |
| Laminoplasty Plate System Fatigue Testing Machine | Standard ASTM F2193-18: Specifies static/fatigue testing protocols for spinal constructs, including lamina fixation plates. ISO 12189-1: Defines ... | |
| Safety Helmets Acceleration Impact & Penetration Tester | The Safety Helmets Acceleration Impact & Penetration Tester is a dual-mode testing instrument designed to evaluate helmet performance under bot... | |
| Direcct flame impingement Tester | Introduction The testerisdesignedaccording to the BS476-12:1991.Method of test for ignitability of products by direct flame impingement.The accura... |
Same products
| Common Rail Injector Valve Set F00RJ00339 | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Common Rail ... | |
| Fuel Injection Pump 723945- 51320 for Yanmar Wb93r Wb97r Wb97s Wb98a | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The Fuel Injecti... | |
| VE Injection Pump VE3/9F1500L376AG | Seller: Pioneer Diesel Parts | Pioneer Diesel Parts Whats/App: +86 152 6025 8100 Web: pioneerdieselparts.com The VE Injection... | |
| Automotive seat durability and strength testing machine | Seller: Standard International Group (HK) Limited | The Automotive Seat Three-Station Headrest and Backrest Static Strength Testing Machine is design... | |
| Racing Seatback Headrest Restraint Device, Front and Rear Impact Testing Machine | Seller: Standard International Group (HK) Limited | The Racing Seat Headrest Restraint and Front-Rear Impact Testing Machine is designed to evaluate ... |