Export Medical needle toughness tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
(1) Medical disposable injection needles – evaluating bending durability before packaging.
(2) Insulin pen needles – testing ultra-thin walls for high flexibility without fracture.
(3) Vacutainer blood collection needles – ensuring mechanical reliability during insertion.
(4) IV infusion needles and cannulas – verifying structural integrity under repeated bending stress.
(5) Specialty surgical needles – quality assurance for orthopedic or microsurgical applications.
Standards
The device meets and supports testing according to the following international and national standards:
(1) GB15811 – Sterile disposable injection needle
(2) GB18457 – Stainless steel needle for medical equipment manufacturing
(3) ISO 9626 – Stainless steel needle for medical use
Test Procedure
(1) Fix one end of the needle tube firmly in the jig.
(2) Adjust the span according to needle wall type:
Normal wall: 25° bending
Thin wall: 20° bending
Ultra-thin wall: 15° bending
(3) Apply force at the specified span position, bi-directionally, 20 times at a frequency of 0.5 Hz.
(4) Observe the needle for breakage, deformation, or failure.
Principle: One end of the needle is fixed. A force is applied from the fixed point to the prescribed span, bending in one direction and then in the opposite direction, repeated for the defined number of cycles.
Technical Parameters
| Parameter | Specification |
|---|---|
| Syringe nominal specifications | 0.2 – 3.4 mm |
| Test frequency | 0.5 Hz |
| Rocker arm bending angle | 15°, 20°, 25° (switch selectable, displayed on high-brightness 4-digit LED) |
| Bending distance | 6 – 95 mm, accuracy ±0.1 mm (10 selectable spans) |
| Number of experiments | Bi-directional force 20 times |
| Net weight | 10 kg |
| Overall dimensions (L × W × H) | 300 × 240 × 240 mm |
| Standards | GB15811. GB18457. ISO 9626 |
| Control & Display | 5.7-inch LCD touch menu (120 × 90 mm) |
| Upgrade | Free perpetual upgrade according to national standards |
| Power supply | AC 220 V, 50 Hz |
| Part List | Host (1 set), Printing paper (1 roll), Fixture (1 set), Weight (1 set), Operating Instructions |
Accessories
(1) Printing paper (1 roll)
(2) Needle fixture (1 set)
(3) Weight set for bending calibration
(4) Operating instructions in English/Chinese
Maintenance Information
(1) Keep the device clean and dry; wipe with a soft cloth after use.
(2) Check the calibration of bending angles and LED display periodically.
(3) Avoid impact or vibration to ensure precise mechanical performance.
(4) Follow local electrical safety standards for power supply and grounding.
Send product request
Other supplier products
| Konan Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to the UN Recommendations on the Transport of Dangerous Goods... | |
| Car seat static strength tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Car Seat Static Strength Tester is a dedicated testing system used to evaluate the stat... | |
| Medical injection needle puncture force test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com The needle puncture force simulates the skin tester with a 5.7-inch (120 x 90) single color... | |
| Micro Rapid Closed Cup Flash Point Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Reference Standards: SH/T 0768. SN/T 3077.1. DL/T 1354. ASTM D6450 SN/T 3077.2. ASTM D7094... | |
| Dry and Wet Retroreflectometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards EN ISO 20471:2013 ANSI/ISEA 107-2015 GB 20653-2006 GB/T 18833 Main uses Dry... |