.

AI-powered glass bottle internal pressure resistance tester equipment

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The internal pressure resistance tester for glass bottles is mainly used to evaluate the ability of glass bottles to withstand pressure under different pressure conditions. Through testing, we can determine whether glass bottles can withstand a certain internal pressure without breaking or deforming during the processes of filling, transportation, and use. This device is widely applied in industries such as beer brewing, pharmaceutical production, and food packaging, and is of great significance for ensuring product quality and consumer safety. In the beer - brewing field, the internal pressure resistance tester for glass bottles is used to inspect the internal pressure - resistance ability of beer bottles and other alcohol - beverage packaging bottles, ensuring that they will not break due to pressure changes during filling, transportation, and use. In the pharmaceutical production process, this device is used to test the internal pressure resistance of pharmaceutical packaging bottles such as antibiotic vials and infusion bottles, safeguarding the stability and safety of drugs during storage and transportation. In addition, in the food - packaging field, various beverage bottles such as carbonated beverage bottles and juice bottles also need to undergo internal pressure - resistance testing using this device.

Standards

The design and manufacture of the internal pressure resistance tester for glass bottles comply with a series of national and international standards to ensure the accuracy and reliability of test results. Among the more common standards are GB/T 4546 - 2008 Test Method for Internal Pressure Resistance of Glass Containers and ISO 7458:2004 Test Method for Internal Pressure Resistance of Glass Containers. These standards specify in detail the test methods for the internal pressure resistance of glass bottles, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.

Technical Parameters

Technical ParameterSpecification
Testing Pressure Range Usually it can reach 0 - 6MPa or higher (specific range depends on equipment model and testing requirements); covers internal pressure-resistance testing needs of most glass bottles.
Display Accuracy Generally 0.001MPa or higher; enables precise display of pressure changes during the testing process.
Pressurizing Medium Usually water (ensures no additional pressure impact on glass bottles; also convenient for controlling and monitoring pressure changes).
Testing Speed Relatively fast; testing time per bottle ranges from a few seconds to a dozen seconds (depends on equipment model, testing pressure, and specimen specifications); helps improve testing efficiency and productivity.
Overall Error Usually less than 0.5%FS (full-scale error); ensures the accuracy and reliability of test results.
Working Environment Needs to be used in a certain environment: temperature range of 5 - 40℃ (varies by equipment model), relative humidity not exceeding a certain value; helps maintain equipment stability and extend its service life.
Safety Performance Equipped with safety features (e.g., leak-protection control circuits) to ensure operator safety; also has automatic fault detection and common fault prompting functions, facilitating prompt problem identification and resolution.

Accessoriess

Standard configuration: Glass bottle internal pressure testing machine main unit, micro printer, fixtures

Optional accessories: Testing software, communication cable


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Battery Powder resistivity meter
Battery Powder resistivity meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YS/T 587.6-2006 GB/T 24525-2009 GBT 30835-2014 Product Advantages Unmatched ...
Bending deformation suture needle instrument
Bending deformation suture needle instrument Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY/T 0043 :Medical Suture Needles YY/T 0166 :Surgical Suture Needles with Threa...
Diesel Water Ash Sulfur Test Equipment
Diesel Water Ash Sulfur Test Equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. In diesel quality control, homogenization of samples provides representati...
Fully Automatic High-Temperature Specific Heat Capacity Tester,fully automatic thermal analysis equipment for metals and composites
Fully Automatic High-Temperature Specific Heat Capacity Tester,fully automatic thermal analysis equipment for metals and composites Whats/App: +86 156 1874 6768 Web: standard-groups.com Fully Automatic High-Temperature Specific Heat Capacity Tester is a state-of-the-art instru...
Suitcases Vibration Impact Tester
Suitcases Vibration Impact Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is used to test the shock resistance of various luggage handles, car stitches ...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...