Automated transient hot-wire thermal conductivity testing equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The Transient Hot-Wire Liquid Thermal Conductivity Analyzer is widely used in research, development, and quality control environments where accurate thermal property data of fluids and semi-fluids is required. Typical application scenarios include:
Engine coolants, lubricants, and heat transfer fluids
Phase change materials (PCM) for thermal energy storage
Chemical liquids and pastes used in process engineering
High-viscosity fluids and suspensions
Research on thermal transport mechanisms
Typical tested products include engine coolants, PCM slurries, silicone oils, polymer solutions, and specialty chemical fluids.
Standards
The analyzer is designed and tested in accordance with internationally recognized standards:
(1) ASTM D7896-19 — Standard Test Method for Thermal Conductivity, Thermal Diffusivity, and Volumetric Heat Capacity of Liquids Using the Transient Hot-Wire Method
Parameters
| Parameter | Configuration 1 | Configuration 2 | Configuration 3 |
|---|---|---|---|
| Material | Liquids & phase change materials | Liquids & phase change materials | Liquids & phase change materials |
| Thermal Conductivity (W/m·K) | 0.01 – 2 | 0.01 – 2 | 0.01 – 2 |
| Additional Properties | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat |
| Viscosity Range (cP) | 0.001 – 10.000.000 | 0.001 – 10.000.000 | 0.001 – 10.000.000 |
| Sample Volume (mL) | 20 | 20 | 20 |
| Test Time (s) | 1 | 1 | 1 |
| Accuracy (Thermal Conductivity)* | ±2% | ±2% | ±2% |
| Repeatability (Thermal Conductivity)* | ±1% | ±1% | ±1% |
| Temperature Range (°C) | 10 to 200 | -40 to 200 | -160 / -40 / 0 to 300 |
| Pressure (bar) | Up to 20 | Up to 20 | Up to 35 |
| External Cooling Required | No | Yes | Yes |
| Standard | ASTM D7896-19 | ASTM D7896-19 | ASTM D7896-19 |
Accessories
(1) Paste and PCM element — Designed for easy loading of phase change materials; spring-loaded structure accommodates thermal expansion and contraction while maintaining contact with the THW wire
(2) Observation element — Glass viewing port for monitoring sample conditions such as phase separation, boiling, or particle sedimentation
(3) Ambient density powder element — Suitable for basic powder testing at ambient pressure
(4) Variable density powder element — Spiral compression system allows density adjustment and stable wire contact
(5) Vertical element holder — Enables vertical loading for paste, PCM, and powder elements
(6) Cooling system options —
Economic circulator: down to 0 °C
Circulator: down to -15 / -35 / -50 °C
Advanced options: down to -100 / -150 °C
Test Procedures
Sample Preparation
Pour approximately 20 mL of liquid into the selected sample element. The short test duration effectively suppresses convection, allowing accurate measurement across a wide viscosity range. Back pressure up to 35 bar can be applied for measurements above the boiling point.
Approximate time: 1 minute
Sensor Insertion
Insert the THW sensor into the sample element and place it into the integrated temperature platform for controlled testing.
Approximate time: 1 minute
Measurement Execution
The software automatically controls isothermal steps from -150 °C to 300 °C, depending on configuration.
Approximate time: < 1 minute
Result Output
The Windows-based software verifies measurement validity, suggests adjustments if required, and generates reports. Results can be saved, exported to Excel, or sent via .
Approximate time: 1 minute
Maintenance Information
Keep the THW sensor clean and free of residue after each test
Inspect sensor integrity regularly to ensure stable resistance behavior
Verify temperature control performance periodically
Store sample elements in a clean, dry environment
Follow standard laboratory practices for handling liquids and phase change materials
Send product request
Other supplier products
| Filter Media Tester G508 supplier for HVAC and industrial filters | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You can use the G508 test bench for the following applications and test object... | |
| Vertical Flammability Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com VTEC Vertical Flammability Chamber Testing Standards: ASTM D6413-99. DOC-FF 3/71. CALIF TB... | |
| Safety Helmets Wearing Stability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB 811-2022: Safety Helmets – General Technical Requirements GB 24429-2009... | |
| Air chamber breakdown voltage tester for components | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Mainly suitable for solid insulating materials such as wire bushings, resins a... | |
| Automotive Oil Filter Performance Test Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 2941:2009:Hydraulic fluid power — Filter elements — Verification... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |