Custom garment shielding performance testing system

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The testing system supports compliance with the following standards:

GB 23463-2025 – Protective Clothing for Microwave Radiation

GB/T 33615-2017 – Methods for Testing Electromagnetic Shielding Performance of Garments

DIN 32780-100 – Protective Clothing, Part 100: Electromagnetic Field Protection in 80 MHz–1 GHz Range

IEC 61000-4-3 – Testing and Measurement Techniques for Radiated RF Electromagnetic Fields

ISO 105-X12 – Textiles: Color Fastness to Electromagnetic Effects (Reference for material durability)

Parameters

ParameterSpecification
Test Object Protective garments, including finished products and key raw materials
Test Environment Semi-anechoic chamber with low electromagnetic interference
Frequency Range 80 MHz – 1 GHz (standard)
Measurement Points Head, chest, abdomen of manikin
Sensors Embedded EMF receiving sensors in manikin
Radiation Source Signal amplifier with directional transmitting antenna
Shielding Effectiveness Measurement Vector Network Analyzer (VNA)
Environmental Conditions Controlled temperature and humidity to minimize measurement variability
Data Output Real-time attenuation curves and shielding performance reports
Power Supply AC 220V, 50/60 Hz
Footprint Chamber and system optimized for laboratory installation

Features

Realistic simulation of human exposure using test manikin

Semi-anechoic chamber minimizes external electromagnetic interference

High-precision vector network analyzer measures shielding effectiveness accurately

Multi-point measurement captures shielding at head, chest, and abdomen

Supports evaluation of raw materials, components, and finished garments

Integrated software for data acquisition, analysis, and automatic report generation

Capable of long-term performance evaluation including wash and abrasion tests

Test Procedures

Sample Preparation

Include finished garments and critical raw materials to evaluate both overall and component-level shielding.

Ensure garments are properly mounted on the manikin with sensors correctly positioned.

Environmental Control

Conduct testing in a low-noise, semi-anechoic chamber to minimize external electromagnetic interference.

Measurement

Activate the electromagnetic radiation source and record real-time attenuation at head, chest, and abdomen using the manikin sensors.

Use the Vector Network Analyzer to measure shielding effectiveness across the target frequency range.

Durability Assessment

Optionally perform wash, friction, and other stress tests on the garment before re-evaluating shielding performance.

Data Recording

Analyze and record results with integrated software, generating performance curves and standardized reports.

Maintenance Information

Regularly inspect and calibrate the vector network analyzer and sensors to ensure accuracy

Maintain semi-anechoic chamber cleanliness and check shielding integrity periodically

Verify signal amplifier and antenna operation before each test

Ensure environmental sensors are functional and provide accurate temperature and humidity readings

Store manikin and sensitive components properly when not in use to prevent mechanical or electrical damage


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Precision Metal Wire Wrap Tester ASTM International
Precision Metal Wire Wrap Tester ASTM International Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 2976 – Wire Winding Test Method for Metal Materials...
Cabin air filter PM and VOC removal efficiency test system
Cabin air filter PM and VOC removal efficiency test system Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Test System for both particle separation and gas absorption/desorption of of ...
Photovoltaic module insulation resistance tester
Photovoltaic module insulation resistance tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Photovoltaic Module Insulation Resistance Tester is a precision instrument designed for...
Appliance Stability Tester
Appliance Stability Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Appliance Stability Tester is designed to evaluate the mechanical stability and anti-ti...
Testing apparatus-Back & Butt Forms
Testing apparatus-Back & Butt Forms Whats/App: +86 156 1874 6768 Web: standard-groups.com 5th Percentile Female SAE Butt Form The 5th Percentile Female SAE Butt Form is meticulousl...
All supplier products

Same products

PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...
PanPHE gasketed plate heat exchangers
PanPHE gasketed plate heat exchangers Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ...