ASTM E84 / ISO 5660 Surface Flame Spread Test Apparatus
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The apparatus supports compliance with the following international standards:
GB/T 8624‑2012 – Classification of combustion performance of building materials
GB/T 27904‑2011 – Flame spread performance test methods for interior decoration materials
GB/T 2406.2‑2009 – Plastics burning performance test, vertical burning method
GB/T 2408‑2008 – Plastics burning performance test, horizontal burning method
ISO 5658‑1 – Fire spread index of building materials, small flame spread test, Part 1
ISO 5658‑2 – Fire spread index of building materials, small flame spread test, Part 2
ISO 5660‑2 – Heat release rate, smoke production, and mass loss, Part 2: Flame spread test method
ISO 5660‑4 – Heat release rate, smoke production, and mass loss, Part 4: Automotive interior materials
ASTM E162 – Surface flammability characteristics of materials (Flame Spread Index, FSI)
ASTM E648 – Assessment of carpet material flame spread
UL 94 – Plastic material flammability testing (Vertical and Horizontal Burning)
BS 476‑6:1989 + A1:2009 – Fire tests on building materials, Part 6: Small flame spread test
BS 6853:1999 – Railway vehicle material flame spread, smoke density, and toxicity evaluation
Parameters
| Parameter Category | Details |
|---|---|
| Dimensions | 1760 × 1450 × 2130 mm |
| Weight | 678 kg |
| Radiation Panel | 850 × 850 mm |
| Power Supply | 220V, 50Hz, 10A |
| Operating Temp | 10°C – 35°C |
| Gas Requirements | Industrial propane, compressed air |
Features
Large Radiation Panel: 850 × 850 mm with reinforced structural support.
Vertical Sample Holder: Includes standard scale markings to measure flame spread distance and critical heat flux.
Water-Cooled System: Prevents sample holder damage during long-duration high-temperature testing.
Small Flame Ignition: Uses electric spark ignition for consistent flame application.
Automatic Safety Cut-Off: High-temperature sensors shut off gas supply if the radiation panel extinguishes.
Calibrated Heat Flux Sensors: Traceable to NIST for accurate radiation flux measurement.
Digital Control Box: Allows adjustment of gas and air flow with digital display of radiation flux.
PLC & HMI Integration: Displays all test parameters for real-time monitoring and control.
Accessories
Water-cooled sample holder
Calibrated porous panel
Heat flux sensors
Electric spark ignition system
PLC & HMI control system
Gas and air flow regulation valves
Safety interlock devices
Test Procedures
Ensure a minimum of 5 meters of clear space around the installation area.
Connect the apparatus to 220V, 50Hz, 10A power supply.
Supply industrial propane and compressed air to the system.
Mount the test sample vertically on the water-cooled holder.
Adjust the radiation panel and calibrate heat flux sensors.
Ignite the sample using the small flame ignition system.
Monitor flame spread distance and propagation speed using the scale markings and digital sensors.
Record data for critical heat flux and flame spread classification.
After testing, shut off gas and air supply and allow the apparatus to cool before sample removal.
Maintenance Information
Regularly inspect and clean the radiation panel and water-cooled holder.
Check gas and air supply lines for leaks before each test.
Calibrate heat flux sensors periodically to maintain traceability.
Inspect electrical connections and PLC/HMI for operational stability.
Replace worn or damaged safety interlocks immediately.
Send product request
Other supplier products
| Coating abrasion resistance test device | Product Introduction: The determination of scratch resistance of the coating is very similar to the scratch test of the coating, but this test met... | |
| Thermal Conductivity Tester for Silicone and Ceramic Substrates,ASTM D5470 industrial and lab material thermal tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Thermal Conductivity Tester for Silicone and Ceramic Substrates is a high-precision instrum... | |
| Hip Joint Prostheses Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0651.1-2016 (China): Specifies wear testing parameters for total hip prosthe... | |
| Automotive Sunshade End Cap Assembly Line,Automotive interior sunshade assembly line equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automotive Sunshade End Cap Assembly Line is an automated production system designed fo... | |
| Finger Abrasion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Universal Finger Abrasion Tester can simulate virtually all wear processes in... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |