Smoke Fire Detector Threshold Test Chamber
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system conforms to the following national and international standards:
GB 4715-2005 – Technical Requirements and Test Methods for Point-Type Smoke Fire Detectors (China)
ISO 7240-7 – Fire Detection and Alarm Systems, Part 7: Smoke Detectors Using Scattered, Transmitted Light, or Ionization
EN 54-7 – Fire Detection and Fire Alarm Systems, Smoke Detectors
UL 268 – Standard for Smoke Detectors for Fire Protective Signaling Systems
EN54-7
EN54-29
EN14604
EN54-5
Parameters
| Unit | Specification |
|---|---|
| Temperature Range | 0–55 °C, adjustable via heating rods |
| Variable Frequency Fan | Supply voltage: 220 V; Max. static pressure: 330 Pa; Adjustable air volume: 0–275 m³/h |
| Airflow Requirement | 0.2 m/s |
| Optical Density Meter | Wavelength: 880–950 nm |
| Omega K-Type Sheathed Thermocouple | Diameter: 1.5 mm; Temperature measurement range: 0–1100 °C |
Features
Steel structure chamber with anti-rust spray finish.
Observation glass on the chamber for visual monitoring of smoke distribution.
Independent control box for flexible laboratory layout.
Fan connected with soft couplings to reduce vibration impact on test data.
Equipped with an ion concentration meter to test the response threshold of ionization detectors.
Flash device included to simulate environmental lighting conditions.
Siemens dedicated temperature module for stable and reliable temperature data acquisition.
Imported Omega thermocouple with compensation wiring reduces temperature measurement deviations.
Programmable logic controller (PLC) enables system function control, paired with dedicated data acquisition modules.
Real-time data acquisition ensures stability and reliability.
Electrical components from reputable industry brands, controlled via industrial PC with dedicated software for real-time recording, storage, and visualization of test data.
Accessories
Observation glass
Variable frequency fan assembly
Heating rod modules
Optical density meter
Ion concentration meter
Flash simulation device
Omega K-type thermocouple and compensation wiring
Siemens temperature acquisition module
PLC controller with data acquisition modules
Industrial PC and dedicated software
Test Procedures
Install the smoke fire detector into the test chamber.
Power on the chamber and set the target temperature within 0–55 °C.
Activate the variable frequency fan and adjust airflow to 0.2 m/s.
Initiate the smoke generation process and monitor optical density readings.
Conduct threshold, repeatability, orientation, and airflow tests according to GB 4715-2005 protocols.
Use ion concentration meter to verify ionization detector response, if applicable.
Apply flash simulation to assess detector response under different lighting conditions.
Record all data in real time using the industrial PC and dedicated software for analysis.
Maintenance Information
Inspect heating rods and replace if temperature control is unstable.
Regularly clean or replace optical density meters and ion concentration sensors to maintain accuracy.
Check fan soft coupling connections to prevent vibration-related errors.
Verify thermocouple calibration periodically to reduce measurement deviations.
Ensure PLC, data acquisition modules, and industrial PC function correctly; perform software updates as required.
Clean observation glass to maintain clear visibility during tests.
Send product request
Other supplier products
| Shoe Shank Stiffness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard SATRA TM256: Flexural and torsional stiffness testing for athletic, safety, and c... | |
| High Temperature Walk-In Oven/Curing Chamber | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB 50052: Code for design of power supply and distribution sys... | |
| Bottle base and side wall thickness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The design and manufacture of the wall and bottom thickness tester for bottles c... | |
| Wool Shrinkage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com YM116 type wool fold shrinkage tester is a precision instrument to determine the length of ... | |
| Industrial Oven for Batteries | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Real-time temperature monitoring, temperature range can be customi... |
Same products
| ER4043 Silicon Aluminum Welding Wire | Seller: 868776 | Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin... | |
| HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line | Seller: Shandong HUASU Plastic Technology Co.,Ltd. | The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi... | |
| PanEVAP & MVR system | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... |