The instrument is designed to comply with the following standards:
(1) YY/T 0325-2016: Urinary Catheters – Flow and Bending Performance (China)
(2) GB/T 15812.1-2005: Disposable Catheters – General Requirements (China)
Optional references for broader compliance:
(3) ISO 10555-3: Sterile single-use intravascular catheters – Part 3: Single-use catheters for hemodialysis
(4) ASTM F2392: Standard Test Method for Catheter Performance
Features
(1) Programmable controller with touch screen interface for easy parameter setup.
(2) Real-time monitoring of force and flow data.
(3) Automatic result evaluation with buzzer alarm for unqualified tests.
(4) Integrated printer for immediate documentation of test results.
(5) Adjustable fixtures to accommodate various catheter sizes and types.
(6) Automatic circulation of water pump to simulate physiological conditions.
(7) Dual language interface (Chinese/English) for global usability.
Parameters
| Parameter | Specification |
|---|---|
| Static level height | 1000 ± 5 mm, automatic water pump circulation (adjustable) |
| Time controller | 0 – 60 min, error ±1 s |
| Test fixture | Suitable for various catheters |
| Flow calculation method | Measuring cylinder method |
| Flow rate | > 500 mL/min |
| Overall size (L × W × H) | 400 × 290 × 240 mm |
| Control system | Programmable PLC with touch screen |
| Printing | Onboard printer for real-time test results |
Accessories
(1) Main test unit – 1 set
(2) Fixtures for various catheter types – 1 set
(3) Onboard printer paper – 1 roll
(4) Operation manual – 1 set
(5) USB storage device (optional)
Test Procedures
(1) Install the catheter into the test fixture, ensuring proper alignment.
(2) Adjust the static water level using the automatic circulation pump.
(3) Set test parameters via the touch screen: nominal capacity, flow measurement, test duration, calibration, and verification.
(4) Start the test; the system applies bending force to the catheter loop while measuring flow reduction.
(5) Monitor real-time force and flow data on the screen.
(6) The system automatically evaluates results, sounds an alarm if the catheter fails, and prints a report for record-keeping.
Maintenance Information
(1) Regularly clean the water circulation system and fixtures to prevent debris buildup.
(2) Calibrate the flow measurement system periodically to ensure accuracy.
(3) Avoid prolonged exposure to direct sunlight or excessive moisture.
(4) Inspect electrical connections and sensors for wear or damage.
(5) Follow standard electrical safety procedures during operation.
Send product request
Other supplier products
| Bone Plates Static Four-Point Bending Tester | ISO 9585 ASTM F382 | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard (1)YY/T 0342-2022: Chinese standard specifying methods for determin... | |
| Geosynthetic Clogging Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The geosynthetic material clogging test apparatus is a testing instrument used for testing ... | |
| CE certified geosynthetic clogging tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The method of gradient ratio is used to measure the permeability... | |
| HEPA Filter Element Quality Control Test SystemEN 1822-3 HEPA and ULPA filter testing System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The HEPA Filter Element Quality Control Test System is designed for quality control of smal... | |
| Dry and Wet Retroreflectometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Dry and Wet Retroreflectometer, also known as the Dry and Wet Sand Abrasive Wear Testin... |