BBA steady state solar simulator tester for automotive materials

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The simulator complies with key international standards:

(1) GB/T 6495.3 – Solar Radiation – Measurement of Spectral Irradiance Distribution

(2) IEC 61215 – Crystalline Silicon Terrestrial Photovoltaic Modules – Design Qualification and Type Approval

(3) IEC 61646 – Thin-Film Photovoltaic Modules – Design Qualification

(4) IEC 60904-6 – Photovoltaic Devices – Procedures for Using Reference Cells and Simulators

Parameters

ItemTechnical Specification
Effective Test Area 2.0 × 1.0 m
Simulator Class BBA
Spectral Match Class B
Irradiance Uniformity Class B
Instantaneous Instability Class A
Light Source Type Metal halide lamp
Measurable Parameters NOCT, STC, Hot Spot
Light Source Lifetime Single lamp ~1000 hours, 1 spare set provided
Illumination Direction Top-down, vertical incidence on module
Consumables Lifetime Light source and filters for 2000 hours of use
Light Intensity Range 800 – 1000 W/m², continuously adjustable
Low Irradiance Testing Down to 200 W/m²
Operating Temperature +15°C to +30°C
Power Supply 380V, 50Hz, ≤150A
Software Features Simplified/Traditional Chinese, English; data storage, query, export/print; report output to Word, Excel, PDF, JPG
Supporting Equipment Dedicated computer for software operation

Features

Large-area BBA-class steady-state solar simulator suitable for full-size PV module testing

Strict Class B spectral match and uniformity compliance

High-precision light intensity adjustment (800–1000 W/m²) and low irradiance testing (200 W/m²)

Supports hotspot testing, temperature coefficient measurement, and light-induced degradation experiments

Long-life metal halide lamp with spare set ensures up to 2000 hours of operation

Multilingual software interface with full data acquisition, storage, analysis, and report generation

Accessories

(1) BBA Solar Simulator Main Unit – includes light source, lamp mount, and optical system

(2) IV Curve Tester – measures module current-voltage characteristics

(3) Control Software – data acquisition, display, and report generation

(4) Dedicated Computer – software operation and data management

(5) Consumable Metal Halide Lamp – single lamp ~1000 hours, 1 spare set provided

(6) Consumable Optical Filters – ensure spectral match and irradiance uniformity

(7) Optional Calibration Reference Device – IEC 60904-6 standard photovoltaic reference

Test Procedures

Configure test parameters: irradiance (800–1000 W/m²), temperature (STC or NOCT), and low irradiance (200 W/m²)

Mount the PV module on the test fixture and adjust angle for perpendicular incidence of light

Start the BBA steady-state solar simulator and stabilize illumination to the set conditions

Use the IV curve tester to record the module’s current-voltage characteristics

Conduct hotspot experiments, temperature coefficient measurements, and light-induced degradation tests

Collect test data, analyze maximum power, fill factor, efficiency, and electrical performance variations

Output and archive experiment reports for traceability


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

ISO 4892 U48AU Carbon Arc Fade Meter Factory Supplier
ISO 4892 U48AU Carbon Arc Fade Meter Factory Supplier Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM G153-13 Standard Practice for Testing Nonmetallic Materials U...
Axial force wire guide apparatus
Axial force wire guide apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YYT0807 - 2010 :Standard Guide for Measuring Securement of Balloon Expandable Va...
Anti slip coefficient tester machine
Anti slip coefficient tester machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)ASTM F2913 — Standard Test Method for Measuring the Coefficient of Fric...
UV Accelerated Weathering Chamber Manufacturer(ASTM Standard)
UV Accelerated Weathering Chamber Manufacturer(ASTM Standard) Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Ultraviolet Aging Test Chamber is a laboratory testing system specifically de...
High precision manikin cough generator for laboratory research
High precision manikin cough generator for laboratory research Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Manikin Coughing System (Cough Simulator) is a high-precision experimenta...
All supplier products

Same products

Laser Cutting Machines
Laser Cutting Machines Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer Seller: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 Seller: 868983 Common Rail Injector Valve F00R J02 012 David Chen