Helmets Vertical SpacingInfrared - positioning Tester
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
The helmet vertical spacing infrared positioning tester is a specialized instrument used to measure the vertical spacing and wearing height of safety helmets. It conforms to the GB/T 2812-2006 "Safety Helmet Test Methods" standard, and some models are compatible with the updated GB/T 2812-2024 standard.
Application
This measuring instrument is used to measure the vertical spacing and wearing height of safety helmets.
Standard
(1)GB/T 2812-2006:Test method of safety helmet
(2)GB 2811-2019:Head protection—Safety helmets
(3)EN 397:Protective helmets for industry
Features
(1)Digital display: Uses a digital display scale for intuitive readings and to avoid human error.
Modular design: Supports the replacement of different head forms, adapting to various safety helmet sizes.
(2)Efficient and convenient: Automated measurement process improves testing efficiency.
(3)Compliant with standards: Strictly adheres to domestic and international safety helmet testing standards.
Parameters
| Technical Parameter | Description |
|---|---|
| Digital height gauge | Can display height in real - time, with a measuring range of 0 - 500mm |
| Positioning method | Adopts infrared positioning |
| Sample preparation for measurement | First, wear the test sample on the head mold specified by the standard according to standard requirements, and adjust it so that the heights on both sides of the hat hoop are consistent |
| Wearing height measurement | Measure the vertical distance from the lowest point of the bottom edge of the hat hoop on the side of the sample to the top of the head mold as the wearing height, record the measured value with an accuracy of 1mm |
| Measurement of X1 | Measure the vertical distance from the position of the point on the edge of the minor axis of the helmet shell relative to the head mold to the top of the helmet shell as X1 |
| Sample re - placement for X2 measurement | Remove the wearing system and cushioning liners, place the sample on the head mold again, and ensure that the posture of the helmet shell is the same as before removal |
| Measurement of X2 | Measure the vertical distance between the same points as X2 |
Send product request
Other supplier products
| Camera test light box ISO 12233 | Standard ISO 12233: Compliant with SFR (Spatial Frequency Response) testing for lens resolution. IEC 62679: Photometric requirements for video ca... | |
| Geosynthetic Transmissivity Tester丨Geotextile Test Machine | Scope of application: It is used to measure the characteristics of the plastic drainage plate in the plane direction of the water flow under the s... | |
| Filter Media Tester G508(Without Vertical Duct) | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Filter Media Filtration Performance Test Bench G508 is designed to evaluate th... | |
| Helmet Strap Tensile Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The helmet strap tensile testing machine is designed to simulate tensile, impact, ... | |
| Car Crash Test Dummies(Hybrid iii Dummys) | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The “triple-collision dummies” do not refer to a single standardized t... |