Parameters
| Parameter Category | Details |
|---|---|
| Equipment Dimensions | 4350 mm × 2520 mm × 2150 mm (W × H × D) |
| Environmental Chamber Dimensions | 1800 × 1000 × 1000 mm (W × H × D) |
| Rated Power | 60 kW |
| Test Medium | Glycol/Water |
| Pressure Range | 0…5 bar |
| Medium Flow Control | Up to approx. 100 l/min |
| Linear Motion Parameters | ±25 mm at 1 Hz ±12 mm at 5 Hz ±6 mm at 10 Hz ±2 mm at 20 Hz |
| Test Medium Temperature Range | -40°C … +150°C |
| Environmental Temperature Control | -40°C … +150°C |
| Test Channels | 8 |
Accessories
Linear and eccentric motion drive unit
Environmental chamber with dual doors
Automatic leak detection sensors and safety shut-off
Coolant circulation and return pump
Windows/LabVIEW control system with data logging
Heating and temperature control modules
Test Procedures
Ensure installation space allows safe operation and access to all test channels.
Connect the system to the 60 kW power supply and ensure environmental temperature control is set.
Fill the system with glycol/water test medium.
Install the radiator, hose, or expansion tank in the test chamber.
Close front and rear doors to seal the chamber.
Set the desired pressure range, linear motion parameters, and temperature profiles in the control unit.
Start the test program via Windows/LabVIEW interface.
Monitor pressure, motion, temperature, and leak sensors throughout the test.
Automatically shut down any failed or leaking samples.
After testing, safely drain the test medium and allow the chamber to cool before removing samples.
Maintenance Information
Regularly inspect the motion drive, pressure sensors, and leak detection units for wear or damage.
Check glycol/water circulation system for blockages or leaks before each test.
Calibrate sensors and temperature controllers periodically to maintain measurement accuracy.
Clean environmental chamber surfaces and doors to prevent corrosion.
Replace worn seals, gaskets, or insulation as necessary to ensure safe operation.
Send product request
Other supplier products
| Computer-Controlled Intervertebral Fusion Cage Shear Fatigue Testing System | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YY/T 0959-2014 (China): Specifies shear fatigue testing protocols ... | |
| industrial grade clothing steamer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Industrial Dry Cleaning Machines: Suitable for cotton, wool, polyester, blen... | |
| Battery Nail Penetration Tester丨Battery Nail Penetration Test mechine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Description The test shall be carried out at an ambient temperature of 20°C±5&d... | |
| Glow Wire Test Machine, IEC 60695-2-10,automatic glow wire tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction: This machine is designedaccording to IEC60695-2-10: 2000 standard "glowing f... | |
| High-Temperature Curing Chamber,Curing And Drying Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com The High-Temperature Curing Chamber, also known as a drying or baking curing room, is a hig... |