CE Certified Steam Jet Test Equipment Factory Direct Price
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
All medium-contact parts are rust-resistant and suitable for deionized water.
Ceramic plunger pump with direct-drive motor ensures high safety and minimal wear.
Steam injection duration adjustable from 1 second to 9 minutes.
External pressure control valve allows precise adjustment depending on nozzle specifications.
Equipped with door inspection glass, dirt filters, and exhaust port for safe operation.
Automatic sterilization/water replacement system with temperature control.
Electromagnetic door locking ensures safety during pump operation.
Heating vessel with digital temperature display and controlled preheating.
Parameters
| Parameter | Details |
|---|---|
| Flow Rate | 14.8 L/min |
| Working Pressure (P) | 30 – 140 bar (adjustable via external pressure valve) |
| Motor (N) | 6.5 kW, 400 V |
| Plug | 32 A, 5-pole |
| Water Supply | 2 – 3 bar, 15°C |
| Nozzle Distance | 0 – 450 mm |
| Test Angles | 90°, 45°, 30° ±2° |
| Other Components | Door with inspection glass, exhaust Ø 102 mm, connectors, discharge port with dirt filter |
| Base Frame | Stainless steel with enclosure and four guide rails |
| Sterilization/Water Replacement | Automatic weekly cycle: water heated to 68°C, sprayed through nozzles; stops at 70°C; manual water replacement possible. Cooling to working temperature required after sterilization, can be accelerated with cold water addition |
| Door Locking | Electromagnetic locking during pump operation; door cannot be opened while pump is running |
| Heating Vessel | 9.0 kW, max temperature 80°C ±2°C, digital display, preheat time 1 hour |
Accessories
Horizontal sliding unit
Exhaust fan
Laser pointer
Flow meter
Volume-measuring testing equipment (in liters)
Clamping device
Test Procedures
Install the component to be tested inside the chamber and connect the water supply.
Set the nozzle distance and test angle according to the manufacturer’s specifications.
Adjust working pressure via the external control valve.
Configure the steam injection duration on the display (1 second – 9 minutes).
Start the pump using the control unit; the door will automatically lock for safety.
Monitor real-time parameters including pressure, flow, and temperature.
After completion, allow the system to cool to working temperature; perform sterilization/water replacement if required.
Remove tested components and review recorded data for evaluation.
Maintenance Information
Inspect the pump and ceramic plunger for wear and proper operation.
Check pressure valves and flow control system for functionality.
Clean the chamber, inspection glass, and discharge filters regularly.
Perform weekly sterilization/water replacement cycles and monitor water quality.
Verify heating vessel operation and temperature calibration periodically.
Check electromagnetic door locking system for safety compliance.
Send product request
Other supplier products
| Molten Metal Penetration Resistance Test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 9185(Protective Clothing - Assessment of Resistance to Molten Metal Splash)... | |
| ASTM E809 Compliance Retroreflectometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports compliance with the following standards: GB 20653-2020 &nda... | |
| High-Temperature Reciprocating Friction and Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The High-Temperature Reciprocating Friction and Wear Tester is designed for quantitative ev... | |
| Femoral Stem Neck Prostheses Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0809.6 (China): Specifies neck fatigue testing for femoral stems in partial/... | |
| Material Fire Spread Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Flame Spread Calorimeter is suitable for: Building materials: Evaluate fl... |