IEC 60695-11-5 Automotive Wire Flame Test Equipment Supplier Factory Direct
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Features
Needle Burner Design: Φ0.5mm inner hole, 45° tilt angle for precise flame application.
Smart Touch Interface: Programmable control of combustion time (0–999.9s), flame height (12±1mm), and gas flow.
Flame Calibration: Auto-measures temperature rise (100°C→700°C in 23.5±1.0s) with K-type thermocouple.
Sample Bed: White pine board (10mm) + silk paper layer for realistic ignition testing.
Large Chamber: >0.5 m³ (customizable to 0.75/1 m³) with black background (<20 Lux).
Exhaust System: 100mm diameter pipe with silent anti-backflow design.
Technical Parameters
| Parameter | Specification |
|---|---|
| Burner Specs | Stainless Steel; Inner Φ0.5±0.1mm; Outer Φ0.9mm; Length >35 mm |
| Flame Angle | Vertical (Calibration) / 45° (Test) |
| Combustion Gas | 95% Butane/Propane |
| Flame Temperature | 100–700°C (Rise Time: 23.5±1.0s) |
| Test Time | 0–999.9s (Adjustable; Default: 30s) |
| Burning Time Recording | 0–9999s (Automatic) |
| Chamber Volume | >0.5 m³ (900×590×1050 mm); Custom Options: 0.75/1 m³ |
| Exhaust Pipe | Φ100 mm |
| Control System | PLC + 7-inch Touchscreen |
| Dimensions (W×D×H) | 1120 × 520 × 1250 mm |
| Net Weight | 80 kg |
| Power Supply | AC 220V ±10%, 50Hz |
| Temperature Range |
0–1000°C (K-Type Thermocouple) |
Test Procedures
The operating procedure for the needle flame tester includes the following key steps:
Preparation: Ensure the instrument is in good condition, all components are present, and the power cord and connecting cables are intact.
Setting test parameters: Turn on the instrument's power, enter the main menu, and set test parameters such as temperature, time, and oxygen concentration.
Sample preparation: Place the sample on the test platform, ensuring the sample is flat and undamaged.
Starting the test: Press the "Start" button to begin the test. Observe the test process to ensure it proceeds smoothly.
Test completion: Press the "Stop" button to end the test. Adjust the angle of the needle flame gun so that the flame is applied vertically to the tested material.
During operation, operators should be familiar with the structure, principle, and operating method of the needle flame tester, ensure that the distance between the sample and the needle flame nozzle meets the requirements, and pay attention to safety to avoid accidents.
Send product request
Other supplier products
| Catheter Guidewire Friction Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for a wide range of medical devices and scenarios, inc... | |
| Tabletop Xenon Arc Weathering Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This equipment enables accelerated aging testing for various high-performance ... | |
| Carpet Static Electricity Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test Principle When a person walks on the inspected carpet wearing the shoes specified in ... | |
| Gloss Meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard The SpectroColor Pro S Series Gloss Meter adheres to stringent automotive interio... | |
| Adiabatic Accelerating Rate Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Battery Safety Research: Evaluating the thermal runaway characteristics of bat... |