Parameters

ItemSpecification
Number of Burners 12 proportional flat-flame burners (6 on each side, 5 m furnace length)
Operating Temperature Maximum test temperature 1250 °C
Design Temperature 1350 °C
Combustion Mode Low-speed proportional flat-flame diffusion combustion
Gas & Air Pressure ≤ 4000 Pa
Flame Length ≤ 500 mm
Furnace Temperature Measurement Points 9 points
Thermocouple Sleeve Extension ≥ 25 mm
Temperature Accuracy < ±15 °C
Furnace Pressure Measurement T-type probes, accuracy ±2 Pa, 3 points
Data Acquisition Rate 3 times per second
Fuel Gas Liquefied petroleum gas
Equipment Dimensions 8 m (W) × 8 m (L) × 2.5 m (H)
Power Supply AC 380 V, 70 kW
Equipment Weight Approx. 5 t

Features

Robust Furnace Structure

Frame-type enclosure with refractory bricks and high-temperature insulation fiber ensures thermal stability while minimizing heat loss to the surrounding environment.

Safe and Accessible Operation Design

Steel platforms are installed around the furnace for convenient operator access and maintenance.

Advanced Combustion Safety Protection

Automatic flame-out detection with visual and audible alarms; the system cuts off LPG supply to the affected burner while other burners continue operating.

Reliable Gas Supply and Control System

Equipped with gas solenoid valves, proportional valves, pressure transmitters, ball valves, regulators, and filters to ensure stable and safe gas delivery.

Precise Air–Fuel Ratio Control

Combustion air is supplied by a dedicated blower with frequency inverter for airflow adjustment, ensuring optimal combustion conditions.

Independent Control System

Dedicated control components manage combustion processes and simulate standard fire curves accurately.

Automatic Temperature Curve Tracking

Real-time comparison between actual furnace temperature and the preset fire curve, with automatic correction via burner output adjustment.

Comprehensive Data Recording

All automatic control and test data are stored in the computer system for traceability and accuracy verification.

Accessories

(1) Proportional flat-flame burners

(2) Gas solenoid valves and proportional valves

(3) Combustion air blower with frequency inverter

(4) Gas pressure regulators and filters

(5) T-type furnace pressure probes

(6) High-temperature exhaust fan with inverter

(7) Programmable logic controller (PLC) system

(8) Computer-based control and data acquisition system

Test Procedures

Install the horizontal test specimen securely in the furnace opening according to the test configuration.

Set test parameters through the control system, including fire curve, test duration, and safety limits.

Start the combustion system and initiate the standard fire exposure.

Monitor furnace temperature, pressure, and combustion status in real time via the computer interface.

The control system automatically adjusts burner output to maintain the specified temperature curve.

Upon test completion, shut down the gas supply and allow the furnace to cool before specimen removal.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Yellowing resistance test chamber
Yellowing resistance test chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com The yellowing resistance test chamber, a key testing device in the field of materials scien...
Ross Flex Tester
Ross Flex Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Ross Flex Tester evaluates the zigzag resistance and flex fatigue performance of sole m...
Automatic catheter bending resistance apparatus
Automatic catheter bending resistance apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for a wide range of medical devices, including: (1) Ur...
KES-SESRU surface roughness/friction tester
KES-SESRU surface roughness/friction tester Whats/App: +86 156 1874 6768 Web: standard-groups.com TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by art...
Button Impact Machine
Button Impact Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards: ASTM D5171: Test Method for Abrasion Resistance of Inks and Coatings (reference...
All supplier products

Same products

ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire Seller: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...