High-efficiency filter scanning test bench
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The system supports and complies with the following standards:
(1) GB/T 14295-2019 – Air filters.
(2) GB/T 13554-2020 – High-efficiency air filters.
(3) GB/T 6165-2021 – HEPA filter performance: efficiency and resistance.
(4) ISO 29463-4 – HEPA filter leakage testing.
(5) ISO 29463-5 – HEPA filter overall separation efficiency testing.
(6) EN 1822-4 – HEPA filter leakage testing.
(7) EN 1822-5 – HEPA filter overall separation efficiency testing.
(8) ISO 14644-3 – Cleanroom air filtration system testing.
(9) IEST-RP-CC034 – Standardized HEPA and ULPA filter testing.
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test Flow Rate | m³/h | 120 – 5000 |
| Differential Pressure Measurement | Pa | 1000 |
| Test Sample Dimensions | mm | Max 1830 × 1220 × 300 |
| Aerosol Operating Medium | – | DEHS, PSL |
| Gas/Air Supply | bar | 6 |
| Power Supply | – | 3 × 400 VAC, 100 A |
Features
Fully Automated Filter Scan: Multiple scanning probes enable short test cycles and minimal operator intervention.
Standard-Compliant Test Reports: Automatically generates ISO 29463-4/EN 1822-4 reports.
Flexible Filter Adapter: Accommodates various filter dimensions with quick-change adapters.
User-Friendly Software: STD150Win simplifies control, data acquisition, and analysis.
Accurate Leakage Detection: Particle counters provide precise detection beyond traditional photometers.
Automated Workflow: Reduces manual operations, improves efficiency, and enables real-time results display.
Data Management & Backup: Automatic storage and backup ensure data integrity and traceability.
Remote Access: Supports remote diagnostics, debugging, and calibration.
Accessories
| Accessory | Quantity |
|---|---|
| Filter Media Test Instrument | 1 |
| Filter Adapter | 1 |
| Test System Software | 1 |
Test Principle
Sample Installation: The filter is mounted in the filter holder, ensuring a secure fit.
Aerosol Generation & Flow: Aerosol (DEHS or PSL) is introduced at a controlled volume through the filter.
Leakage and Efficiency Measurement: Downstream particle concentration is measured via particle counters to calculate overall filtration efficiency and identify potential leaks.
Automated Data Collection: PC-controlled software records upstream and downstream particle counts and calculates efficiency and leakage locations.
Operation Instructions
System Startup:
- Configure and start all devices, including aerosol generator, particle counters, and airflow system.
- Install filter adapter according to sample dimensions.
Testing Process:
- Launch test; the system scans the filter using multiple probes, measuring leakage and overall efficiency automatically.
Data Recording & Reporting:
- Software generates a standard-compliant report, including efficiency and leak position.
Experimental Procedure
Preparation Stage:
- Verify all devices are operational.
- Install filter in the appropriate adapter.
Testing Stage:
- System conducts automated scanning and efficiency/leakage measurement.
Result Analysis & Report Generation:
- Test results are automatically compiled and saved in the software, including filter efficiency, potential leaks, and compliance with standards.
Maintenance Information
Regularly clean aerosol generators and scanning probes.
Verify particle counters and sensors for calibration accuracy.
Inspect adapters and seals to prevent leaks affecting measurement.
Send product request
Other supplier products
| Backsheet Scratch Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is widely applied in: PV Module Backsheet Scratch Resistance Test... | |
| Compression Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0959-2014 (China): Specifies compression fatigue testing protocols for inter... | |
| Coatings Shear Fatigue Tester | ASTM D3165 Adhesion Test Machine | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)YY/T 0988.13-2017 (China): Specifies shear fatigue testing prot... | |
| Rotary reciprocating friction and wear testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM G99 – Standard Test Method for Wear Testing ASTM G133 – High-T... | |
| Industrial Flow Testing Instrument for Quality Control ISO/ASTM | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Pressure Transmission and Flow Tester is widely used in multiple fields a... |
Same products
| Filter Efficiency Testing Equipment | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFilter Efficiency Testing Equipmentis ... | |
| G506 Filter Performance Tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM F2100:Standard Specificat... | |
| Automated Filter Integrity Tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb... | |
| High Efficiency Oil Water Separation Tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth... | |
| DIN 51524 hydraulic oil analyzer | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c... |