Pinch Valves

Pinch Valve is made up of two parts: the upper side is the body, and the lower side is the connection that can hold the pipe. Keytopinch valve has three series. The mainly different is the port size. The port size means the pipe diameter you want to use.

In addition to port size, we have many functions to choose from. like single port or dual port, and different installations and different voltages to meet your unique needs.

Types of Pinch Valves

Pinch Valve 1213

Double Channel Pinch Valve, the medium only resists in the tube and little cross contamination, tube size recommend: 1.5mm*3mm/1.6mm*3.2mm.

Pinch Valve 1224

Single Channel Pinch Valve, the medium only resists in the tube and little cross contamination, tube size recommend: 2mm*4mm.

Pinch Valve 1269

Single Channel Pinch Valve, the medium only resists in the tube and little cross contamination, tube size recommend: 6mm*9mm.

Advantages of Pinch Valves

01

Hose easily cleaned, ideally for testing impurity sample, waste discharge

02

Suitable for inspecting samples contain impurities / particles or not

03

Applications in occasion which need to avoid cross contamination between samples

What is a Pinch Valve Used for?

Keytos' pinch valve uses are as follows:

Keyto mainly offers the series 1224, 1213 and 1269 pinch valves. The pinch valves are typically used in applications such as the discharge of samples containing impurities (especially flocculent impurities) or particles, the pre-treatment of water samples, electrolyte instrumentation, and the pharmaceutical industry. The 1269 series of pinch valves are mainly used in the environmental industry.

FAQs of Pinch Valves

Can a pinch valve regulate flow?

The pinch valve cannot be used to regulate flow because it is only available in two states, fully open or fully close, and the degree of opening cannot be adjusted at will.

How doe s a pinch valve stop flow?

Two types of solenoid pinch valveare available: N.C. and N.O.

Normally open valve(N.O.): the solenoid is powered to drive the pressure plate action, then the pressure plate clamps hose tightly, so as to stop the flow. Normally open valve(N.C.): the initial state of a normally close valve is that of a stop-flow, and the stop-flow principle is the same as that of a normally open valve. The difference is that normally open valve stops flow when powered on and normally closed valve stops flow when powered off.

What are the components of pinch valve?

Main components of the pinch solenoid valve: solenoid, valve body, spring, moving iron core, hose pressure plate, mounting plate.


Send product request

To: SHENZHEN KEYTO FLUID CONTROL CO., LTD.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Keyto Microfludic & Consumables
Keyto Microfludic & Consumables To fight the COVID-19 outbreak, lots of global diagnostics companies bring high-capacity PCR test machine which requires huge consumables including...
Customized Machining
Customized Machining Super precision components are Key to Keyto's cutting-edge product lines. A 3mm Diameter 316 Stainless Steel filler shown below is demonstrating...
Syringe Pumps / Piston Pumps
Syringe Pumps / Piston Pumps 50XX series automated syringe pumpis a precision piston pump independently developed by Keyto. Its primary function is to achieve precision samplin...
Air Displacement Pipettes
Air Displacement Pipettes Air displacement pipettingis a pipetting module developed by Keyto based on pneumatic aspiration and dispense technology with disposable tips for p...
Air Displacement Pipettes
Air Displacement Pipettes Air displacement pipette and positive displacement pipetteis a pipetting module developed by Keyto based on pneumatic aspiration and dispense techn...
All supplier products

Same products

Advanced technology Electric regulating valve T967H-64 for thermal power plant
Advanced technology Electric regulating valve T967H-64 for thermal power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Advanced technology Electric regulating valve T967H-64 for thermal power plant The use of advanc...
High Security Superheater outlet plug valve SD61H-P54.5150V for power plant
High Security Superheater outlet plug valve SD61H-P54.5150V for power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "High Security Superheater outlet plug valve SD61H-P54.5150V for power plant Deyang YOYIK is a st...
Low Failure Rate Bellows valves WJ10F-1.6 for power plant
"Low Failure Rate Bellows valves WJ10F-1.6 for power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Low Failure Rate Bellows valves WJ10F-1.6 for power plant Deyang Dongfang Yoyik is a trade produ...
Customized Check valve H42H-16C for power station
Customized Check valve H42H-16C for power station Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "Customized Check valve H42H-16C for power station Our company is equipped with high-precision cu...
Save Maintenance Costs Electric stop valve J961Y-P51150V for thermal power plant
Save Maintenance Costs Electric stop valve J961Y-P51150V for thermal power plant Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD Save Maintenance Costs Electric stop valve J961Y-P51150V for thermal power plant YOYIK profession...