Polypectomy Snares (Hot)
This device indicated for use endoscopically for the removal of polyps.
Features of Hot PolypectomySnares (Hot)
Snares are available in multiple shapes, stiffness ranging from 'soft' to 'Hard', as well as full range snare open width to meet different polyps cutting requirement.
Braided wires for excellent coagulation and bleeding control.
360° 1:1 rotation for precise adjustment.
Specification of Snare Polyp(Hot)
Rgeular items
|
REF |
Catheter |
Snare |
Stiffness |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
||
|
L16CA241815A0 |
L16RA241815A0 |
1800 |
15 |
Oval |
Soft |
10 |
|
|
L16CA241825A0 |
L16RA241825A0 |
1800 |
25 |
||||
|
L16CA241832A0 |
L16RA241832A0 |
1800 |
32 |
||||
|
L16CA242415A0 |
L16RA242415A0 |
2400 |
15 |
||||
|
L16CA242425A0 |
L16RA242425A0 |
2400 |
25 |
||||
|
L16CA242432A0 |
L16RA242432A0 |
2400 |
32 |
||||
|
L16CB241822A0 |
L16RB241822A0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832A0 |
L16RB241832A0 |
1800 |
32 |
||||
|
L16CB242422A0 |
L16RB242422A0 |
2400 |
22 |
||||
|
L16CB242432A0 |
L16RB242432A0 |
2400 |
32 |
||||
|
L16CC241825A0 |
L16RC241825A0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832A0 |
L16RC241832A0 |
1800 |
32 |
||||
|
L16CC242425A0 |
L16RC242425A0 |
2400 |
25 |
||||
|
L16CC242432A0 |
L16RC242432A0 |
2400 |
32 |
||||
|
L16CA241815B0 |
L16RA241815B0 |
1800 |
15 |
Oval |
Hard |
||
|
L16CA241825B0 |
L16RA241825B0 |
1800 |
25 |
||||
|
L16CA241832B0 |
L16RA241832B0 |
1800 |
32 |
||||
|
L16CA242415B0 |
L16RA242415B0 |
2400 |
15 |
||||
|
L16CA242425B0 |
L16RA242425B0 |
2400 |
25 |
||||
|
L16CA242432B0 |
L16RA242432B0 |
2400 |
32 |
||||
|
L16CB241822B0 |
L16RB241822B0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832B0 |
L16RB241832B0 |
1800 |
32 |
||||
|
L16CB242422B0 |
L16RB242422B0 |
2400 |
22 |
||||
|
L16CB242432B0 |
L16RB242432B0 |
2400 |
32 |
||||
|
L16CC241825B0 |
L16RC241825B0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832B0 |
L16RC241832B0 |
1800 |
32 |
||||
|
L16CC242425B0 |
L16RC242425B0 |
2400 |
25 |
||||
|
L16CC242432B0 |
L16RC242432B0 |
2400 |
32 |
||||
What is a Hot Snare Polypectomy
Hot snare polypectomy, the endoscopist advances the snare sheath, opens the snare and encircles the polyp. The snare is then slowly and progressively closed, with the aim of capturing 1-2 mm of normal tissue around the polyp,then use Electrocoagulation until complete closure is achieved and the polyp emris guillotined. Best used for polyps 10-19 mm in diameter.
Hot Snare Polypectomy Technique
Hot endoscopic snare polypectomy, which is using electrocoagulation on the basis of using cold snare. After hot snare polypectomy, another independent endoscopic surgeon judged whether the endoscopic eradication was successful. Afterward, additional EMR was performed at the polypectomy site to evaluate for the presence of residual polyp tissue,including an additional 1 to 2 mm clear margin, was resected by the snare and Endocut current after submucosal injection of a mixed solution.
Snare Polypectomy Procedure
In snare polypectomy, doctor will capture around the bottom of the polyp and use current to cut the growth off. Any remaining tissue or stalk is then cauterized.
Endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) techniques could be used on some polyps are considered more technically challenging or are associated with an increased risk of complications.
As one of endoscopy device companies, we will offer more types of related products for sale, anything you need, please leave us a message.
Send product request
Other supplier products
| Single-use Biopsy Forceps | Used for endoscopic tissue sampling from digestive tract and respiratory tract. Features of Single-use China Biopsy Forceps Variety of configur... | |
| Pulmonology Products | Leo Medical Co.,Ltd. is committed to providing affordable and qualified endoscope accessoriesin Gastroenterology, Respirology, as well as the medic... | |
| Gastroenterology Equipment | LeoMed, one of the most professional gastroenterology equipment manufacturers, is committed to developing and producing specific gastroenterology p... | |
| ERCP Accessories | ERCP(endoscopic retrograde cholangiopancreatography) procedure is a procedure to diagnose and treat diseases in biliary duct and pancreas mostly. ... | |
| LeoMed Instruments Used in Endoscopy | For quality living and good health, LeoMed contributes to developing disposable endoscopic instrumentsfor assisting the surgery of diagnosis, inter... |
Same products
| R404a Scroll Compressor for Cold Chain Transportation | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |