Malaria (p.f/pan) Antibody Rapid Test
Malaria (Malaria) is an infectious disease caused by plasmodium parasites in the human body. Infected by malaria mosquito bites or transfusion of the blood of a person carrying malaria parasites. Different malaria parasites cause vivax, vivax, falciparum, and ovarian malaria respectively. Malaria is mainly manifested as periodic and regular attacks, with body chills, fever, and hyperhidrosis. After a long period of repeated attacks, it can cause pelvic blood and splenomegaly. Children have a high morbidity rate, mostly in summer and autumn. The mortality rate of falciparum malaria is extremely high. Therefore, it is very important to reduce the time to eliminate through detection.
Intended Use of malaria pf pan rapid test
The pf pan malaria test kit(Whole Blood) is a rapid chromatographic immunoassay for the qualitative detection of two kinds of circulating Plasmodium falciparum (P.f.) and Plasmodium vivax(P.v.) in whole blood.
General Description of Malaria (pf pan) Antibody Rapid Test
Malaria is caused by a protozoan which invades human red blood cells.1Malaria is one of the world's most prevalent diseases.
According to the WHO, the worldwide prevalence of the disease is estimated to be 300-500 million cases and over 1 million deaths each year. Most of the victims are infants, young children. Over half of the world's population lives in malarious areas. Microscopic analysis of appropriately stained thick and thin blood smears has been the standard diagnostic technique for identifying malaria infections for more than a century.2The technique is capable of accurate and reliable diagnosis when performed by skilled microscopists using defined protocols. The skill of the microscopist and use of proven and defined procedures, frequently present the greatest obstacles to fully achieving the potential accuracy of microscopic diagnosis.
Although there is a logistical burden associated with performing a time-intensive, labor-intensive, and equipment-intensive procedure such as diagnostic microscopy, it is the training required to establish and sustain competent performance of microscopy that poses the greatest difficulty in employing this diagnostic technology. The Malaria P.f./P.v. Rapid Test Device (Whole Blood) is a rapid test to qualitatively detect the presence of the P. falciparumspecific HRP-II antigens and/or Pan-malarial Lactate Dehydrogenase antigens found in P. falciparum (P.f), and P. vivax (P.v.).
The test utilizes colloid gold conjugate to selectively detect P.f-specific and P. vivax (P.v.)-specific antigensin whole blood.
The Test Principle of Malaria (p.f/pan) Antibody Rapid Test
The Malaria P.f./P.v. Rapid Test Device (Whole Blood) is a qualitative, membrane based immunoassay for the detection of P.f and P.vantigens in whole blood. The membrane is precoated with anti-HRP-II antibodies and anti-pLDH antibodies. During testing, the whole blood specimen reacts with the dye conjugate, which has been pre-coated on the test strip. The mixture then migrates upward on the membrane by capillary action, reacts with anti-Histidine-Rich Protein II (HRP-II) antibodies on the membrane on P.f Test Line region and with anti-pLDH antibodies on the membrane on P.v. Line region.
If the specimen contains HRP-II or Plasmodium-specific P.vivaLDH or both, a colored line will appear in P.f line region or P.v. line region or two colored lines will appear in P.f line region and P.v. line region. The absence of the colored lines in P.f line region or P.v. line region indicates that the specimen does not contain HRP II and/or Plasmodium-specific P.vivaLDH. To serve as a procedure control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
As one of the one step rapid test manufacturers,we provide cea test kit, pan malaria card, roller assembly machine, etc. Want to know more, contact us.
Send product request
Other supplier products
| Goat Anti Rabbit IgG | Goat anti rabbit antibody IgG AP Alkaline phosphatase (AP) , our company is dedicated to provide you with rapid, high quality and economic immunohi... | |
| COVID-19 Ag Test | COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel corona-virus a... | |
| Goat Anti Mouse IgG | This antibody is a high-quality secondary antibody, which is immunized with purified goat mouseIgG and purified by affinity column and adsorbed by ... | |
| Food Safety Rapid Test | Frenovo provides our customers with high-quality products, services, and overall solutions to tackle current and emerging food safety problems, pro... | |
| Mouse Anti Human IgM | Mouse Anti Human IgMis often applied in EIA, LF, Fluorescent, and it is recommend to use for coating. Specification ofMouse Anti Human IgM ... |
Same products
| R404a Scroll Compressor for Cold Chain Transportation | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |
















