Single-use Balloon Dilatation Catheter (Rapid Exchange) Progressive Dilation Balloons
Pyloric balloon dilationis used to dilate strictures of the biliary duct and the alimentary tract.
Features of Single-use Balloon Dilatation Catheter (Rapid Exchange) Progressive Dilation Balloons
Radiopaque markers enable precise placement.
Soft and tapered tip allows less invasive pass the stricture.
Lower profile balloon folding process optimize its passability.
Multi-size dilation balloon for esophageal, pyloric, colonic and biliary applications.
Three distinct diameters of balloon could cover widely clinical requirements.
Semi-compliant material engineered to adapt to biliary duct.
Side port on catheter achieves rapid exchange of the devices during procedure.
Specification of Single-use Balloon Dilatation Catheter (Rapid Exchange) Progressive Dilation Balloons
|
REF |
Balloon |
Catheter |
Minimum Working Channel (mm) |
Unit/Box |
||||
|
Length |
Nominal Pressure |
Length |
Structure |
|||||
|
(mm) |
(mm) |
(atm) |
(mm) |
(mm) |
||||
|
KZ0430E1 |
30 |
2004/5/6 |
3-4.5-6 |
1800 |
RX |
1 |
||
|
KZ0630E1 |
30 |
2006/7/8 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ0830E1 |
30 |
2008/9/10 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ1030E1 |
30 |
2010/11/12 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ1255G1 |
55 |
12-13.5-15 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ1555G1 |
55 |
15-16.5-18 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ1855G1 |
55 |
18-19-20 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ2055G1 |
55 |
20-21-22 |
2003/4/5 |
1800 |
RX |
|||
|
KZ1580F1 |
80 |
15-16.5-18 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ1880F1 |
80 |
18-19-20 |
3-4.5-6 |
1800 |
RX |
|||
|
KZ2080F1 |
80 |
20-21-22 |
2003/4/5 |
1800 |
RX |
|||
|
KZ0430H1 |
30 |
2004/5/6 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ0630H1 |
30 |
2006/7/8 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ0830H1 |
30 |
2008/9/10 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ1030H1 |
30 |
2010/11/12 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ1255H1 |
55 |
12-13.5-15 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ1555H1 |
55 |
15-16.5-18 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ1855H1 |
55 |
18-19-20 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ2055H1 |
55 |
20-21-22 |
2003/4/5 |
2400 |
RX |
|||
|
KZ1580H1 |
80 |
15-16.5-18 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ1880H1 |
80 |
18-19-20 |
3-4.5-6 |
2400 |
RX |
|||
|
KZ2080H1 |
80 |
20-21-22 |
2003/4/5 |
2400 |
RX |
|||
If you want to know more details of basket stone retrieval, please visit our website.
LeoMed, a professional endoscope accessoriesmanufacturer, established by returnee in 2011, is dedicated to developing and producing cost-effective, high-quality endoscopic device in Gastroenterology, Pulmonology and Peripheral Vascular.
Send product request
Other supplier products
| Single-use Biliary Draining Tubing | Used for endoscopic retrograde biliary drainage. Features of Single-use Biliary Draining Tubing Whole drainage tube has clear contrast image unde... | |
| Single-use Biliary Drainage Catheter | Used for endoscopic retrograde biliary drainage. Features of Single-use Biliary Drainage Catheter Whole drainage tube has clear contrast image ... | |
| PTA Balloon Dilatation Catheter | ThePTA Dilatation Catheteris used for PTA(Percutaneous Transluminal Angioplasty) procedure in the peripheral vasculature, including but not limited... | |
| Single-Use Airway Retrieval Basket | This bronchoscopic basketis used for endoscopic removal of foreign bodies from airway. Features of Single-Use Airway Retrieval Basket The bro... | |
| Single-use Nasal Biliary Drainage Catheter | Used for temporary endoscopic catheterof the biliary duct through the nasal passage by use of an indwelling catheter. Features of Single-use Nasal... |