Shine i1910 Fully Automatic Chemiluminescence Immunoassay Analyzer
Shine i1910 is a fully automatic and simple-to-use benchtop chemiluminescence immunoassay analyzerwith a throughput of 120 tests per hour. Based on various modes of antigen-antibody immunoreactivity and with paramagnetic particles as a carrier, i1910 utilizes the indirect chemiluminescence reaction of AMPPD with alkaline phosphatase to realize catalytic cracking of AMPPD under the action of enzymes. As a fully automated clia immunoassay analyzerwith high quality, Shine i1910 with the characteristics of simplicity, reliability and flexibility, which can help optimize your laboratory analysis performance.
Automated Chemiluminescence Immunoassay Analyzer Features
◆ Innovative design: Incubation, washing and detection all-in-one.
◆ Fast: first result in 15 mins.
◆ Good repeatability: Batch CV≤8%.
Automatic Clia AnalyzerSpecifications
Sample Type |
Human serum and plasma samples |
Throughput |
Test speed up to 120 tests / hour |
Assay cup |
Disposable assay cup |
Sample position |
30 |
Reagent position |
10 |
Reagent refrigeration |
24h refrigeration, reagent disk temperature: 2 °C ~8 °C |
Temperature stability of reaction disk |
37 ℃± 0.3 ℃, and the temperature fluctuation should not exceed 0.2℃ |
Repeatability within batch |
CV ≤ 8% |
Carry-over |
≤10-5 |
Linear correlation |
r ≥ 0.99, the concentration range is not less than 2 orders of magnitude |
Dimensions (mm) L×W×H |
433×679×638 |
Net weight (kg) |
62 |
Clia Immunoassay Analyzer Test Items
Tumor Markers |
|
Name |
|
Carcinoembryonic Antigen Quantitative Diagnostic Kit (CLIA) |
CEA |
Neuron-specific Enolase Quantitative Diagnostic Kit (CLIA) |
NSE |
Carbohydrate Antigen 19-9 Quantitative Diagnostic Kit (CLIA) |
CA19-9 |
Carbohydrate Antigen 15-3 Quantitative Diagnostic Kit (CLIA) |
CA15-3 |
Carbohydrate Antigen 50 Quantitative Diagnostic Kit (CLIA) |
CA50 |
Cytokeratin 19-fragments Quantitative Diagnostic Kit (CLIA) |
CYFRA21-1 |
Cancer Antigen 125 Diagnostic Kit (CLIA) |
CA125 |
Fertility |
|
Name |
|
Estradiol Quantitative Diagnostic Kit (CLIA) |
E2 |
Luteinizing Hormone Quantitative Diagnostic Kit (CLIA) |
LH |
Follicle Stimulating Hormone Quantitative Diagnostic Kit (CLIA) |
FSH |
Prolactin Quantitative Diagnostic Kit (CLIA) |
PRL |
Testosterone Quantitative Diagnostic Kit (CLIA) |
TES |
Total β Human Chorionic Gonadotrophin Quantitative Diagnostic Kit (CLIA) |
Tβ-hCG |
Progesterone Quantitative Diagnostic Kit (CLIA) |
PROG |
Placental Growth Factor Diagnostic Kit (CLIA) |
PLGF |
Soluble Fms-like Tyrosine Kinase-1 Diagnostic Kit (CLIA) |
sFlt-1 |
Chemiluminescence Immunoassay Analyzer Principle
Based on various antigen-antibody immunoreaction modes, the full automatic hemiluminescence immunoassay analyzer takes paramagnetic particles as the carrier, and makes use of the direct chemiluminescence method of acridinium ester. It produces unstable intermediates in excited state under the action of free energy released in chemical reaction. When the intermediates get back to the ground state from the excited state, the photons with the same energy level are released. At this point, it measures such photons and thus conducts the quantitative analysis. The luminescent intensity of the reaction is proportional to the concentration in the sample within the detection range.
As one of chemiluminescence immunoassay analyzer manufacturers, we will do our best to meet all the needs of customers.
We can offer kinds of digestive testing kitfor sale, if you have needs, please contact us.
Send product request
Other supplier products
Detection Kit for 2019-nCoV (PCR-Fluorescence) | Detection Kit for 2019-nCoV (PCR-Fluorescence) CE Respiratory infections are associated with various symptoms, including runny nose, congestion, ... | |
Human Papillomavirus Types 16 and 18 Fluorescent Polymerase Chain Reaction Diagnostic Kit | HPV genotype 16 and 18 types cause 70% of cervical cancers and pre-cancerous cervical lesions. This hpv dna pcr testis used to qualitatively detect... | |
Molecular Diagnosis | Why Is Molecular Diagnosis Important? Molecular diagnosis is the application of molecular biology to detect the structures or expression level cha... | |
Gastrointestinal Infections | What is Gastrointestinal Infections? Digestive infections are caused by some viruses, bacteria, or parasites leading to digestive organ inflammati... | |
Diagnostics Kit For Quantification Of Human Immunodeficiency Virus Type 1 HIV 1 PCR Fluorescence Probing | Diagnostics Kit For Quantification Of Human Immunodeficiency Virus Type 1 HIV 1 PCR Fluorescence Probing NMPA Based on the fluorescent PCR techni... |
Same products
Glycine™ Microcatheter | Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | OVERVIEW Glycine™ neurovascular microcatheters Glycine™ Neurovascular microcatheter... | |
High Pressure PTA Balloon Catheter | Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | OVERVIEW High Pressure PTA Balloon Catheter Deliver great outcomes for both AV and vascular acc... | |
Drug Coated PTA Balloon Catheter | Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | OVERVIEW Drug Coated PTA BalloonCatheter ENSURE EFFECTIVE DRUG DELIVERY OF A SAFE THERAPEUTIC D... | |
Matador Distal Access Guiding Catheter | Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | OVERVIEW Matador Distal Access Catheter 95cm/105cm/115cm Working Lengths ”/0.078&rdq... | |
Cylone™ Aspiration Catheter | Seller: ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD. | OVERVIEW Cylone™ Aspiration Catheter The Cylone™ aspiration catheter, featuring an ... |