Bone Screw Static Torque Testing Machine

Standard

  • YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedullary nails, including torque application, angular displacement measurement, and failure criteria.
  • ASTM F1264: International standard covering mechanical testing of intramedullary fixation devices, with protocols for static and quasi-static torsion tests.

Product Advantages

  1. Precision Torsional Control:
    • Electromagnetic servo-controlled torsion system ensures torque application with ±0.1% accuracy, adhering to ASTM F1264’s resolution requirements.
    • Adjustable torque range (0.1–500 Nm) and rotational speed (0.01°–360°/min) for versatile testing scenarios.
  2. Customized Fixturing:
    • Modular torsion clamps with interchangeable collets (6–16mm diameter) and anti-slip mechanisms to accommodate diverse nail diameters and lengths.
    • Specimen alignment guides ensure consistent angular displacement measurements.
  3. Advanced Data Acquisition:
    • Real-time monitoring of torque, angular displacement, and shear modulus with 5000Hz sampling rate.
    • Automatic calculation of key parameters: torsional rigidity (Nm/°), yield torque (Nm), and failure angle (°).
  4. User-Centric Design:
    • Intuitive software with preloaded SOPs for YY/T 0591 and ASTM F1264 compliance.
    • Multi-language interface (English/Chinese/Spanish) and exportable reports (PDF/Excel/CSV).
  5. Durability & Safety:
    • Corrosion-resistant steel frame and overload protection system for long-term reliability.
    • Low-noise operation (<65 dB) suitable for laboratory environments.

Product Features

  • Torque Capacity: 0.1–500 Nm (torsional).
  • Torque Resolution: 0.001 Nm.
  • Angular Accuracy: ±0.01°.
  • Testing Modes:
    • Torsional rigidity (ASTM F1264).
    • Yield torque and failure angle (YY/T 0591).
    • Load-deflection curve analysis.
  • Software Suite:
    • Customizable test profiles with automated pass/fail criteria.
    • 21 CFR Part 11 compliance for audit trails and electronic signatures.
  • Calibration: NIST-traceable certification included, with annual recalibration available.

Technical Parameters

ParameterSpecification
Torque Range 0.1–500 Nm (torsional)
Angular Resolution 0.001°
Rotational Speed 0.01°–360°/min
Power Supply 220V/110V, 50/60Hz
Dimensions (W×D×H) 600×500×1,600 mm
Weight 250 kg
Compliance CE, ISO 13485, YY/T 0591, ASTM F1264

Accessories (Included/Optional)

  • Standard Kit:
    • Torsion clamps (6mm, 10mm, 16mm collets).
    • Calibration weights and torque wrench.
    • Test control software with preloaded SOPs.
  • Optional Upgrades:
    • Axial-torsional load frame (for combined loading tests).
    • Environmental chamber (for thermal cycling tests).
    • Custom fixturing for pediatric/specialized intramedullary nails.
    • Remote diagnostics and preventive maintenance package.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Battery diaphragm permeability tester
Battery diaphragm permeability tester Meet the standard: GB/T458, ISO536/2, QB/T1667, GB/T23227, ISO2965, YC/T172, GB/T12655, S05636/3, IS05636/5, GB/T20042.7-2014, GB/T36363-2018, ...
BBA steady state solar simulator tester
BBA steady state solar simulator tester Standard IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval IEC 61646: Thin-Film Terrestrial Photo...
Mask Synthetic Blood Penetration Tester
Mask Synthetic Blood Penetration Tester Medical masks synthetic blood penetration tester is used to determine the resistance of medical protective masks to penetration by synthetic blood ...
Auto ignition Point Liquids Tester
Auto ignition Point Liquids Tester Standards: This product complies with GB/T 21860 - 2008 *Test Method for Auto - ignition Temperature of Liquid Chemicals* and ASTM E659 - 78(2005)...
Femoral Stem Neck Prostheses Fatigue Testing Machine
Femoral Stem Neck Prostheses Fatigue Testing Machine Standard YY/T 0809.6 (China): Specifies neck fatigue testing for femoral stems in partial/total hip arthroplasty. ISO 7206-6 (International): D...
All supplier products

Same products

Air Permeability Tester STD- F8
Air Permeability Tester STD- F8 Seller: Standard International Group (HK) Limited The Air Permeability Tester is designed to quickly and accurately measure the breathability and p...
Surface Performance Tester STD-FB4 - A
Surface Performance Tester STD-FB4 - A Seller: Standard International Group (HK) Limited Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti...
Compression Tester STD - FB3 - A
Compression Tester STD - FB3 - A Seller: Standard International Group (HK) Limited TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar...
Single - Strand Bending Tester STD - FB2 - SH
Single - Strand Bending Tester STD - FB2 - SH Seller: Standard International Group (HK) Limited Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ...
Bending Tester STD- FB2 - S
Bending Tester STD- FB2 - S Seller: Standard International Group (HK) Limited Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig...