Battery Diaphragm Gas Permeability Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Battery Diaphragm Gas Permeability Tester is a precision instrument designed to evaluate the gas permeability of battery diaphragms and separators. It provides accurate, high-resolution measurements under controlled pressure conditions, enabling reliable assessment of materials used in battery production. The compact design and ease of operation make it suitable for laboratory and quality control environments.
Application
(1) Measuring gas permeability of battery diaphragms and separators in lithium-ion and other rechargeable batteries.
(2) Evaluating barrier performance of separator materials for battery safety and efficiency.
(3) Research and development of new diaphragm and separator materials.
(4) Quality control and inspection in battery manufacturing facilities.
(5) Laboratory testing for material science studies related to electrochemical devices.
(6) Comparing permeability of different separator types to guide material selection.
Standards
(1) GB/T 458 – Battery diaphragm gas permeability test method.
(2) ISO 536/2 – Paper and board determination of gas permeability.
(3) QB/T 1667 – Battery separator testing requirements.
(4) GB/T 23227 – Lithium-ion battery separator testing.
(5) ISO 2965 – Determination of gas permeability for thin films.
(6) YC/T 172 – Battery separator gas transmission test.
(7) GB/T 12655 – Testing of diaphragms for battery applications.
(8) GB/T 20042.7-2014 – Lithium-ion battery separator performance testing.
(9) GB/T 36363-2018 – Gas permeability test for battery diaphragm materials.
Features
(1) High-accuracy measurement of gas permeability (10–15000 s/100ml).
(2) Exceptional resolution (0.1 s/100ml) and pressure accuracy (0.0001 kPa).
(3) Multiple selectable pressure ranges: 5 kPa standard, 10 kPa and 20 kPa optional.
(4) Single-sample testing with secure sample holder.
(5) Compact, robust design suitable for laboratory environments.
(6) User-friendly interface for easy parameter setting and operation.
(7) Requires only clean air as a test gas.
(8) Provides reliable and repeatable results for quality control and R&D applications.
Parameters
| Parameter | Specification |
|---|---|
| Test range | 10–15000 s/100ml (standard, other ranges optional) |
| Resolution | 0.1 s/100ml |
| Pressure accuracy | 0.0001 kPa |
| Number of samples | 1 |
| Net weight | 20 kg |
| Test gas | Clean air (user-supplied) |
| Power supply | AC 220V, 50Hz |
| Overall dimensions | 370 mm (L) × 320 mm (D) × 450 mm (H) |
| Pressure range | 5 kPa standard (10 kPa, 20 kPa optional) |
| Air source pressure | 0.3–1.0 MPa |
Accessories
(1) Main testing machine
(2) Sample holder
(3) Pressure application system
(4) User manual
(5) Power cable
Test Procedures
(1) Install the battery diaphragm or separator sample securely in the sample holder.
(2) Connect the clean air source to the machine and ensure proper pressure supply.
(3) Select the test pressure and configure the test parameters.
(4) Start the test; the machine measures the time required for 100 ml of gas to pass through the sample.
(5) Read and record the permeability value from the high-resolution display.
(6) Repeat the test for additional samples as needed.
Maintenance Information
(1) Regularly inspect the sample holder and pressure components for wear or leaks.
(2) Keep the instrument clean and free from dust or debris.
(3) Check the air source for contaminants that may affect test accuracy.
(4) Periodically verify calibration to maintain measurement precision.
(5) Handle the machine carefully to avoid damage to sensitive components.
(6) Follow manufacturer guidelines for servicing and spare parts replacement.
Send product request
Other supplier products
| Bag lifting fatigue testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is suitable for up and down vibration fatigue test of plastic handbag, garbage... | |
| Total Hip Joint Prostheses Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0651.1-2016 (China): Specifies wear testing parameters for total hip prosthe... | |
| Mechanical load testing machine for photovoltaic modules | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mechanical Load Testing Machine for Photovoltaic Modules is engineered to evaluate the ... | |
| ASTM D7027 Scratch Testing Equipment for Automotive & Plastic OEM Supplier Factory Direct | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application: Scratch tester used for a variety of automotive interior materi... | |
| Affordable fire protection coating chamber test | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The fire-retardant coating tester (combustion chamber method) is primarily us... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | Seller: Kelilong Electron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | Seller: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... |