Diaper impurity testing machine
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Diaper Impurity Testing Machine is designed for visual inspection of disposable diapers under controlled lighting conditions to detect residual fibers, particles, or foreign matter. It provides accurate and reliable results, supporting quality control, batch inspection, and research in the hygiene product industry.
Application
This instrument is suitable for impurity detection in a wide range of hygiene products:
Disposable diapers
Baby pants and training pants
Adult incontinence diapers
Sanitary napkins
Absorbent underpads
Wet wipes
Plastic-backed hygiene sheets
Laboratory research on raw materials and finished hygiene products
Evaluation of new absorbent materials and hygiene product designs
Standards
The instrument complies with multiple national and international standards:
(1) GB/T 28004.1-2021 Appendix C – Baby diaper impurity detection
(2) GB/T 28004.2-2021 Appendix C – Sanitary napkin inspection
(3) ASTM F2512 – Standard Test Method for Visual Inspection of Hygiene Products
(4) ISO 11948-1 – Absorbent hygiene product impurity evaluation
(5) JIS T 8130 – Disposable diaper testing
(6) EN 14619 – Disposable diaper residual foreign matter evaluation
Feature
(1) Adjustable LED light source with 0.01 lx to 8000 lx illumination.
(2) Durable electrostatic spray-painted surface, easy to clean.
(3) Imported aluminum brushed control panel with robust metal keys.
(4) Optimized platform and lighting for efficient impurity detection.
(5) User-friendly interface for simple visual inspection.
Parameters
| Parameter | Specification |
|---|---|
| Light source intensity | 0.01 lx – 8000 lx |
| Specimen placement plane | Polyethylene plate |
| Platform size | 300 mm × 250 mm |
| Power supply | AC 220V, 50 Hz, 80 W |
| Overall size | 420 mm × 370 mm × 600 mm (L × W × H) |
| Weight | 25 kg |
Accessories
Standard accessories:
Main unit
Portable carrying case
User manual
Optional accessories:
USB data output
Bluetooth data output
Test Procedures
(1) Prepare the instrument and press the power/selection button to turn on the device.
(2) Press the power/selection button to select the desired measurement mode: visible light transmission, three-light cycle, ultraviolet light transmission, or infrared light transmission. The instrument retains the last used mode after shutdown.
(3) Confirm calibration before measurement. Recalibrate if previous calibration is in doubt; calibration results are automatically stored.
(4) Position the instrument over the sample; the measurement value will be displayed. Avoid operating under strong ambient light.
(5) After measurement, press the power button until “OFF” appears to shut down the device.
Maintenance
(1) Keep the instrument clean; wipe the surface with a soft, dry cloth.
(2) Regularly check the LED light source for consistent illumination and replace if necessary.
(3) Store in a dry environment, avoiding direct sunlight and high humidity.
(4) Ensure proper calibration before extended use.
(5) Avoid exposure to corrosive substances or strong mechanical shock.
Send product request
Other supplier products
| Cargo Compartment Liner Burn-Through Fuel Test System,Aviation fuel fire penetration test system | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cargo Compartment Liner Burn-Through Fuel Test System is a specialized aviation fire te... | |
| ASTM E662 smoke density tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument conforms to the following national and international standards: ... | |
| Fabric Snagging Performance Testing Machine for Apparel Quality Control | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The ICI Mace Snag Tester is a laboratory device used to evaluate the tendency... | |
| Safety Footwear Compression Puncture Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Test purpose Measure the compression resistance of the shoe head cover and the puncture re... | |
| Carpet tuft length measuring instrument | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard BS 4223:1989 (British Standard): Specifies methods for determining the pile len... |
Same products
| Large Naïve VHH Library | Seller: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Seller: Kelilong Electron Co.,Ltd | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... |