Residual Ethylene Oxide Gas Chromatography System

The Residual Ethylene Oxide Gas Chromatography System is a professional analytical instrument designed for the detection and quantification of residual ethylene oxide (EO) and its related compounds (ethylene chlorohydrin, ECH; ethylene glycol, EG) in medical products. It provides high sensitivity, accuracy, and compliance with international and national standards, ensuring the safety of sterilized medical devices and related products.

Application

The system is suitable for the analysis of residual ethylene oxide in the following industries and products:

(1) Medical Device Industry: surgical instruments, catheters, syringes, implants, and other sterilized medical equipment — residual EO detection

(2) Pharmaceutical Industry: sterilized vials, ampoules, and packaging materials — EO residue quantification

(3) Hospital Sterilization Facilities: EO-sterilized medical consumables, hospital sterilization quality control — monitoring residual EO levels

(4) Quality Control Laboratories: medical product manufacturers, third-party testing labs — EO residue compliance testing

(5) Research and Development: development of new sterilization processes, optimization of EO sterilization protocols

(6) Regulatory Compliance Testing: submission of data for ISO, USP, Ph. Eur., JP, and national pharmacopoeial requirements

Standards

The instrument is compliant with and suitable for use with the following standards:

(1) ISO 10993-7:2021 – Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals

(2) United States Pharmacopeia (USP) – relevant chapters for chromatography and biocompatibility testing

(3) European Pharmacopoeia (Ph. Eur.) – e.g., 2.2.28 Gas Chromatography for sterilizing agent residues

(4) Japanese Pharmacopoeia (JP) – residual solvent and sterilizing agent testing methods

(5) National Standards – e.g., GB/T 16886.7 (China) for EO residual testing

Features

(1) High Accuracy and Sensitivity: Detects trace levels of EO, ECH, and EG in ppm or µg/g ranges

(2) Compliance Assurance: Meets ISO 10993-7, USP, Ph. Eur., and other pharmacopoeial requirements

(3) Reliable Detection: Hydrogen Flame Ionization Detector (FID) ensures robust and consistent results

(4) Automated Sample Preparation: Optional headspace samplers improve reproducibility and operator safety

(5) Comprehensive Data Analysis: Advanced software provides chromatograms, quantitative results, and reporting

(6) Ensures Product Safety: Monitors residual toxins to protect patients and healthcare workers

(7) Modular Design: Six independent temperature-controlled zones, modular chambers for easy installation and replacement

(8) Precise EPC Electronic Flow Control: 18 gas channels independently controlled for flow and pressure

(9) Power-Off Protection: Automatic parameter memory and immunity to sudden power fluctuations

(10) Extensive Self-Diagnosis: Real-time fault detection with suggested solutions

(11) Fully Integrated Control Workstation: Three digital and three analog outputs for comprehensive control

Technical Parameters

ItemSpecification
Gas Flow Control EPC electronic control, 18 independent channels
Injector Up to 3 independently temperature-controlled injectors
Temperature Control Zones 10 independent zones, including column, vaporization, FID, thermal conductivity, auxiliary 1 & 2
Detector Hydrogen Flame Ionization Detector (FID), high sensitivity
Power-Off Protection Automatic parameter memorization, power fluctuation immunity
Self-Diagnosis Real-time fault messages with solutions
Control Workstation Fully integrated, 3 digital + 3 analog outputs
Safety Automatic stop functions and modular design for easy replacement

Accessories

(1) Gas chromatograph column(s) suitable for EO/ECH/EG detection

(2) Headspace sampler (optional, automated)

(3) Injector liners and septa

(4) Hydrogen and air supply lines with regulators

(5) Data acquisition software with quantitative analysis module

(6) Calibration gas kits

(7) Operation manual

(8) Maintenance toolkit

(9) Power cable

Test Procedures

(1) Prepare sample according to the target product type and standard requirements

(2) Load sample into headspace vial or GC injector system

(3) Configure the GC method parameters including temperature zones, flow rates, and detector settings

(4) Start automated or manual analysis

(5) Acquire chromatograms and record quantitative residual EO, ECH, and EG values

(6) Verify results against pharmacopoeial limits (ISO 10993-7, USP, Ph. Eur.)

(7) Clean injector, column, and sampling system after testing

Maintenance Information

(1) Regularly clean injector, column, and detector chambers

(2) Replace septa, liners, and GC columns as recommended

(3) Verify calibration with standard gases before each batch of testing

(4) Maintain gas supply lines and regulators for consistent flow

(5) Keep software, logs, and calibration records updated for compliance documentation

(6) Store instrument in a clean, dry laboratory environment


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

UV Accelerated Weathering Tester
UV Accelerated Weathering Tester Standard: ASTM D4329、ASTM D4587、ASTM D4799 、ASTM D5208、ASTM G151、ASTM G154 、EN 927-6、EN 1297 、EN 1898 FIBC、EN 12224 、EN 13523-10 、ISO 4892-1、ISO 4...
Sleeping Bag Flammability Tester -ASTM F1955
Sleeping Bag Flammability Tester -ASTM F1955 Standards: ASTM F1955.CPAI 75 Application: Sleeping Bag Flammability Tester, to determine the flammability resistance of sleeping bag. Both manu...
Fogging Tester,automotive interior fogging tester,6 station mist tester
Fogging Tester,automotive interior fogging tester,6 station mist tester Fogging Tester is mainly used to test the evaporation of volatile components in materials such as interior plastic parts of automobiles and aircraf...
Battery diaphragm permeability tester
Battery diaphragm permeability tester Meet the standard: GB/T458. ISO536/2. QB/T1667. GB/T23227. ISO2965. YC/T172. GB/T12655. S05636/3. IS05636/5. GB/T20042.7-2014. GB/T36363-2018. et...
Sliding Bearing PV Friction Coefficient Measuring Device
Sliding Bearing PV Friction Coefficient Measuring Device Standard This machine is mainly applicable to GB 7948-1987 plastic bearing limit PV test method, JB/T 7381-2010 powder metallurgy oil bearing PV v...
All supplier products

Same products

Full-Body Garment Stress Tester,FZ/T 70015
Full-Body Garment Stress Tester,FZ/T 70015 Seller: Standard International Group (HK) Limited TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe...
Industrial Dry Cleaning Machine,industrial garment steamer
Industrial Dry Cleaning Machine,industrial garment steamer Seller: Standard International Group (HK) Limited TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel...
MST Medical Compression Stocking Tester,compression sock tester
MST Medical Compression Stocking Tester,compression sock tester Seller: Standard International Group (HK) Limited The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the...
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool
MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool Seller: Standard International Group (HK) Limited Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi...
Dental material color stability tester
Dental material color stability tester Seller: Standard International Group (HK) Limited Application The applications of color stability testers for dental materials are mainly reflecte...