Catheter Airflow Resistance Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Catheter Airflow Resistance Tester is a precision testing instrument specifically designed for measuring the airflow resistance of catheters.
Applications
The catheter airflow resistance tester is an important tool for evaluating the resistance of gas flow in catheters. It is specifically designed to measure the airflow resistance inside medical devices such as breathing catheters. It is widely applied in multiple fields, including medical care, environmental protection, and the chemical industry. Especially in the production and quality - control processes of medical devices, this tester plays a crucial role. Through testing, it can ensure that catheter - related products like breathing tubes can meet the predetermined performance standards, thereby improving the overall product quality and production efficiency. In the medical field, the tester is used to assess the performance of breathing circuits for anesthesia machines and ventilators, ensuring that the products meet relevant standards and requirements.
Standards
YY0461 - 2003:Technical Requirements for Protective Masks for Medical Use
Features
Embedded Linux operating system, secure, efficient, and durable.
Get both English and Chinese input capabilities for the same price.
Non-standard customized services to create exclusive equipment tailored to your company.
Expand to various testing projects by changing dedicated custom fixtures.
Personalized input of production units and batches to obtain original production reports.
Processing speed up to 72MHz per second, testing resolution improved to 0.0001.
Touchscreen control for easier operation and more intuitive data display.
Multiple specifications, one machine compatible with various applications, automatic generation of test reports.
Onboard printer for quick printing of test results.
Real-time display of test pressure values, automatic power off in case of overload, and automatic data storage upon power failure.
Three-level password protection for secure and reliable information.
Technical Parameters
| Parameter | Specification |
|---|---|
| Pressure Measurement Range | Usually 0.01kPa to 10kPa; error ≤ ±1%; display resolution: 0.01kPa. This range covers airflow resistance measurement requirements for most catheters. |
| Flow Measurement Range | Typically 0L/min to 50L/min (varies by tester model), enabling airflow resistance testing of catheters under different flow conditions. |
| Test Duration | Usually 1 second to 10 minutes; error ≤ ±1 second. This range ensures test accuracy and stability. |
| Accuracy | Pressure measurement accuracy: ±0.01kPa; flow measurement accuracy: ±2.5% (or lower, depending on specific model). |
Accessoriess
Standard accessories: Dedicated clamps/connectors for different diameter tubes, airflow connecting tubing, sensor calibration parts, operating manual, and calibration certificate.
Optional accessories: Sample fixing bracket (for assisting tube installation), data export cable (for some models).
Test Procedures
1. Preparation
Ensure the instrument is in normal working condition and check that the power cord, sensors, and other components are intact. Connect the tubing and ensure a good seal between the tubing and the instrument interface.
2. Setting Parameters
According to the test requirements, set the relevant parameters of the instrument, such as flow rate and pressure measurement range.
3. Starting the Test
Start the instrument to begin the test. The instrument will automatically inject gas into the tubing and measure the pressure difference between the inlet and outlet. Based on the measurement results, the instrument will calculate the airflow resistance of the tubing.
4. Data Recording and Analysis
After the test is completed, the instrument will output the test results. The operator should carefully record this data and analyze it to evaluate the performance of the tubing.
Send product request
Other supplier products
| Model Coin-cell Swelling System | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM E83: Standard Test Method for Verification of Linear Displacement Measurin... | |
| Professional Sole Heat Resistance Testing Equipment Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The sand bath component of the Shoe Heat Insulation Tester is primarily used ... | |
| Pinhole Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The pinhole tester for aluminum foil is a device specifically used to detect micro - pinhol... | |
| UV Aging Test Chamber 450 X 450 X 450mm , Programmable Ozone Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Use of environmental test chamber Ozone Test chamberis used for testing rubber and polym... | |
| Helmet Xenon Aging Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2014-9-19. ISO 4892 ASTM G151. G154. D4329 d4587、d4799、sae j2020 Xenon la... |
Same products
| pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester | Seller: Kelilong Electron Co.,Ltd | Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent... | |
| ORP-2026S Waterproof Soil ORP and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| TDS-2616 Waterproof EC/TDS/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Range EC ~19.9mS TDS Temp 0~50℃ R... | |
| EC-98330 CF ECOstick - Nutrient Tester | Seller: Kelilong Electron Co.,Ltd | Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el... | |
| PH-808 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-808 Range PH ~14.00PH Temp 0~50℃ ... |