Bacterial Filtration Efficiency Tester
Standards:
YY 0469-2004 Technical requirements for surgical mask BS EN 14683-2014 Medical face masks - Requirements and test methods ASTM F2100-2019 Standard Specification for Performance of Materials Used in Medical Face Masks ASTM F2101 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus
Applications:
Mask Bacterial Filtration Efficiency Tester is applied to test the filtration efficiency of mask, can be used in metering calibration department, scientific research institution, mask manufacturer and other related departments.
Product Information:
Mask bacterial filtration efficiency (BFE) tester is mainly applicable to the measurement and verification departments, scientific research institutes, medical mask manufacturers and relevant testing departments for the performance of mask bacterial filtration efficiency.It is composed of aerosol generation system, aerosol chamber and aerosol transmission device, negative pressure cabinet and 28.3l /min sampler.The whole tester is controlled by the console.The control console adopts microcomputer control system to coordinate and control the work of aerosol generation system, transmission system, negative pressure cabinet and sampling system, and display the working status in real time. The whole measurement work is completed automatically.
| Main Parameter | Parameter range |
| vacuum pump | Oil-free rotary vane vacuum pump, maximum flow up to 57LPM, equipped with muffler, stable airflow |
| Aerosol generator flow control | The flow control of aerosol generator adopts mass flow control and the control is accurate |
| Channel I sampling flow | Anderson sampling flow of 28.3 L/min, resolution: 0.1 L/min |
| sampling flow | Anderson sampling flow of 28.3 L/min, resolution: 0.1 L/min |
| sampling | Equipped with mass flow controller |
| Pneumatic pressure | 0-5KPa |
| Spray flowmeter pressure | 0-300KPa |
| aerosol chamber negative pressure | 0-120KPa |
| Working Temperature | 0-50℃ |
| Cabinet negative pressure | 0-120Pa |
| Cabinet negative pressure | Data can be downloaded via usb flash drive |
| Data storage capacity | Data can be downloaded via usb flash drive |
| mass flow controller | 0-20L/min,resolution:0.1 L/min |
| Peristaltic pump flow | (0.01~3.0)mL/min |
| High efficiency air filter characteristics | The filtration efficiency of particles above 0.3um is≥99.99% |
| Median mass diameter of aerosol generator | The average particle diameter was(3.0±0.3)μm,Geometric standard deviation≤1.5 |
| Two-channel 6-stage Anderson sampler captures particle size | Ⅰclass>7μm,class(4.7~7)μm,Ⅲ class(3.3~4.7)μm,class(2.1~3.3)μm,class(1.1~2.1)μm,class(0.6~1.1)μm |
| Fog chamber specifications | (600×80×5)mm |
| Total number of positive quality control sampler particles | (2200±500)cfu |
| Ventilation flow of negative pressure system | 800m³/min |
| Operation room dimension | (740×940×440)mm |
| dimension | About 1200×650×2100mm |
| Instrument noise | <65Db(A) |
| weight | 120kg |
| power consumption | <1500W |
Send product request
Other supplier products
| Automatic Z-axis Vision Measuring Machine | Product Introduction: The Z-axis automatic image measuring instrument can efficiently detect the wheel corridors and surface shapes of various com... | |
| Respirator Fit Tester | PortaCount Respirator Fit Tester:Qinsun assesses the overall integrity of masks by performing an aerosol leak test utilizing the PortaCount Respira... | |
| Tibial Tray Fatigue Testing Machine | Standard YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total knee arthroplasty, focusing on support and protection ... | |
| Shoe heat insulation testing machine -- sand bath | Shoe heat insulation testing machine -- sand bath - Other test instrument - standard Product Information: Main uses: Evaluate the insulation per... | |
| Petroleum Products Kinematic Viscosity Tester | Meet the standard: ASTM D445 ISO 3104 IP 71 Product Introduction: The determination of kinematic viscosity is performed by measuring the tim... |
Same products
| Battery Diaphragm Gas Permeability Tester ISO | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Battery Diaphragm Gas Permea... | |
| Torsion Testing Tester ASTM, JIS, and DIN | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Universal Torsion Testing Ma... | |
| Wire Torsion and Winding Tester ASTM and JIS | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Wire Torsion and Winding Tes... | |
| Metal Wire Repeated Bending Tester ISO/DIS 7801 | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Metal Wire Repeated Bending ... | |
| Metal Wire Wrap Tester ISO 4101 | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Metal Wire Wrap Tester is de... |