Power Quality Analyzer SA2100
SA2100
SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system.
Brief Introduction
SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system. The PC software can simply upload the data to PC for full analysis.
Main Features
Waveform real-time display(4 voltages/4 currents)
Half-period RMS measurement (voltage and current)
Measurement of TRMS currents up to 5000A (sensor dependent)
Measurement, calculation and display of harmonics and interharmonics can be up to 50 times.
Transient capture
Active power, reactive power, apparent power and energy, shift power factor and true power factor
Three-phase unbalance (voltage and current)
Flicker
Inrush current
Detection and record of Dips& Swells, Voltage Rapid Change, Interruption.
Detect according to EN50160 or grid with user-defined limit
Data storage and screenshots (can be replayed or output to a PC)
Through the LAN interface PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data
Built-in 8G memory card
General Characteristics
Display |
|
Screen |
Color TFT LCD |
Size |
|
Resolution |
320×240 |
Brightness |
Adjustable |
Housing |
|
Protection |
Protection shield, strong |
IP |
IP51, accords IEC60529 |
Interface |
|
USB Host |
Download file to PC by U disk for analyze with PC software |
LAN |
For remote control of the Analyzer and measurement data transmission. |
Memory |
|
Flash Memory |
128MB |
TF Card |
Standard 8G |
Mechanical |
|
Dimension |
262× 173 × 66mm |
Weight |
|
Enviroment |
|
Working temperature |
0°C~ 40°C |
Storage temperature |
-20°C~ 60°C |
Humidity |
90% relative humidity |
Power |
|
Adapter input |
90~264V |
Adapter output |
12V 2A |
Battery |
Rechargeable NI-MH ion 7.2V 3.8Ah |
Battery Working Time |
undefined 7 hours |
Battery Charge Time |
4 hours |
Standard |
|
Measurement Method |
IEC61000-4-30 Class-S |
Measurement Performance |
IEC61000-4-30 Class-S |
Power Quality Monitoring |
EN50160 |
Flicker |
IEC61000-4-15 |
Harmonic |
IEC61000-4-7 |
Electrical Safety |
|
Comply with |
IEC61010-1 ,Safety Degree: 600V CAT IV 1000V CAT III |
600V CAT IV 1000V CAT III |
|
42Vpk |
Wire Combinations
1Ø+NEUTRAL |
Single phase with neutral |
1Ø SPLIT PHASE |
Split phase |
1Ø IT NO NEUTRAL |
Single phase system with two phase voltages without neutral |
3Ø WYE |
3-phase 4-wire system, Y type |
3Ø DELTA |
3-phase 3-wire system delta (Delta) |
3Ø IT |
3-phase Y type without neutral |
3Ø HIGH LEG |
4-wire 3-phase delta system (Delta) with center tapped high leg |
3Ø OPEN LEG |
Open-delta (Delta) 3-wire system with two transformer windings |
2-ELEMENT |
3-phase 3-wire system without current sensor on phase L2/B (2 Watt meter method) |
2 1/2-ELEMENT |
3-phase 4-wire system without voltage sensor on phase L2/B |
Input
Voltage Input |
|
Input Channels |
4 (3 phase + neutral) DC coupling |
1000Vrms |
|
Range of nominal voltage |
50 to 500V |
Max pulse peak voltage |
6kV |
Bandwidth |
undefined3kHz |
Input Impedance |
4MΩ/5pF |
Current Input |
|
Numbers of Input |
4 (3 phase + neutral) DC coupling |
Type |
Clamp Current Sensor with mV output |
Input Range |
1 to 3000Arms with supplied current clamp |
Input Impedance |
50kΩ |
Bandwidth |
undefined3kHz |
Sampling System |
|
Resolution |
8 channels 16 bits AD |
Sampling Rate |
20kS/s for each channel, 8 channels sample synchronously |
RMS Sampling |
5000 points for 10/12 cycles (according to IEC |
PLL Sync |
4096 points for 10/12 cycles (according to IEC61000-4-7) |
Measurement
Measurement Range |
Resolution |
Accuracy |
|
Voltage/Current/Frequency |
|||
Vrms(AC+DC) |
1 ~ 1000Vrms |
±0.5% of nominal voltage |
|
Vpk |
1 ~ 1400Vpk |
±0.5% of nominal voltage |
|
V(Crest Factor) |
±5% |
||
Arms (AC) |
1~ 1000A/3000A/5000A |
1A |
±1% ± 2A |
1~ 100A |
±1% ± 0.2A |
||
Apk |
1 ~ 4000Apk |
1A |
±1% ± 2A |
A(Crest Factor) |
1 ~ 10 |
±5% |
|
Frequency |
±0.01Hz |
||
51 ~ 69Hz (60Hz nominal) |
±0.01Hz |
||
Dips & Swells |
|||
Vrms1/2 |
0 ~ 200% of nominal voltage |
±1% |
|
Arms1/2 |
1 ~ 3000A |
1A |
±1% ±2A |
Threshold levels |
Threshold is settable according to nominal voltage percentage Detectable events type: Dips, Swells, Interruption, Voltage Rapid Change |
||
Duration |
hour-minute-second-microsecond |
1 period |
|
Harmonic |
|||
Harmonic Number |
1 ~ 50 |
||
Inter-Harmonic (SA2100) |
1 ~ 49 |
||
Harmonic Voltage |
±0.1% ± nx0.1% |
||
Harmonic Current |
±0.1% ± nx0.1% |
||
THD |
±2.5% |
||
DC Relative |
±0.2% |
||
Frequency |
0 ~ 3500Hz |
1Hz |
1Hz |
Phase |
-360° ~ 0° |
1° |
± nx1.5° |
Power and Energy |
|||
Active Power/Apparent Power/Reactive Power |
±1.5±10 digits |
||
Energe |
10Wh |
±1.5±10 digits |
|
Power Factor |
0 ~ 1 |
±0.03 |
|
Flicker (only for SA2100) |
|||
Pst(1min),Pst,Plt,PF5 |
±5% |
||
Unbalance |
|||
Voltage |
±0.5% |
||
Current |
±1% |
||
Voltage Phase |
-360° ~ 0° |
1° |
±2digits |
Current Phase |
-360° ~ 0° |
1° |
±5digits |
Voltage Transient (only for SA2100) |
|||
Vpk |
±6000Vpk |
1V |
±15% |
Vrms |
10 ~ 1000Vrms |
1V |
±2.5% |
50us |
|||
Sampling Rate |
20kS/s |
||
Inrush Current (only for SA2100) |
|||
Arms(AC+DC) |
0~3000Arms |
±1% ± 5digits |
|
Inrush Duration |
6s ~ 32min selectable |
10ms |
±20ms |
Logger |
|||
Recording |
user-defined parameters for 4 phases at the same time |
||
Memory |
Data stored in TF card, 8GB |
||
Duration Time |
2 hrs to 1 year |
||
Interval |
1s to 1 hrs |
Send product request
Other supplier products
Digital Multimeter SA5061 | SA5061 SA5061 is 6 1/2 digits, fast and high accuracy, multi-function and auto measurement instrument for Voltage, Current, Resistance, Frequency.... | |
SU4300 Series Noise Source | Synthesized Signal Generator TFG3630 Series Signal Generators TFG3630 synthesized signal generatorswith PLL technique and use the FPGA to control... | |
Function Generators | TFG3600 Combine with DDS and PLL techniques 1500MHz Maximum Frequency 1ppm High Accuracy, Less Distortion Dual Independent Outputs AM, FM, FSK... | |
Digital Multimeter SA5052 | SA5052 SA5052 is fast and high accuracy, multi-function and auto measurement instrument for Voltage, Current, Resistance, Frequency. The simple fr... | |
Programmable DC Power Supplies | SK10000 SK13530 programmable power supply is a new generation of programmable DC power supplies. It protects itself by warning and cutting off out... |
Same products
Energy Meter Application | Seller: Acrel Co.,Ltd. | Energy Meter Operation It has various functions such as remote measurement and remote signaling,... | |
DJSF1352-RN | Seller: Acrel Co.,Ltd. | DJSF1352-RN rail-mounted dc energy meter for solar systemwith double DC input channels, designed ... | |
Din Rail Energy Meter | Seller: Acrel Co.,Ltd. | Din Rail Energy Meter utilities to calculate electricity consumption and manage the electric dema... | |
3-Diff Hematology KT-60 | Seller: Genrui Biotech Inc. | 3-Diff Hematology KT-60 Genrui KT-60is an up-to-date hematology analyzerproviding smart counting... | |
Coagulation Analyzer CA54 | Seller: Genrui Biotech Inc. | Coagulation Analyzer CA54 CA54 is a touch screen semi auto coagulation analyzerwith 4 independen... |