Summary
The instrument is designed and made as per the national standard of People’s Republic of ChinaGB/T213-2008 Test Method for Calorific Value of coal,GB/T384-1988 Test Method for Calorific Value of Petroleum Productsand Calibration Regulation of People’s Republic of ChinaJJG672-2001 Oxygen Bomb Calorimeter, as well asShanghaienterprise standardQ/YXYY 10 XRY Series Oxygen Bomb Calorimeter.
I. Main technical features
1. The instrument adopts technology of single chip microcomputer and high performance A/D conversion device. It is a highly intelligent instrument.
2. The instrument is equipped with a brand notebook PC.
3. The test procedure is fully automatic. After placing sample and inputting right parameters, the instrument will finish all the procedures without manual interference. It will print the test data directly after test is finished.
II. Main technical specifications
1. Heat capacity: 14000 J/K~15000 J/K
2. Measuring range: (10~35)℃
3. Resolution: 0.001 K
4. Repeatability error: ≤0.2% (Grade C)
5. Pressure enduranceof oxygen bomb: 20 MPa
6. Ambient temperature: 10 ℃~28 ℃
7. Relative humidity: ≤85%
8. Power supply: AC 220V±5%, 50 Hz
9. Overall dimension: 600mm*460mm*430mm
(Note: The pellet press machine is optional accessory)
Send product request
Other supplier products
GDGS Automatic Transformer Capacitance Tester, Dissipation Factor Tester | 1PowerFactor Testerapplication GDGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation mate... | |
GDGS Good Quality Tan Delta Test Set for Power Transformers | 1PowerFactor Testerapplication GDGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation mate... | |
GDJ-8S Rotational Viscometer | I. Summary The instrument adopts advanced mechanical design technologies, manufacturing techniques, and microcomputer controlling techniques, so i... | |
GD-0610 Asphalt Rolling Thin Film Oven | Summary This instrument is designed and made as per industrial standardT 0610-2011 Standard Test Method for Effect of Heat and Air on a Moving Film... | |
GDGS Tan Delta Automatic Dielectric Loss Tester | 1PowerFactor Testerapplication GDGS automatic tangent delta tester is applied to measure the dielectric loss and capacitor value of insulation mate... |
Same products
Digital Rail Head Wear Gauge | Seller: Wuhan Linkage Track Equipment Co., Ltd | Rail wear gauge(rail head loss gauge also call it rail profile gauge)is mainly used to measure th... | |
Indicators | Seller: ZHEJIANG HAOYU INDUSTRY & TRADE CO.,LTD | Electronic Scales cannot be properly operated without suitable weighing indicator. Their design a... | |
HY001 Weighing Indicator | Seller: ZHEJIANG HAOYU INDUSTRY & TRADE CO.,LTD | Application of HY 001multiple Funcation Weighing Indicator with Printer HY001 must suitable for ... | |
Diaphragm Pressure Gauge | Seller: Lanso Instruments LLC. | Diaphragm pressure gauges are mainly used to measure the pressure of special media such as high-v... | |
SF6 Gas Density Switch | Seller: Lanso Instruments LLC. | Density switch is a kind of gas density monitor used to monitor the density of SF6 gas in a seale... |