E-Stop Button, Safety Gate Safety Relay
CHENZHU e stop safety relayare suitable for the application of emergency Stop button and safety gate. Support 2 safety output contacts (N/O) and 2 auxiliary output contacts (N/C) or 3NO+1NC or 2NO+2NC or 2NO+1NC+3NO(t)+1NC(t).
Safety monitoring relays can be operated in single or double channel mode, manual or automatic reset, and with the function of monitoring the short circuit between channels.
Features & Advantages of E-Stop Button, Safety Gate Safety Relay
Support single or dual-channel
Support instantaneous or delayed output
Support manual or automatic reset
Short circuit monitoring
Parameter of E-Stop Button, Safety Gate Safety Relay
|
CZSR8001-3A1B |
CZSR8001-3A1B(M) |
CZSR8002-2A2AT |
CZSR8002-2A2AT(M) |
CZSR8003-3A1B |
CZSR8001-2A1B |
CZSR8001-2A1B3AT1BT |
|
|
Supply voltage |
24V DC/AC |
24V DC/AC |
24V DC |
24V DC |
100V~230V AC |
24V DC/AC |
24V DC/AC |
|
Voltage tolerance |
|||||||
|
Current consumption |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤90mA (24V DC) / ≤240mA (24V AC) |
≤130mA (24V DC) |
≤130mA (24V DC) |
≤7 VA (220V AC) |
≤90mA (24V DC) / ≤240mA (24V DC) |
≤170mA (24V DC) / ≤400mA (24V AC) |
|
Input current |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
≤50mA (220V AC) |
≤50mA (24V DC) |
≤50mA (24V DC) |
|
Cable resistance |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
≤15Ω |
|
Input devices |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
E-stop buttons, Safety gates |
|
Number of contacts |
3NO+1NC |
3NO+1NC |
2NO+2NO(t) |
2NO+2NO(t) |
3NO+1NC |
2NO+2NC |
2NO+1NC+3NO(t)+1NC(t) |
|
Contact material |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 µm Au |
AgSnO2 |
AgSnO2 |
AgSnO2 + 0.2 µm Au |
AgSnO2 + 0.2 μm Au |
AgSnO2 + 0.2 μm Au |
|
External contact fuse protection |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO) |
10A gL/gG NEOZED (NO);6A gL/gG NEOZED (NC) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
10A gL/gG NEOZED (N/O);6A gL/gG NEOZED (N/C) |
|
Mechanical endurance of contacts |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
≥107 |
|
Utilisation category |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 3A/230V; DC-13, 3A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
In accordance with EN60947-5-1:AC-15, 5A/230V; DC-13, 5A/24V |
|
Switch-on delay |
≤300ms |
≤150ms |
≤300ms |
≤150ms |
≤300ms |
≤300ms |
≤300ms |
|
Delay-on de-energisation |
≤30ms |
≤30ms |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms (instantaneous);0.1s~3s (delayed, factory set as 3s) |
≤30ms |
≤30ms (instantaneous);- |
≤30ms (instantaneous)0s, 0.5s, 1s, 2s, 3s, 5s(delayed, factory set as 5s) |
|
Recovery time |
≤100ms |
≤100ms |
≤100ms |
≤100ms |
≤500ms |
≤100ms |
≤100ms |
|
Supply short interruption |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
20ms |
|
EMC |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
EN60947, EN61000-6-2, EN61000-6-4 |
|
Vibration |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
Vibration frequency: 10Hz~55Hz;Vibration amplitude: 0.35mm |
|
Ambient temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Storage temperature |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
-40℃~+85℃ |
|
Relative humidity |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
10%~90% |
|
Elevation |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
≤2000m |
|
Overvoltage category |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅲ |
Ⅱ |
Ⅱ |
Ⅱ |
|
Pollution degree |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
|
Rated insulation voltage |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
250V AC |
|
Rated impulse voltage |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
6000V (1.2/50us) |
4000V (1.2/50us) |
4000V (1.2/50us) |
|
Dielectric strength |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
1500V AC, 1min |
|
Clearance and creepage distance |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
In accordance with EN 60947-1 |
|
Safety integrity level |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
SIL3 |
|
Performance level |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
PLe |
|
Category |
Block Diagram of E-Stop Button, Safety Gate Safety Relay
Typical Applications of E-Stop Button, Safety Gate Safety Relay
Chenzhumanufactures the most reliable interface product for safety automation system. We are here to help your device run more safely. Here you can not only get world-class products, but also outstanding service for safety and automation system.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Safety Relay | Safety Relay Automation direct safety monitering relays are mainly applied to the safety control circuit, connecting the safety sensing elements a... | |
| Intrinsic Safety RTD TC Temperature Transmitter | Isolated intrinsically safe temperature transmitter, deliver the field thermocouple(TC) or thermal resistance(RTD) signal by digital linearization,... | |
| Photovoltaic 1000 DC Power SPD | SPD for DC power, SPD1000VDC; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication; Features & Advantages of Photovolta... | |
| The Working Principle and Classification of Surge Protector | Ⅰ. The surge protection device working principle Surge protection device is an indispensable device in lightning protection of electronic equipmen... | |
| Network SPD | The network surge protection deviceprotects a data line, including computer network signals, communication devices, and so on. Plug the network sur... |
Похожие товары
| Microcrystalline wax used for improving the flexibility of packaging materials | Продавец: Syntop chemical Co.,Ltd. | Microcrystalline wax is a specialty wax extracted from petroleum. Its primary functions include t... | |
| 288 Holes Plastic Plant Trays | Продавец: Hebei Marshine New Material Technology Co., Ltd. | 288 Holes Plastic Plant Trays 288 Holes Plastic Plant Trays of 288 holes are great for vege... | |
| plastic bag | Продавец: Hebei Marshine New Material Technology Co., Ltd. | plastic bag If you are a plant lover, you may have heard someone suggest putting a over a pl... | |
| Seedling Tray Price Philippines - Marshine | Продавец: Hebei Marshine New Material Technology Co., Ltd. | Seedling Tray Price Philippines - Marshine Seedling Tray Price Philippines - Marshine Find ... | |
| Seedling Trays | Продавец: Hebei Marshine New Material Technology Co., Ltd. | Seedling Trays Wholesale South Africa - Marshine Our seedling trays are exported to South A... |