AHKC-EKB hall split core current sensorcan collect main incoming line current, multi-channel branch DC current and leakage current. The split core hall effect current sensorconverts the primary side DC current into an analog signal and outputs it to the multi-loop monitoring device. The multi-loop monitoring device samples the analog signal and calculates the magnitude of the measured current.
Specification of AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE)
|
Parameter |
Description&Value |
|
Rated Input |
0~±(50-1000)A DC or 0~(50~1000)A AC |
|
Rated Output |
±5Vdc/±4Vdc |
|
Accuracy |
Class 1.0 |
|
Power Supply |
±15Vdc (allow ±20% fluctuation%) |
|
Consumption |
≤0.5W |
|
Zero Offset Voltage |
±20mV |
|
Offset Voltage Drift |
≤±1.0mV/℃ |
|
Linearity |
≤0.2%FS |
|
Response Time |
≤5us |
|
Bandwidth |
0~20kHz |
|
Isolation Voltage |
Features of AHKC-EKB (200-1000A)/5V Open-loop Hall Effect Transducer (Split-core)
01
It can measure DC, AC, pulse and various irregular waveform currents under electrical isolation conditions;
02
It is widely used in current monitoring and battery applications, inverter power supply and solar power management systems, DC panels and DC motor drives, electroplating, welding applications, inverters, UPS servo control and other system current signal acquisition and feedback control;
03
It has the advantages of fast response time, wide current measurement range and high precision, strong overload capacity, good linearity, and strong anti-interference ability.
Now the price of open loop hall effect current sensoris reasonable, if you are interested, please leave us a message.
As a power meter manufacturer, we will do our best to meet all the needs of customers.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| ACREL AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) | ACREL AHKC-EKB (200-1000A)/5V OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) AHKC-EKB hall split core current sensorcan collect main incoming line ... | |
| ACREL ACR10R-DXXTEX BIDIRECTIONAL THREE-PHASE REFLUX MONITORING ENERGY METER | ACR10R-DxxTEx bidirectional three-phase re-flux monitoring energy meter is equipped with external Rogowski coils and split-type transformers, which... | |
| ACREL AHKC-EKA OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) | ACREL AHKC-EKA OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) AHKC-EKA series open-type Hall current sensor is a new generation of current sensor d... | |
| ACREL AM2SE MEDIUM VOLTAGE RING MAIN UNIT PROTECTION RELAY | ACREL AM2SE MEDIUM VOLTAGE RING MAIN UNIT PROTECTION RELAY AM2SE medium voltage ring main unit protection relay is suitable for line protection an... | |
| ACREL AKH-0.66/P PROTECTION CURRENT TRANSFORMER | ACREL AKH-0.66/P PROTECTION CURRENT TRANSFORMER AKH-0.66/P protection ct and metering cttransformer is mainly suitable for the relay protection ci... |
Похожие товары
| Paddle wheel flow meter | Продавец: Beijing Gallop High& New Tech Co.,Ltd | A paddle wheel flow meteris an instrument that calculates flow rate based on the amount of rotati... | |
| Handheld ultrasonic flow meter | Продавец: Beijing Gallop High& New Tech Co.,Ltd | Handheld Ultrasonic Flow Meteris the smallest volume, the lightest weight, the most advanced tech... | |
| Turbine Flow Meter | Продавец: Beijing Gallop High& New Tech Co.,Ltd | Turbine flow metersare suitable for pure liquid flow measurement with an accuracy of up to 0.5% a... | |
| Vortex Flow Meter | Продавец: Beijing Gallop High& New Tech Co.,Ltd | This Type Of Vortex Flow Meterfrom Gallop,as industrial instrumentation supplier, is developed by... | |
| Hall Sensors | Продавец: Acrel Co.,Ltd. | Hall Sensors Hall sensor is suitable for uninterruptible power supply (UPS), switching power s... |