.

Air Disinfection Machine For Hospital And Medical

AIR DISINFECTION MACHINE   USER’S MANUAL           ZHEJIANG SUJING PURIFICATION EQUIPMENT CO.,LTD. Medical wall hanging mobile type air disinfection machine  ZJQ 40, ZJQ 100, ZJQ 150,ZJY 100 ,ZJY 150, ZJY 200,ZJY 300  1. Main characters  1.high intensity ultraviolet disinfection sterilization (personnel can work in the field of dynamic)  2.high concentration ozone disinfection sterilization (personnel should leave the scene, static)  3.light catalytic synergy high intensity ultraviolet disinfection sterilization  4.electrostatic adsorption  5.strongly activated carbon automatically adsorb to get rid of the smell.  6.stainless steel filter mask  7.negative oxygen ion to make air pure and clean.  8.ozone malfunction automatically detect alarm prompt  9.ultraviolet tube automatic fault detection alarm prompt 2.Technical parameters ModelSterilization space(m3)Ozone yield(mg/h)UV power(W)UV intensity(um/cm3Overall SizeZJQ-40 *225*115ZJQ-100 100300036*4896*298*195ZJQ-150 100500036*61080*340*210ZJY-100 100300036*4375*320*810ZJY-150 150500036*6440*440*1380ZJY-200 200700036*8460*250*1760ZJY-300 3001000036*12710*260*1800 3.Instructions 1.On 220V power supply, the red light turns on, this machine keeps into standby mode.2.Press the button of "ON/OFF", the red light turns into green and air door opens automatically ,blow out the nature wind. 3.Function button: it’s a cycle button. Press button once, " Sterilizing Mode 1", indicator light turn on and UV system works on(At this time for the dynamic, the staff can operate at the scene). Press button twice," Sterilizing Mode 2",indicator light turn on and machine turn into Ozone working mode(At this time for the static, the staff should leave the scene). Press button third time to stop disinfection function. Press the button of "ON/OFF" at this time, the fan would be delayed 30 seconds to shutdown. 4. The button of "Swing" control the switch of the swing and displaying of related light. 5. The button of "Timing" is cycle button, each time you press the increase for 0.5 hour,related light turns on,Maximum timing is 7.5 hours.


Отправить запрос, связаться с поставщиком

Кому: Zhejiang Sujing Purification Equipment Co.,Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

BSC-1000IIA2  Clean biological safety cabinet is necessary in animalcule lab, especially in the condition needing protection measure, such as me...
Commodity Model Specification Pictures particle counterY09-301ACPage 2Y09-301(AC/DC)Page 2Y09-310LCDPage 3Y09-310ACDCPage 3Y09-550Page 4  Air ...
XFH-30MA、40MA、50MA、75MA type electrothermic pressure Autoclave   Feature  ◆; Hand wheel type of quick-open door structure  ◆; Mechanical safety...
AIR DISINFECTION MACHINE   USER’S MANUAL           ZHEJIANG SUJING PURIFICATION EQUIPMENT CO.,LTD. Medical wall hanging mobile type air disinfecti...
Water-Jacket Thermostatic Constant Incubator  Specifications  1.Water-jacket heating mode  2.If power failure, the chamber can keep constant ...
Все товары поставщика

Похожие товары

Modbus RTU Over TCP Sensor IoT102
Modbus RTU Over TCP Sensor IoT102 Продавец: BLIIOT technology IoT102isultralowpower4GremoterelaycontrolmodulewhichcanbecontrolledremotelybyIoTcloudplatform.Ith...
Solderless Wire Joint Quick Splice Connector
Solderless Wire Joint Quick Splice Connector Продавец: LEDExtra This Hippo LED Strip to Wire Pitbull Snap Connector is a new designed for connecting 10mm LEDstri...
Krone Keystone Jack
Krone Keystone Jack Продавец: W And T Telecommunication CO.,LTD Krone Keystone Jack,Keystone Jack And Adaptor
RJ45 Keystone Jack
RJ45 Keystone Jack Продавец: W And T Telecommunication CO.,LTD RJ45 Keystone Jack,Keystone Jack And Adaptor
50 Pairs Distribution Box
50 Pairs Distribution Box Продавец: W And T Telecommunication CO.,LTD 50 Pairs Distribution Box,Distribution Box