Expansion Tank Static Pressure Test Machine,High pressure expansion tank static tester
The Expansion Tank Static Pressure Test Machine is a specialized system designed to evaluate the static pressure performance and leak resistance of automotive expansion tanks. You can adjust the static pressure from 0 up to a maximum of 5 bar, while controlling the flow rate of each sample from 0 to 8 liters per hour. The system includes indirect chamber heating for safety (Explosion Protection Level 1), automatic leak detection, and fail-safe shutdown of defective samples, providing a reliable and efficient solution for expansion tank testing.
Application
The Expansion Tank Static Pressure Test Machine is suitable for a variety of automotive component testing applications:
Expansion Tanks: Evaluate static pressure resistance, leakage, and functional performance.
Coolant System Components: Test caps, valves, and connectors under controlled static pressure.
Material Durability Testing: Assess long-term reliability of plastic, metal, and composite tank materials.
Quality Control: Ensure compliance with OEM and supplier specifications for automotive cooling systems.
R&D and Certification Testing: Support component development, validation, and system integration.
Typical test products include automotive expansion tanks, coolant reservoir tanks, and associated components requiring static pressure evaluation.
Standards
The system supports compliance with major automotive engineering standards:
VW TL889 (4.1) – Volkswagen Group technical specification for interior and related component functional performance.
ESDG93-8A080-AA (3.6) – Ford engineering specification for component functionality and reliability.
GMW15310 (3.2.1.2) – General Motors global standard for material and component performance testing.
QV17004D (3.2.6) – BMW group specification for system component functionality and durability.
Parameters
| Parameter Category | Details |
|---|---|
| Test Bench Dimensions | 2200 × 2240 × 1550 mm (W × H × D) |
| Chamber Dimensions | 1000 × 800 × 1000 mm (W × H × D) |
| Rated Power | 9.5 kW |
| Test Medium | Glycol/Water |
| Pressure Range | 0 … 5 bar |
| Flow Rate per Sample | 0 … 8 l/h |
| Pressure Type | Static |
| Test Medium Temperature Range | 25 … +150°C |
| Environmental Temperature Range | 25 … +150°C |
| Test Channels | 6 |
Features
Designed specifically for static pressure testing of expansion tanks.
Static pressure adjustable from 0 up to 5 bar.
Individual sample flow rate controllable from 0 to 8 l/h.
Explosion protection level 1 due to indirect chamber heating.
Automatic leak detection and leak testing with fail-safe shutdown of defective samples.
Automatic control of liquid level during testing.
Accessories
Indirectly heated test chamber
Flow control units for each sample
Leak detection sensors and safety interlocks
Liquid level monitoring and control system
Control unit with Windows/LabVIEW interface (optional for data logging)
Sample mounting brackets for expansion tanks
Test Procedures
Ensure the test area is clear and safe for operation.
Connect the system to the 9.5 kW power supply.
Fill the chamber and sample lines with glycol/water mixture.
Mount expansion tank samples in the test chamber.
Set the static pressure (0–5 bar) and flow rate (0–8 l/h) for each sample.
Activate the test system and indirect heating if required.
Monitor pressure, flow, and leak detection sensors throughout the test.
Automatically shut down any failed samples.
Record all test results for quality control or validation purposes.
After testing, safely drain the medium and allow the system to cool before removing samples.
Maintenance Information
Inspect sample mounting brackets, pressure sensors, and leak detection units before each test.
Verify flow control devices and chamber seals for proper operation.
Periodically calibrate pressure sensors and temperature controllers.
Clean the chamber and fluid circuits to prevent contamination.
Replace worn or defective components to maintain safe and accurate operation.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| STD Battery short-circuit tester | The Battery Short-Circuit Tester is designed for external short-circuit safety testing of lithium-ion batteries and battery packs. The system simu... | |
| In-situ expansion analysis system | Standard ASTM E83: Standard Test Method for Verification of Linear Displacement Measuring Systems ISO 12417-1: Mechanical Testing of Metals &nd... | |
| Dental Implants Fatigue Tester | Standard ISO 14801:2016: Specifies dynamic fatigue testing protocols for endosseous dental implants, including load ratios, frequency, and failure... | |
| Microbial Barrier Tester | Product Introduction: Y/T 0471.5-2017 is a newly updated standard, which specifies the experimental method for evaluating the bacteria-inhibiting ... | |
| Burning heat value tester for building materials,Building material combustion calorific value calorimeter | Scope of application: It is suitable for measuring the calorific value of solid and wavy combustible materials such as anthracite, bituminous coal... |
Похожие товары
| Damp Freeze and Thermal Cycling Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Damp Freeze and Thermal ... | |
| Alternative to BBA steady state solar simulator tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The BBA Steady-State Solar S... | |
| Alternative to PV Hail Impact Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Hail Impact Test Machine... | |
| Solar Panel Insulation Resistance Test Chamber | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is applicable in ... | |
| 90-Degree Peel Tester for PV Backsheets | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for e... |