Full-Scale Room Corner Fire Test Apparatus,Corner fire test rig for construction materials

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Full-Scale Room Corner Fire Test Apparatus is designed to evaluate the combustion performance of surface materials under full-scale room fire conditions. Based on the oxygen consumption principle, it follows the GB/T 25207-2010 standard, which refers to ISO 9705. You can simulate a realistic corner fire scenario with actual installation conditions for the test samples, providing the most reliable assessment of flame spread, smoke production, and heat release rate. This apparatus is widely used in fire science research and for materials that cannot be accurately assessed using small-scale tests.

Application

You can use this apparatus in the following scenarios:

Full-scale fire performance evaluation: Assess the fire behavior of wall and ceiling materials installed as in real applications.

Research and development: Study flame spread, smoke generation, and heat release of construction and decorative materials.

Fire safety certification: Evaluate materials for compliance with building codes and international fire safety standards.

Academic and scientific research: Investigate fire dynamics and corner fire phenomena that small-scale tests cannot replicate.

Compatible test components: Combustion chamber, smoke and sample gas collection system, gas analysis and data processing system, fuel supply system, sand-box burner.

Standards

This test apparatus conforms to a range of international and national standards:

GB/T 27904:2011 — Test method for flame spread of interior decoration materials

GB/T 25207:2010 — Classification of fire performance of building decorative materials

GB 8624:2012 — Classification of the burning behavior of building materials and products

ISO 9705:2016 — Full-scale room corner test for building materials

DS/ISO/TR 9705‑2 — Room corner fire test Part 2: Guidelines for material performance assessment

Parameters

ParameterSpecification
Combustion Chamber Size 2.4 m (L) × 3.6 m (H) × 2.4 m (W)
Smoke Hood Size 3 m (W) × 3 m (D) × 1 m (H)
Weight 700 kg
Sand-box Burner Corner installation with 4–8 mm gravel and 2–3 mm sand, top surface flush with burner edge
Burner Ignition Surface ignition (no electric spark)
Maximum Heat Output 300 kW
Mass Flow Controller Range 0–7 g/s, accuracy ≤1.5%
Smoke Sampling Flow ≥13 L/min (diaphragm pump)
Optical Measurement Range 400–750 nm, transmissivity accuracy 0.01%
Pressure Measurement ±200 Pa, sensor response ≤1 s
Oxygen Analysis Paramagnetic, 16–21% (V/V), response ≤12 s
Carbon Dioxide Analysis IR type, 0–10% CO2. linearity ≤1%, response ≤12 s
Data Recording Interval 3 s per record
Environmental Requirements Power: 220V/10A, 380V/5KW; Temp: 10–35°C; Gas: propane, calibration gases: N2. CO2

Features

Complete system: Includes combustion chamber, smoke and sample gas collection, gas analysis and data processing, and fuel supply systems.

Precision smoke collection: Conical hood with mixing devices ensures uniform smoke sampling and accurate gas analysis.

High-capacity exhaust: Stainless steel centrifugal fan, temperature-resistant to 300°C, adjustable flow rate ≥3.5 m/s.

Accurate mass and gas flow measurement: Mass flow controllers for propane and air ensure precise heat output.

Advanced optical and gas analysis: Measures O2. CO2. smoke density, and visible light transmissivity with high accuracy.

Realistic fire simulation: Sand-box burner mimics corner fire conditions with adjustable heat output from 100 kW to 300 kW.

Safety protection: UV flame monitoring and automatic shutdown prevent system hazards.

Integrated data acquisition: Records temperature, pressure, smoke density, and gas concentration in real time; includes software for calibration, analysis, and report generation.

Accessories

Combustion chamber with corner sand-box burner

Smoke collection hood and stainless steel ducting with mixing devices

Gas analysis system (O2 and CO2 analyzers)

Data acquisition and processing system with computer and printer

Mass flow controllers and calibration gases (N2. CO2)

Optical measurement system and thermocouples

Pressure sensors and smoke density measurement system

Test Procedures

Install materials in the combustion chamber according to their real-life application layout.

Connect propane fuel and calibration gases, and ensure all sensors and measurement devices are operational.

Ignite the sand-box burner and control gas flow to produce 100 kW heat output for the first 10 minutes.

If no flashover occurs, increase heat output to 300 kW and continue for another 10 minutes.

Monitor flame spread, heat release rate, smoke production, and oxygen/CO2 levels in real time.

Stop the test immediately upon observing flashover or after the 20-minute test period.

Analyze and export results using the integrated software.

Maintenance Information

Inspect and clean the combustion chamber, sand-box burner, and exhaust ducts regularly.

Calibrate O2 and CO2 analyzers, optical systems, and mass flow controllers periodically.

Check thermocouples, pressure sensors, and smoke sampling systems before each test.

Ensure exhaust fans and ducting are free of obstructions and capable of continuous operation.

Store propane and calibration gases according to safety regulations, and maintain ambient temperature within 10–35°C.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Aircraft Seat Cushion Fuel Burn Test System,Aircraft interior fire safety test rig
Aircraft Seat Cushion Fuel Burn Test System,Aircraft interior fire safety test rig Whats/App: +86 156 1874 6768 Web: standard-groups.com The Aircraft Seat Cushion Fuel Burn Test System is a dedicated aviation fire testing platfo...
Spray Aerosol Ignition Distance Tester
Spray Aerosol Ignition Distance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to UN Recommendations on the Transportation of Dangerous Good...
Automatic Catheter Hydraulic Leakage Tester device
Automatic Catheter Hydraulic Leakage Tester device Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 15812.1: Disposable sterile catheters - Part 1: General requirements Featu...
Solid split-type weighted dummy for load simulation testing
Solid split-type weighted dummy for load simulation testing Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Solid Split-Type Weighted Dummyis a premium, high-stability ballast syste...
Vacuum Tribometer
Vacuum Tribometer Whats/App: +86 156 1874 6768 Web: standard-groups.com Vacuum Friction and Wear Tester is a specialized tribological testing system designed to st...
Все товары поставщика

Похожие товары

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Продавец: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Продавец: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...