Full-Scale Room Corner Fire Test Apparatus,Corner fire test rig for construction materials
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Full-Scale Room Corner Fire Test Apparatus is designed to evaluate the combustion performance of surface materials under full-scale room fire conditions. Based on the oxygen consumption principle, it follows the GB/T 25207-2010 standard, which refers to ISO 9705. You can simulate a realistic corner fire scenario with actual installation conditions for the test samples, providing the most reliable assessment of flame spread, smoke production, and heat release rate. This apparatus is widely used in fire science research and for materials that cannot be accurately assessed using small-scale tests.
Application
You can use this apparatus in the following scenarios:
Full-scale fire performance evaluation: Assess the fire behavior of wall and ceiling materials installed as in real applications.
Research and development: Study flame spread, smoke generation, and heat release of construction and decorative materials.
Fire safety certification: Evaluate materials for compliance with building codes and international fire safety standards.
Academic and scientific research: Investigate fire dynamics and corner fire phenomena that small-scale tests cannot replicate.
Compatible test components: Combustion chamber, smoke and sample gas collection system, gas analysis and data processing system, fuel supply system, sand-box burner.
Standards
This test apparatus conforms to a range of international and national standards:
GB/T 27904:2011 — Test method for flame spread of interior decoration materials
GB/T 25207:2010 — Classification of fire performance of building decorative materials
GB 8624:2012 — Classification of the burning behavior of building materials and products
ISO 9705:2016 — Full-scale room corner test for building materials
DS/ISO/TR 9705‑2 — Room corner fire test Part 2: Guidelines for material performance assessment
Parameters
| Parameter | Specification |
|---|---|
| Combustion Chamber Size | 2.4 m (L) × 3.6 m (H) × 2.4 m (W) |
| Smoke Hood Size | 3 m (W) × 3 m (D) × 1 m (H) |
| Weight | 700 kg |
| Sand-box Burner | Corner installation with 4–8 mm gravel and 2–3 mm sand, top surface flush with burner edge |
| Burner Ignition | Surface ignition (no electric spark) |
| Maximum Heat Output | 300 kW |
| Mass Flow Controller Range | 0–7 g/s, accuracy ≤1.5% |
| Smoke Sampling Flow | ≥13 L/min (diaphragm pump) |
| Optical Measurement Range | 400–750 nm, transmissivity accuracy 0.01% |
| Pressure Measurement | ±200 Pa, sensor response ≤1 s |
| Oxygen Analysis | Paramagnetic, 16–21% (V/V), response ≤12 s |
| Carbon Dioxide Analysis | IR type, 0–10% CO2. linearity ≤1%, response ≤12 s |
| Data Recording Interval | 3 s per record |
| Environmental Requirements | Power: 220V/10A, 380V/5KW; Temp: 10–35°C; Gas: propane, calibration gases: N2. CO2 |
Features
Complete system: Includes combustion chamber, smoke and sample gas collection, gas analysis and data processing, and fuel supply systems.
Precision smoke collection: Conical hood with mixing devices ensures uniform smoke sampling and accurate gas analysis.
High-capacity exhaust: Stainless steel centrifugal fan, temperature-resistant to 300°C, adjustable flow rate ≥3.5 m/s.
Accurate mass and gas flow measurement: Mass flow controllers for propane and air ensure precise heat output.
Advanced optical and gas analysis: Measures O2. CO2. smoke density, and visible light transmissivity with high accuracy.
Realistic fire simulation: Sand-box burner mimics corner fire conditions with adjustable heat output from 100 kW to 300 kW.
Safety protection: UV flame monitoring and automatic shutdown prevent system hazards.
Integrated data acquisition: Records temperature, pressure, smoke density, and gas concentration in real time; includes software for calibration, analysis, and report generation.
Accessories
Combustion chamber with corner sand-box burner
Smoke collection hood and stainless steel ducting with mixing devices
Gas analysis system (O2 and CO2 analyzers)
Data acquisition and processing system with computer and printer
Mass flow controllers and calibration gases (N2. CO2)
Optical measurement system and thermocouples
Pressure sensors and smoke density measurement system
Test Procedures
Install materials in the combustion chamber according to their real-life application layout.
Connect propane fuel and calibration gases, and ensure all sensors and measurement devices are operational.
Ignite the sand-box burner and control gas flow to produce 100 kW heat output for the first 10 minutes.
If no flashover occurs, increase heat output to 300 kW and continue for another 10 minutes.
Monitor flame spread, heat release rate, smoke production, and oxygen/CO2 levels in real time.
Stop the test immediately upon observing flashover or after the 20-minute test period.
Analyze and export results using the integrated software.
Maintenance Information
Inspect and clean the combustion chamber, sand-box burner, and exhaust ducts regularly.
Calibrate O2 and CO2 analyzers, optical systems, and mass flow controllers periodically.
Check thermocouples, pressure sensors, and smoke sampling systems before each test.
Ensure exhaust fans and ducting are free of obstructions and capable of continuous operation.
Store propane and calibration gases according to safety regulations, and maintain ambient temperature within 10–35°C.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Protective Clothing Flame Spread Test Machine | The tester is used for flame spread test of protective clothing. It is designed and manufactured according to ISO 15025 Standard for Protective Clo... | |
| Measuring devices for nanoindentation | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Measuring hardness and elastic modulus of thin films, coatings, and composite... | |
| Sun Protection Factor Tester(UV proof tester) | Introduction: The sun protection factor tester is is also aUV proof tester,mainly used to test and analyze sunscreen products. The instrument can ... | |
| Qinsun UV-master | Whats/App: +86 156 1874 6768 Web: standard-groups.com In response to the climate resistance testing requirements for outdoor textiles, this equ... | |
| Metal Wire Repeated Bending Tester | The Metal Wire Repeated Bending Tester is designed to evaluate the bending fatigue performance of metal wires under repeated stress. It measures th... |
Похожие товары
| SUGA SX75 super xenon weather meter supplier | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA SX75 7.5kW Super Xenon... | |
| UV & Carbon Arc Light Exposure Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chambe... | |
| Acid corrosion resistance cabinet for toilets | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric ac... | |
| Automated Filter Porosity Testing System | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Determining pore size di... | |
| Spray Aerosol Ignition Distance Tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Spray Aerosol Ignition Dist... |
















