Gas Turbine Filter Test System,gas turbine filter pressure drop and efficiency tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Test System for testing air intake filter systems for rotary machinery (ISO 29461). The test system for testing air intake filter systems for rotary machinery is based on the well-established filter test system for general air filters (ISO 16890) and extended to fulfil the specifications of ISO 29461.

It was developed with the aim of testing filters with different shapes (filter cartridges, cassette filter, filter with filter bags and plane filter media) using varying test aerosols (salt, oil) under adjustable air conditions (air humidity, temperature) within the test duct. By using the test system the following filter characteristics can be determined: differential pressure curves, dust holding capacity, gravimetric efficiency, fractional efficiency, salt removal efficiency (ISO/AWI 29461-4) and water endurance (ISO 29461-2).

Applications

Testing of gas turbine intake filter systems according to ISO 29461-2 and ISO/AWI 29461-4

Testing of general air filters (ISO 16890. EN 779. ASHRAE 52.2)

Standards

The system complies with:

(1) ISO 29461-1 – Air filter performance, test methods.

(2) ISO 29461-2 – Air filter performance, gas adsorption test.

(3) ISO/AWI 29461-4 – Air filter performance, salt removal efficiency.

(4) ISO 16890-2 – Air filter classification and testing for general air filters.

(5) ISO 16890-3 – Gravimetric efficiency determination.

(6) ISO 16890-4 – Fractional efficiency and dust holding capacity.

(7) ISO/DIS 29461-7 – Gas turbine filter testing guidance.

(8) ISO 12103-1 – Fine test dust (A2) for filter performance.

(9) ASHRAE 52.2 – Air filter testing using airflow and particle size distribution.

(10) EN 779 – Requirements for high-efficiency air filters.

(11) GB/T 12103-1 & GB/T 12103-2 – Test dust and adsorption methods.

(12) GB/T 18801-2015 – Performance testing for air purifiers.

Principle

A defined volume flow rate is sucked through a HEPA intake filter, the attached test duct and the safety filter. The test system is composed of 6 sections: aerosol inlet, upstream measurement, specimen holder, downstream measurement, safety filter and flow rate measurement. The measurement sections are equipped with ports for the aerosol characterization and the determination of the pressure drop.

Technical data

ParameterUnitValue
Test flow rate m³/h 800 … 11.000
Test aerosol DEHS, KCl, Ashrae, ISO 12103-A2 (AC fine), ISO 12103-A4 (AC coarse)
Test specimen dimensions 610 × 610 mm (pocket and cassette filters); diameter ≤ 400 mm, length ≤ 1500 mm (filter cartridges)
Differential pressure of test specimen Pa max. 2000
Compressed air supply (operating gas/air) bar min. 5 (17 m³/h)
Water supply (operating medium) bar min. 3
Power supply 3 × 400 VAC, 125 A, 50 Hz
Air circulation % 0 … 100
Sensors (others) Temperature, relative humidity, air pressure
System dimensions (W × H × D) m 4.6 × 1.7 × 14.0

Features

Circulation mode for control of the test parameters temperature and humidity

Injection of different aerosols (NaCl, KCl, DEHS) into an optimal flow profile

Automated feeding of water droplets and supersaturated vapour

High level of automation, mostly automated test runs with complete operator guiding

Gas-Tight Test Ducts: Ensure accurate particle and gas measurements.

Modular Design: Accommodates different filter types and sizes.

High Automation: Software-driven sequences with automatic data acquisition.

Multi-Medium Testing: Supports various aerosols and pollutant gases.

Standardized Reporting: Automatically generates reports including differential pressure, dust loading, fractional efficiency, and salt removal efficiency.

Environmental Control: Built-in temperature and humidity sensors allow testing under controlled conditions.

Accessories

Accessory / ConsumableQuantityDescription
DEHS Aerosol Generator 1 For fine aerosol particle testing
ASHRAE Dust Generator 1 For standardized dust loading tests
Optical Particle Counters 2 0.2–10 μm, four channels
H14 Air Filter 1 For system calibration
Temperature & Humidity Sensors 2 Monitor test environment
Gas Analyzers 3 Measure NO₂, H₂SO₄, and other gases

Operation Instructions

Safety:

Confirm power, gas, and water connections before testing.

Avoid direct exposure to aerosols and gases; ensure good ventilation.

Wear protective equipment when handling hazardous gases.

Standard-Specific Testing:

The system adjusts test conditions automatically according to ISO 16890. ISO 29461-2. or other relevant standards.

After testing, the system generates standardized reports.

Test Procedure

Preparation:

Select the appropriate filter adapter and install the sample.

Configure test airflow, aerosol concentration, humidity, and temperature per standard requirements.

Testing:

Start the automated system; aerosol and gas injection begins.

The system continuously records differential pressure, dust loading, and fractional efficiency.

Data Analysis & Reporting:

After testing, the software analyzes collected data.

Generate reports including pressure curves, dust loading, fractional efficiency, and salt removal efficiency.

Maintenance Information

Regularly inspect aerosol and gas generators for proper operation.

Calibrate sensors periodically for accuracy.

Keep the system clean and free of particulate build-up.

Ensure all safety interlocks and ventilation systems are functional.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Sanitary Napkin Absorption Speed Tester
Sanitary Napkin Absorption Speed Tester The Sanitary Napkin Absorption Speed Tester is designed to measure the absorption speed of sanitary napkins, menstrual pads, diapers, and other abs...
Plastic ball indentation hardness tester
Plastic ball indentation hardness tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Meet the standard: JTG E50 T1143-2006.SL/T.JT/T 521- Appendix A-2004.JTS-206-1- Appendix B...
Initial Adhesion Tester
Initial Adhesion Tester The initial - tack tester, also known as the initial - tack property tester or adhesive tape tackiness tester, is an instrument specifically used t...
Custom Medical injection needle rigidity tester
Custom Medical injection needle rigidity tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for rigidity testing of medical injection needles in th...
Cleveland Open Cup Flash Point Tester
Cleveland Open Cup Flash Point Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automatic Cleveland Open Cup Flash Point Analyzer is the latest addition to the Koehler...
Все товары поставщика

Похожие товары

Surface adhesion testing equipment factory price
Surface adhesion testing equipment factory price Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards JIS L 1066 (Testing Methods fo...
Continuous load scratch resistance tester manufacturer
Continuous load scratch resistance tester manufacturer Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO DIS 12137-2 (Plastics &mda...
High precision continuous load surface tester
High precision continuous load surface tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Multi-function surface performance test system
Multi-function surface performance test system Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...
Laboratory tribology research equipment
Laboratory tribology research equipment Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for...