Toilet Corrosion Test Chamber (HCl and Ammonia),acid exposure cabinet for bathroom ware

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Toilet Corrosion Test Chamber (HCl and Ammonia) is used to evaluate the rust resistance of toilet products to detergents and urine, meeting the corrosion testing requirements of GB/T 4706.53-2024 and IEC 60335-2-84:2019 standards. This equipment simulates an ammonia and hydrochloric acid environment to conduct a 96-hour corrosion test on the toilet, ensuring its continued normal operation under harsh conditions. Key technical parameters include test chamber dimensions, temperature, and gas concentration, and it is equipped with appropriate safety and sealing measures.

Applications

Toilet seat hydrochloric acid and ammonia corrosion tester is used for testing to evaluate the ability of toilet seat products to provide adequate rust protection against detergents and urine. The test chamber by simulating ammonia components, hydrochloric acid solvent body, medium on the toilet electrical components or other inorganic cover layer in condensation conditions of corrosion test. The test chamber is electronic toilet sampling and testing of product quality supervision and inspection institute 3 testing organizations and toilet manufacturers of essential test equipment.

Standards

GB/T 4706.53-2024: Safety of household and similar electrical appliances - Part 2: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

IEC 60335-2-84:2019: Household and similar electrical appliances - Safety - Part 2-84: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

Features

1. Precise and Controllable Corrosive Environment: It can stably maintain specific concentrations of ammonia (0.055%±0.005%) and hydrochloric acid (0.0005%±0.0002%), using a gas cylinder method for gas generation and a corrosion-resistant mass flow meter for flow control, ensuring precise matching of the corrosive medium concentration and flow rate to test requirements.

2. Standardized Test Conditions: It requires operation in a cleanroom environment without strong airflow. Temperature (25℃±2℃) and humidity (<75% RH) are strictly controlled to ensure the repeatability and reliability of test results.

3. Strong Sample Load Capacity Adaptability: The equipped sample test rack has a maximum load capacity of ≥50kg and can maintain a vertical placement at 90°±2°, adapting to the fixing requirements of large items such as toilet seats.

4. Reasonable structural dimensions: The inner casing (W1200×H1200×D1200mm) is large enough to accommodate a toilet, while the outer casing (approximately W2350×H1700×D1500mm) balances operating space with equipment integration.

5. Low operating energy consumption: The installed power is only 400W, and it is compatible with AC 220V universal power supplies, resulting in high cost and environmental adaptability.

Technical Parameters

No.Main ParametersSpecifications
1 Inner box size W1200×H1200×D1200mm
2 Outer box size About W2350×H1700×D1500mm
3 Test temperature Room temperature
4 Ammonia concentration 0.055%±0.005
5 Hydrochloric acid concentration 0.0005%±0.0002
6 Test gas generation method Cylinder method
7 Test gas control Calculate by volume ratio (per test requirements), then control flow rate via anticorrosive mass flow meter
8 Sample test frame Maximum load ≥50kg; placed vertically at 90°±2°
9 Use environment & temperature Clean room (no strong airflow); temperature 25℃±2℃
10 Use environmental humidity <75% RH
11 Equipment power supply AC 220V 50/60Hz
12 Installed power 400W

Accessoriess

1. Hydrochloric acid and ammonia corrosion test chamber 1 set

2. A set of exhaust gas filtering device

3. ammonia gas cylinder 1 bottle

4. Matching special pressure reducing valve 1pc

5.1 bottle of hydrochloric acid

Test Procedures

The following tests shall be performed on the toilet samples, except where the electrical components are in a closed state or where they are unlikely to be exposed to the polluted environment.

Place the toilet sample in an indoor atmosphere with an ammonia gas volume fraction of (0.055 ± 0.005)% for 96 hours.

Then place the toilet sample in an indoor atmosphere with a hydrochloric acid volume fraction of (0.0005 ± 0.0002)% for 96 hours.

After the tests, the toilet sample should not exhibit any damage that would result in non-compliance with GB/T 4706.53-2024 or IEC 60335-2-84:2019 standards.


Отправить запрос, связаться с поставщиком

Кому: Standard International Group (HK) Limited
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Cloud-based dust ignition temperature logger
Cloud-based dust ignition temperature logger Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. Chemical Industry: Determine the Material Effects (MI) of chemical dusts s...
Syringe needle flow tester
Syringe needle flow tester The Syringe Needle Flow Tester is designed to evaluate the flow characteristics of syringes by measuring the volume of liquid discharged over a spe...
Oxygen Index Test Apparatus,Accurate fire resistance testing instruments
Oxygen Index Test Apparatus,Accurate fire resistance testing instruments TestingStandards: ISO4589-2.ASTMD2863.GB/T2406.GB/T5454 Applications: ThisOxygen Index Testerisusedtodeterminethelowestoxygendensitythattestedma...
Injection device slide tester for plunger
Injection device slide tester for plunger Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for evaluating the sliding performance of various medi...
UV & Carbon Arc Light Exposure Tester
UV & Carbon Arc Light Exposure Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chamber employs alternating current to ignite carbon rod...
Все товары поставщика

Похожие товары

SUGA SX75 super xenon weather meter supplier
SUGA SX75 super xenon weather meter supplier Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications SUGA SX75 7.5kW Super Xenon...
UV & Carbon Arc Light Exposure Tester
UV & Carbon Arc Light Exposure Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Carbon Arc Aging Chambe...
Acid corrosion resistance cabinet for toilets
Acid corrosion resistance cabinet for toilets Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Toilet seat hydrochloric ac...
Automated Filter Porosity Testing System
Automated Filter Porosity Testing System Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Determining pore size di...
Spray Aerosol Ignition Distance Tester
Spray Aerosol Ignition Distance Tester Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Spray Aerosol Ignition Dist...