Application
HVAC and Indoor Airflow Research: Study indoor airflow patterns, temperature distribution, and pollutant concentration under different ventilation strategies for research and teaching purposes.
Human Thermal Comfort Testing: Simulate real indoor conditions with various airflow organizations to compare thermal comfort under different ventilation scenarios.
Electronics and Component Reliability: Evaluate products, parts, and materials in real airflow conditions to assess operational reliability and performance.
Medical and Military Studies: Research cross-infection and aerosol transmission under different air circulation conditions within controlled indoor environments.
Standards
Internal compliance with laboratory safety, electrical, and environmental simulation standards.
Air exchange rates, temperature, and humidity control meet industrial and research-grade environmental chamber specifications.
Custom configurations may comply with client-specific ventilation or airflow standards.
Parameters
| No. | Item | Technical Specifications |
|---|---|---|
| 1 | Chamber Dimensions | External: 5.1 m (L) × 5.6 m (W) × 3.2 m (H) Internal: 4.9 m (L) × 5.4 m (W) × 2.6 m (H) Standard insulated door: 0.8 m × 2.0 m with double-glass observation window Internal lighting: 1 daylight lamp; power outlet: 2.5 kW Digital display panel for temperature and humidity Optional additional window available at extra cost |
| 2 | Temperature Range | 10–40°C ±0.5°C adjustable |
| 3 | Humidity Range | 35–90% ±5% adjustable |
| 4 | Air Change Rate | 3–16 ACH; optional single-pass fresh air supply available (installation-dependent, extra cost) |
| 5 | Electrical Control System | Centralized control panel; Supply: AC 380V/50Hz, max power ≤28.5 kW; Equipped with short-circuit and over-temperature protection |
| 6 | Airflow Organization Modes | 9 modes: Mixed Ventilation:(1) Top diffuser with side-lower return, (2) Side supply-side return, (3) Side supply-top return Displacement Ventilation:(1) Top return, (2) Side-top return Floor Ventilation:(1) Top return, (2) Side-top return Stratified Ventilation:(1) Top return, (2) Side-lower return Optional quick-connect supply fittings available (extra cost) |
| 7 | Working Environment | Standard laboratory conditions |
| 8 | Other Requirements | Refrigeration unit piping and electrical lines default 5 m; site preparation including leveling, wall openings, rain shelter, water supply, drainage, and main power line to control box to be provided by user; chamber panels: 100 mm PU double-color steel |
| 9 | Special Notes | Default specifications are factory standards; custom requirements exceeding these parameters require additional consultation and pricing |
Features
High-Precision Environmental Control: Maintains stable temperature and humidity with ±0.5°C and ±5% RH accuracy.
Multiple Airflow Modes: Supports mixed, displacement, floor, and stratified ventilation with nine programmable configurations.
Observation and Monitoring: Equipped with observation window, internal lighting, and digital panel for real-time monitoring of chamber conditions.
Customizable Ventilation: Air change rates adjustable; optional quick-connect fittings allow flexible supply modifications.
Safety and Reliability: Electrical protections including short-circuit and over-temperature safeguards.
Modular Installation Support: Refrigeration, water, drainage, and power line preparation allow smooth on-site assembly.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Metal Corrosivity Tester | The Metal Corrosivity Tester is used to determine the corrosivity of liquids and solids that may become liquid during transport. It conforms to the... | |
| Automated white light interferometry system | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The White Light Interferometer is widely used for non-contact surface topograp... | |
| Vacuum Ball - Disk Friction Tester | A vacuum ball-on-disk friction tester is a device used to simulate friction and wear behavior under actual operating conditions, in order to evalua... | |
| Cartridge Dynamic Cycle Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 23840 — Hydraulic fluid power — Filters — Evaluation o... | |
| Laboratory tribology research equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for Wear Resistance of Metal Surfaces GB/T 17657-202... |
Похожие товары
| Surface adhesion testing equipment factory price | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards JIS L 1066 (Testing Methods fo... | |
| Continuous load scratch resistance tester manufacturer | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO DIS 12137-2 (Plastics &mda... | |
| High precision continuous load surface tester | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... | |
| Multi-function surface performance test system | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... | |
| Laboratory tribology research equipment | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 6040-2008 Test Method for... |