Glove Thermal Insulation Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The tester complies with and supports testing according to:
BS 6526:2002 – Household Oven Gloves Specification and Test Methods
ISO 12127 – Protective Gloves for Thermal Hazards (Reference Method)
EN 407 – Protective Gloves Against Thermal Risks
ASTM F1060 – Standard Test Method for Thermal Insulation of Materials
ISO 188 – Rubber, Vulcanized or Thermoplastic – Accelerated Ageing and Heat Resistance
Parameters
| Parameter | Specification |
|---|---|
| Sample Size | Diameter 70 mm |
| Temperature Range | Room Temp +5°C to 180°C |
| Temperature Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Polyethylene Sample Mounting Plate | 120 × 120 × 25 mm |
| Mounting Plate Sensor Range | 0–260°C, ±0.1% |
| Heating Block Sensor Range | 0–260°C, ±0.1% |
| Brass Cylinder Weight | 3000 ±10 g |
| Brass Cylinder Dimensions | Small end Φ32 ±0.02 mm H20 ±0.05 mm; Large end Φ76 ±0.02 mm H74 ±0.05 mm |
| Sensor Detection Point | 2.5 mm ±0.05 mm from cylinder base |
| Cylinder Drop Speed | 25 mm/s (adjustable 1–60 mm/s) |
| Cylinder Return Speed | 25 mm/s (adjustable 1–60 mm/s) |
| Distance from Cylinder to Sample | 100 mm ±0.5 mm |
| Polyethylene Protective Plate | 200 × 250 × 15 mm |
| Protective Plate Distance to Sample Surface | 50 mm |
| Protective Plate Movement Speed | 80 mm/s |
| Time Measurement Range | 0–99999.9 s |
| Power Supply | AC 220V, 50Hz |
| Dimensions (L×W×H) | 540 × 380 × 500 mm |
| Total Weight | 40 kg |
Features
Color touchscreen with Chinese/English interface and menu-driven operation
Core control via STMicroelectronics 32-bit multifunction mainboard with 16-bit high-precision AD temperature acquisition
Servo motor and servo controller for precise motion control
Real-time data display on connected PC, with automatic curve plotting
Automatic generation of test reports
Brass cylinder drops under gravity for controlled contact
Automatic cylinder return mechanism
Automatic movement and return of thermal protective plate
High-precision Omega sensors and transmitters for accurate temperature measurement
Test Procedures
Preparation
Sample Preparation: Fix the glove onto the test fixture, ensuring the sample diameter meets the standard (typically 70 mm).
Equipment Check: Verify power supply, sensors, and heating elements are functioning properly.
Operation
Place Sample: Position the glove on the polyethylene mounting plate equipped with thermocouples connected to the temperature recording device.
Heating Test: Lower the preheated brass cylinder onto the sample and measure the temperature rise over a set duration.
Record Data: Monitor and record the glove’s internal temperature in real-time to calculate thermal insulation performance.
Precautions
Safety: Ensure operators maintain a safe distance from high-temperature components to prevent burns.
Equipment Maintenance: Regularly inspect sensors and heating devices to maintain test accuracy and reliability.
Maintenance Information
Clean thermocouples, sensors, and brass surfaces regularly to prevent measurement errors.
Inspect servo motors and moving parts monthly for smooth operation.
Verify calibration of sensors periodically to ensure accurate temperature readings.
Check the HMI and PC interface functionality to maintain data integrity.
Ensure protective plates and cylinders move freely without obstruction.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Solid Split-Type Weighted Dummy Manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Solid Split-Type Weighted Dummyis a premium, high-stability ballast syste... | |
| Porton Thermal Manikin Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Porton-man Thermal Manikin is suitable for a wide range of applications, i... | |
| ASTM G99 Wide-Range Load Friction and Wear Testing Machine for Tribology Research | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Wide-Range Load Friction and Wear Testing Machine is a versatile tribolog... | |
| Solid Energetic Materials Stability Tester | ASTM E487 & EN 13763 | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards EN 13938-2:Respiratory Protective Equipment for Firefighters - Par... | |
| Composite Material Thermal Cycling Wet Freezing Characterization System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Thermal Cycle Wet Freezing Testing Machine is designed for comprehensive environmental ... |
Похожие товары
| Высокоскоростная экструзионная линия для производства гофрированных труб с двойными стенками из ПЭВП с водяным охлаждением | Продавец: Shandong HUASU Plastic Technology Co.,Ltd. | Формы имеют структуру с двойным каналом потока и фильерную головку, обработанную азотированием и ... | |
| PanEVAP & MVR system | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | Продавец: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |